41 resultados para visual world eye-tracking

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We previously reported that nuclear grade assignment of prostate carcinomas is subject to a cognitive bias induced by the tumor architecture. Here, we asked whether this bias is mediated by the non-conscious selection of nuclei that "match the expectation" induced by the inadvertent glance at the tumor architecture. 20 pathologists were asked to grade nuclei in high power fields of 20 prostate carcinomas displayed on a computer screen. Unknown to the pathologists, each carcinoma was shown twice, once before a background of a low grade, tubule-rich carcinoma and once before the background of a high grade, solid carcinoma. Eye tracking allowed to identify which nuclei the pathologists fixated during the 8 second projection period. For all 20 pathologists, nuclear grade assignment was significantly biased by tumor architecture. Pathologists tended to fixate on bigger, darker, and more irregular nuclei when those were projected before kigh grade, solid carcinomas than before low grade, tubule-rich carcinomas (and vice versa). However, the morphometric differences of the selected nuclei accounted for only 11% of the architecture-induced bias, suggesting that it can only to a small part be explained by the unconscious fixation on nuclei that "match the expectation". In conclusion, selection of « matching nuclei » represents an unconscious effort to vindicate the gravitation of nuclear grades towards the tumor architecture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Visual behavior is known to be atypical in Autism Spectrum Disorders (ASD). Monitor-based eye-tracking studies have measured several of these atypicalities in individuals with Autism. While atypical behaviors are known to be accentuated during natural interactions, few studies have been made on gaze behavior in natural interactions. In this study we focused on i) whether the findings done in laboratory settings are also visible in a naturalistic interaction; ii) whether new atypical elements appear when studying visual behavior across the whole field of view. METHODOLOGY/PRINCIPAL FINDINGS: Ten children with ASD and ten typically developing children participated in a dyadic interaction with an experimenter administering items from the Early Social Communication Scale (ESCS). The children wore a novel head-mounted eye-tracker, measuring gaze direction and presence of faces across the child's field of view. The analysis of gaze episodes to faces revealed that children with ASD looked significantly less and for shorter lapses of time at the experimenter. The analysis of gaze patterns across the child's field of view revealed that children with ASD looked downwards and made more extensive use of their lateral field of view when exploring the environment. CONCLUSIONS/SIGNIFICANCE: The data gathered in naturalistic settings confirm findings previously obtained only in monitor-based studies. Moreover, the study allowed to observe a generalized strategy of lateral gaze in children with ASD when they were looking at the objects in their environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation focuses on the strategies consumers use when making purchase decisions. It is organized in two main parts, one centering on descriptive and the other on applied decision making research. In the first part, a new process tracing tool called InterActive Process Tracing (IAPT) is pre- sented, which I developed to investigate the nature of consumers' decision strategies. This tool is a combination of several process tracing techniques, namely Active Information Search, Mouselab, and retrospective verbal protocol. To validate IAPT, two experiments on mobile phone purchase de- cisions were conducted where participants first repeatedly chose a mobile phone and then were asked to formalize their decision strategy so that it could be used to make choices for them. The choices made by the identified strategies correctly predicted the observed choices in 73% (Experiment 1) and 67% (Experiment 2) of the cases. Moreover, in Experiment 2, Mouselab and eye tracking were directly compared with respect to their impact on information search and strategy description. Only minor differences were found between these two methods. I conclude that IAPT is a useful research tool to identify choice strategies, and that using eye tracking technology did not increase its validity beyond that gained with Mouselab. In the second part, a prototype of a decision aid is introduced that was developed building in particular on the knowledge about consumers' decision strategies gained in Part I. This decision aid, which is called the InterActive Choice Aid (IACA), systematically assists consumers in their purchase decisions. To evaluate the prototype regarding its perceived utility, an experiment was conducted where IACA was compared to two other prototypes that were based on real-world consumer decision aids. All three prototypes differed in