12 resultados para Selenium
em Universit
Resumo:
BACKGROUND: Acute renal failure is a serious complication in critically ill patients and frequently requires renal replacement therapy, which alters trace element and vitamin metabolism. OBJECTIVE: The objective was to study trace element balances during continuous renal replacement therapy (CRRT) in intensive care patients. DESIGN: In a prospective randomized crossover trial, patients with acute renal failure received CRRT with either sodium bicarbonate (Bic) or sodium lactate (Lac) as a buffering agent over 2 consecutive 24-h periods. Copper, selenium, zinc, and thiamine were measured with highly sensitive analytic methods in plasma, replacement solutions, and effluent during 8-h periods. Balances were calculated as the difference between fluids administered and effluent losses and were compared with the recommended intakes (RI) from parenteral nutrition. RESULTS: Nineteen sessions were conducted in 11 patients aged 65 +/- 10 y. Baseline plasma concentrations of copper were normal, whereas those of selenium and zinc were below reference ranges; glutathione peroxidase was in the lower range of normal. The replacement solutions contained no detectable copper, 0.01 micromol Se/L (Bic and Lac), and 1.42 (Bic) and 0.85 (Lac) micromol Zn/L. Micronutrients were detectable in all effluents, and losses were stable in each patient; no significant differences were found between the Bic and Lac groups. The 24-h balances were negative for selenium (-0.97 micromol, or 2 times the daily RI), copper (-6.54 micromol, or 0.3 times the daily RI), and thiamine (-4.12 mg, or 1.5 times the RI) and modestly positive for zinc (20.7 micromol, or 0.2 times the RI). CONCLUSIONS: CRRT results in significant losses and negative balances of selenium, copper, and thiamine, which contribute to low plasma concentrations. Prolonged CRRT is likely to result in selenium and thiamine depletion despite supplementation at recommended amounts.
Resumo:
To investigate the trace elements (TE) losses and status after trauma, 11 severely injured patients (Injury Severity Score: 29 +/- 6), admitted to the ICU were studied from the day of injury (D0) until D25. Balance studies were started within 24 hours after injury, until D7. Serum and urine samples were collected from D1 to D7, then on D10, 15, 20, and 25. Intravenous TE supplementation was initiated upon admission. SERUM: Selenium (Se) and zinc (Zn) levels were decreased until D7 and were normal thereafter. LOSSES: TE urinary excretions were higher than reference ranges until D20 in all patients. Fluid losses through drains contained large amounts of TE. BALANCES: Balances were slightly positive for copper (Cu) and Zn, and negative for Se from D5 to D7 despite supplements. Cu status exhibited minor changes compared to those observed with the Zn and Se status: Serum levels were decreased and losses increased. Considering the importance of Se and Zn in free radical scavenging, anabolism, and immunity, current recommendations for TE supplements in severely traumatized patients ought to be revised.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
INTRODUCTION: Oxidative stress is involved in the development of secondary tissue damage and organ failure. Micronutrients contributing to the antioxidant (AOX) defense exhibit low plasma levels during critical illness. The aim of this study was to investigate the impact of early AOX micronutrients on clinical outcome in intensive care unit (ICU) patients with conditions characterized by oxidative stress. METHODS: We conducted a prospective, randomized, double-blind, placebo-controlled, single-center trial in patients admitted to a university hospital ICU with organ failure after complicated cardiac surgery, major trauma, or subarachnoid hemorrhage. Stratification by diagnosis was performed before randomization. The intervention was intravenous supplements for 5 days (selenium 270 microg, zinc 30 mg, vitamin C 1.1 g, and vitamin B1 100 mg) with a double-loading dose on days 1 and 2 or placebo. RESULTS: Two hundred patients were included (102 AOX and 98 placebo). While age and gender did not differ, brain injury was more severe in the AOX trauma group (P = 0.019). Organ function endpoints did not differ: incidence of acute kidney failure and sequential organ failure assessment score decrease were similar (-3.2 +/- 3.2 versus -4.2 +/- 2.3 over the course of 5 days). Plasma concentrations of selenium, zinc, and glutathione peroxidase, low on admission, increased significantly to within normal values in the AOX group. C-reactive protein decreased faster in the AOX group (P = 0.039). Infectious complications did not differ. Length of hospital stay did not differ (16.5 versus 20 days), being shorter only in surviving AOX trauma patients (-10 days; P = 0.045). CONCLUSION: The AOX intervention did not reduce early organ dysfunction but significantly reduced the inflammatory response in cardiac surgery and trauma patients, which may prove beneficial in conditions with an intense inflammation. TRIALS REGISTRATION: Clinical Trials.gov RCT Register: NCT00515736.
