3 resultados para wind turbine performance
em Université de Lausanne, Switzerland
Resumo:
INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.
Resumo:
Objective: Despite the importance of respiration and hyperventilation in anxiety disorders, research on breathing disturbances associated with hyperventilation is rare in the field of music performance anxiety (MPA, also known as stage fright). The only comparable study in this area reported a positive correlation between negative feelings of MPA and hyperventilation complaints during performance. The goals of this study were (a) to extend these previous findings to the period before performance, (b) to test whether a positive correlation also exists between hyperventilation complaints and the experience of stage fright as a problem, (c) to investigate instrument-specific symptom reporting, and (d) to confirm gender differences in negative feelings of MPA and hyperventilation complaints reported in other studies. Methods: We assessed 169 university students of classical music with a questionnaire comprising: the State-Trait Anxiety Inventory for negative feelings of MPA, the Nijmegen Questionnaire for hyperventilation complaints, and a single item for the experience of stage fright as a problem. Results: We found a significant positive correlation between hyperventilation complaints and negative feelings of MPA before performance and a significant positive correlation between hyperventilation complaints and the experience of stage fright as a problem. Wind musicians/singers reported a significantly higher frequency of respiratory symptoms than other musicians. Furthermore, women scored significantly higher on hyperventilation complaints and negative feelings of MPA. Conclusion: These results further the findings of previous reports by suggesting that breathing disturbances associated with hyperventilation may play a role in MPA prior to going on stage. Experimental studies are needed to confirm whether hyperventilation complaints associated with negative feelings of MPA manifest themselves at the physiological level. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE: To use measurement by cycling power meters (Pmes) to evaluate the accuracy of commonly used models for estimating uphill cycling power (Pest). Experiments were designed to explore the influence of wind speed and steepness of climb on accuracy of Pest. The authors hypothesized that the random error in Pest would be largely influenced by the windy conditions, the bias would be diminished in steeper climbs, and windy conditions would induce larger bias in Pest. METHODS: Sixteen well-trained cyclists performed 15 uphill-cycling trials (range: length 1.3-6.3 km, slope 4.4-10.7%) in a random order. Trials included different riding position in a group (lead or follow) and different wind speeds. Pmes was quantified using a power meter, and Pest was calculated with a methodology used by journalists reporting on the Tour de France. RESULTS: Overall, the difference between Pmes and Pest was -0.95% (95%CI: -10.4%, +8.5%) for all trials and 0.24% (-6.1%, +6.6%) in conditions without wind (<2 m/s). The relationship between percent slope and the error between Pest and Pmes were considered trivial. CONCLUSIONS: Aerodynamic drag (affected by wind velocity and orientation, frontal area, drafting, and speed) is the most confounding factor. The mean estimated values are close to the power-output values measured by power meters, but the random error is between ±6% and ±10%. Moreover, at the power outputs (>400 W) produced by professional riders, this error is likely to be higher. This observation calls into question the validity of releasing individual values without reporting the range of random errors.