the number and type of tools they provided to facilitate the process of choosing, ranging from low (Amazon) to medium (Sunrise/dpreview) to high functionality (IACA). Overall, participants slightly preferred the prototype of medium functionality and this prototype was also rated best on the dimensions of understandability and ease of use. IACA was rated best regarding the two dimensions of ease of elimination and ease of comparison of alternatives. Moreover, participants choices were more in line with the normatively oriented weighted additive strategy when they used IACA than when they used the medium functionality prototype. The low functionality prototype was the least preferred overall. It is concluded that consumers can and will benefit from highly functional decision aids like IACA, but only when these systems are easy to understand and to use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives : Eye movements are necessary to stabilize the retinal picture and to find a new object. This seems useless for blind people, so why do they nevertheless have them. We report on an EOG study on 29 blind volunteers and 5 volunteers with closed eyes. Material and methods: We recorded eye movements by EOG and let the volunteers fulfill different exercises by following an acoustic running point by gaze, pointing, imagining in the room, listing words that begin with the vocal U and a finger labyrinth. Results: We found slow eye movements as well as pathological eye movements in the blind subjects. We found that blind subjects have a horizontal preferency.The duration of fixation of pictures is shorter in the blind subjects. The blind could even modulate saccade amplitudes . Discussion: Eye movements seem to be structural properties of the brain which prepare the organism for certain situations-even if they do not take place. We think that eye movements are partially independent of the experience of view. We did not expect that the blind subjects could modify gaze according to the subject. This leads to the hypothesis of a preformed dimensional system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Patients with schizophrenia show deficits in visuospatial working memory and visual pursuit processes. It is currently unclear, however, whether both impairments are related to a common neuropathological origin. The purpose of the present study was therefore to examine the possible relations between the encoding and the discrimination of dynamic visuospatial stimuli in schizophrenia. METHOD: Sixteen outpatients with schizophrenia and 16 control subjects were asked to encode complex disc displacements presented on a screen. After a delay, participants had to identify the previously presented disc trajectory from a choice of six static linear paths, among which were five incorrect paths. The precision of visual pursuit eye movements during the initial presentation of the dynamic stimulus was assessed. The fixations and scanning time in definite regions of the six paths presented during the discrimination phase were investigated. RESULTS: In comparison with controls, patients showed poorer task performance, reduced pursuit accuracy during incorrect trials and less time scanning the correct stimulus or the incorrect paths approximating its global structure. Patients also spent less time scanning the leftmost portion of the correct path even when making a correct choice. The accuracy of visual pursuit and head movements, however, was not correlated with task performance. CONCLUSIONS: The present study provides direct support for the hypothesis that active integration of visuospatial information within working memory is deficient in schizophrenia. In contrast, a general impairment of oculomotor mechanisms involved in smooth pursuit did not appear to be directly related to lower visuospatial working memory performance in schizophrenia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Optic perineuritis is an uncommon variety of orbital inflammatory disease that is distinct from demyelinating optic neuritis. OBJECTIVE: To describe the clinical and radiographic features of idiopathic optic perineuritis, with particular emphasis on those features that help to distinguish this condition from optic neuritis. METHODS: We reviewed the medical records of 14 patients with optic perineuritis who were seen in 2 neuro-ophthalmology clinics. RESULTS: Patients ranged in age from 24 to 60 years; 5 were older than 50 years. All patients had visual loss, eye pain, or both. The visual acuity was 20/20 or better in 8 of the 15 eyes. The results of visual field testing were normal in 2 eyes, and a paracentral scotoma or an arcuate defect was seen in 7. Magnetic resonance imaging scans demonstrated circumferential enhancement around the optic nerve, sometimes with intraorbital extension. Response to corticosteroids was dramatic; however, 4 patients had a relapse with lowering of the dose. CONCLUSIONS: In contrast to those with optic neuritis, patients with optic perineuritis are often older