Resumo:
OBJECTIVE: Enteral glutamine supplementation and antioxidants have been shown to be beneficial in some categories of critically ill patients. This study investigated the impact on organ function and clinical outcome of an enteral solution enriched with glutamine and antioxidant micronutrients in patients with trauma and with burns. METHODS: This was a prospective study of a historical control group including critically ill, burned and major trauma patients (n = 86, 40 patients with burns and 46 with trauma, 43 in each group) on admission to an intensive care unit in a university hospital (matching for severity, age, and sex). The intervention aimed to deliver a 500-mL enteral solution containing 30 g of glutamine per day, selenium, zinc, and vitamin E (Gln-AOX) for a maximum of 10 d, in addition to control treatment consisting of enteral nutrition in all patients and intravenous trace elements in all burn patients. RESULTS: Patients were comparable at baseline, except for more inhalation injuries in the burn-Gln-AOX group (P = 0.10) and greater neurologic impairment in the trauma-Gln-AOX group (P = 0.022). Intestinal tolerance was good. The full 500-mL dose was rarely delivered, resulting in a low mean glutamine daily dose (22 g for burn patients and 16 g for trauma patients). In burn patients intravenous trace element delivery was superior to the enteral dose. The evolution of the Sequential Organ Failure Assessment score and other outcome variables did not differ significantly between groups. C-reactive protein decreased faster in the Gln-AOX group. CONCLUSION: The Gln-AOX supplement was well tolerated in critically ill, injured patients, but did not improve outcome significantly. The delivery of glutamine below the 0.5-g/kg recommended dose in association with high intravenous trace element substitution doses in burn patients are likely to have blunted the impact by not reaching an efficient treatment dose. Further trials testing higher doses of Gln are required.
Resumo:
Infections remain the leading cause of death after major burns. Trace elements are involved in immunity and burn patients suffer acute trace element depletion after injury. In a previous nonrandomized study, trace element supplementation was associated with increased leukocyte counts and shortened hospital stays. This randomized, placebo-controlled trial studied clinical and immune effects of trace element supplements. Twenty patients, aged 40 +/- 16 y (mean +/- SD), burned on 48 +/- 17% of their body surfaces, were studied for 30 d after injury. They consumed either standard trace element intakes plus supplements (40.4 micromol Cu, 2.9 micromol Se, and 406 micromol Zn; group TE) or standard trace element intakes plus placebo (20 micromol Cu, 0.4 micromol Se, and 100 micromol Zn; group C) for 8 d. Demographic data were similar for both groups. Mean plasma copper and zinc concentrations were below normal until days 20 and 15, respectively (NS). Plasma selenium remained normal for group TE but decreased for group C (P < 0.05 on days 1 and 5). Total leukocyte counts tended to be higher in group TE because of higher neutrophil counts. Proliferation to mitogens was depressed compared with healthy control subjects (NS). The number of infections per patient was significantly (P < 0.05) lower in group TE (1.9 +/- 0.9) than in group C (3.1 +/- 1.1) because of fewer pulmonary infections. Early trace element supplementation appears beneficial after major burns; it was associated with a significant decrease in the number of bronchopneumonia infections and with a shorter hospital stay when data were normalized for burn size.
Resumo:
Mild to moderate forms of orbitopathy are common in auto-immune thyroid diseases, whereas severe forms are rare. Euthyroidism restoration, no smoking, and ocular local lubricants are necessary for all the patients. In case of mild orbitopathy, treatment by selenium is now indicated. Active forms of thyroid orbitopathy are better treated by IV steroids. Surgery is indicated in optic neuropathy resistant to steroids and in sequellar forms of the disease.
Resumo:
BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.