at onset and are more likely to show sparing of central vision. Magnetic resonance imaging scans demonstrate enhancement around, rather than within, the optic nerve. Response to corticosteroids is more dramatic than in patients with optic neuritis, and patients are more likely to experience recurrence after stopping treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Les Echelles Lausannoises d'Auto-Evaluation des Difficultés et des Besoins ELADEB, est un outil utilisé en réhabilitation psychiatrique permettant de dresser le profil des problèmes rencontrés par les patients psychiatriques dans les principaux domaines de la vie quotidienne, ainsi que le besoin d'aide supplémentaire à celle déjà existante. Cet outil a déjà été validé dans une étude1 portant sur 94 patients et recueille un intérêt grandissant. Afin de compléter les données de validation recueillies lors de la première étude, nous présentons ici une seconde étude visant à comprendre d'avantage cet outil en le couplant à l'Eye tracker qui permet une étude du regard et ainsi observer des phénomènes visuels des sujets qui pratiquent l'auto-évaluation des difficultés et des besoins d'aide. Objectifs Cette étude pilote et exploratrice a pour but de mesurer l'exploration visuelle des cartes lors de l'évaluation d'ELADEB au travers des trois variables suivantes d'oculométrie récoltées au travers de l'outil de mesure de l'Eye tracker : (1) la variation de la taille pupillaire (pixels), (2) le rapport des nombres de points de fixation/temps, et (3) de la durée totale du temps de traitement de l'information de la carte (ms). Hypothèses. Le traitement visuel des cartes sélectionnées comme problèmes versus non problèmes sera différent chez tout le monde d'une part au niveau de : (1) la variation pupillaire, (2) du nombre de points de fixation de l'oeil/temps ainsi que (3) de la durée totale du traitement de l'information de la carte en fonction de notre compréhension. On peut poser l'hypothèse que l'émotion sera différente selon que la personne rencontre un problème ou non et ainsi, on peut s'attendre à ce que les cartes sélectionnées comme problèmes soient associées à une réaction émotionnelle plus importante que les autres, ce qui nous permettrait d'observer une corrélation entre le balayage visuel et ELADEB. Méthodes Cette étude exploratoire porte sur un échantillon de 10 sujets passant un test d'évaluation des difficultés et des besoins ELADEB, couplé à un appareil d'Eye tracking. Les critères d'inclusion des sujets sont : (1) hommes entre 30 et 40 ans, (2) dépourvu de symptômes psychotiques ou de psychoses. Les critères d'exclusion des sujets sont : (1) consommation d'alcool ou de drogues, (2) troubles psycho-organiques, (3) retard mental, (4) difficulté de compréhension de la langue française, (5) état de décompensation aiguë empêchant la réalisation de l'étude. Trois instruments sont utilisés comme supports d'analyses pour cette étude : (1) ELADEB, (2) l'Eye tracking et (3) le Gaze tracker. Le dispositif (2) d'Eye tracking se présente sous forme de lunettes particulières à porter par le sujet et qui permet de suivre les mouvements de l'oeil. L'une des caméras suit et enregistre les mouvements oculaires du sujet et permet de « voir en temps réel ce que voit le sujet et où il regarde » tandis que la seconde caméra scrute et analyse sa pupille. Les données sont ensuite répertoriées par le logiciel de mesures (3) « Gaze tracker », qui les analyse avec, à la fois une évaluation quantitative des points de fixation2 en se basant sur leurs nombres et leurs durées, ainsi qu'une mesure de la variation pupillaire fournie en pixels par le logiciel. Résultat(s) escompté(s) Il s'agit d'une étude exploratoire dans laquelle on espère retrouver les variations moyennes intra-sujets selon les hypothèses carte problème versus non problèmes. On peut s'attendre à trouver une retraduction des mesures de l'échelle ELADEB au travers de l'Eye tracking, ce qui concorderait avec les hypothèses énoncées et ajouterait encore d'avantage de validation à ELADEB au travers d'un outil pointu de mesure physiologique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Due to the power of genetics, the mouse has become a widely used animal model in vision research. However, its eyeball has an axial length of only about 2 mm. The present protocol describes how to easily dissect the small rodent eye post mortem. This allows collecting different tissues of the eye, i.e., cornea, lens, iris, retina, optic nerve, retinal pigment epithelium (RPE), and sclera. We further describe in detail how to process these eye samples in order to obtain high‐quality RNA for RNA expression profiling studies. Depending on the eye tissue to be analyzed, we present appropriate lysis buffers to prepare total protein lysates for immunoblot and immuno‐precipitation analyses. Fixation, inclusion, embedding, and cryosectioning of the globe for routine histological analyses (HE staining, DAPI staining, immunohistochemistry, in situ hybridization) is further presented. These basic protocols should allow novice investigators to obtain eye tissue samples rapidly for their experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether the relative afferent pupillary defect (RAPD) remains constant over time in normal subjects. METHODS: Seventeen normal subjects were tested with infrared pupillography and automated perimetry in four sessions over 3 years. The changes in RAPD and visual field asymmetry between testing sessions were compared. RESULTS: The range of RAPD was 0.0 to 0.3 log unit, and the difference in the mean deviation between the eyes on automated static perimetry was 0 to 3 dB. Eight subjects repeatedly had an RAPD in the same eye. There was no correlation between the RAPD and the visual field asymmetry at the same visit. Changes in the magnitude of the RAPD between any two sessions were typically small (median, 0.08 log unit; 25th percentile, 0.04 log unit; 75th percentile, 0.15 log unit). CONCLUSIONS: Some normal subjects may show a persistent but small RAPD in the absence of detectable pathologic disease. Therefore, an isolated RAPD in the range of 0.3 log unit that is not associated with any other significant historical or clinical finding should probably be considered benign.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to characterize local distribution and systemic absorption of the tumor necrosis factor (TNF)-alpha inhibitory single-chain antibody fragment (scFv) ESBA105 following topical administration to the eye in vivo. METHODS: Rabbits received ESBA105 as topical eye drops in two dosing regimens. First, pharmacokinetics after the topical route of administration was compared to the intravenous (i.v.) route by means of applying the identical cumulative daily dose of ESBA105. In a second study rabbits received five eye drops daily for six consecutive days in a lower frequency topical dosing regimen. Kinetics and biodistribution of ESBA105 in ocular tissues and fluids as well as in sera were determined in all animals. RESULTS: After topical administration to the eye, ESBA105 quickly reaches therapeutic concentrations in all ocular compartments. Systemic exposure after topical administration is 25,000-fold lower than exposure after i.v. injection of the identical cumulative daily dose. ESBA105 levels in vitreous humor and neuroretina are significantly higher on topical administration than after i.v. injection. Absolute and relative intraocular biodistribution of ESBA105 is different with topical and systemic delivery routes. Compared to its terminal half-life in circulation (7 hours), the vitreal half-life of ESBA105 is significantly enhanced (16-24 hours). CONCLUSIONS: On topical administration, ESBA105 is efficiently absorbed and distributed to all compartments of the eye, whereby systemic drug exposure is very low. Based on its unique intraocular biodistribution and pharmacokinetics and the absolute intraocular levels reached, topical ESBA105 appears highly attractive for treatment of various ophthalmological disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les résultats préliminaires de trois essais cliniques de thérapie génique d'une forme agressive de rétinite pigmentaire (l'amaurose congénitale de Leber) ont prouvé que le traitement des maladies dégénératives de la rétine par transfert de gène peut être sûr et efficace pour rétablir une fonction visuelle. Il faudra encore attendre les résultats à long terme de ces études pour que soit définitivement validée cette approche thérapeutique. Dans l'intervalle, il importe de se préparer à son introduction en ophtalmologie de façon à la rendre accessible à nos malades. Pratiquement cela revient à promouvoir: 1) le recrutement; 2) la caractérisation du phénotype et du génotype des sujets atteints et 3) la constitution d'un registre des rétinopathies héréditaires. Recently, preliminary results of three clinical gene therapy trials for early onset retinitis pigmentosa--Leber congenital amaurosis--suggested that treating this degenerative retinal disease by gene transfection can be safe and efficient to restore a visual function. The definitive validation of this therapeutic approach depends on the long-term results. The forthcoming availability of gene therapy in ophthalmology prompts the implementation: of 1) recruitment, 2) phenotyping and genotyping of affected patients, 3) and creation of a hereditary retinopathy registry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We aimed to determine whether human subjects' reliance on different sources of spatial information encoded in different frames of reference (i.e., egocentric versus allocentric) affects their performance, decision time and memory capacity in a short-term spatial memory task performed in the real world. Subjects were asked to play the Memory game (a.k.a. the Concentration game) without an opponent, in four different conditions that controlled for the subjects' reliance on egocentric and/or allocentric frames of reference for the elaboration of a spatial representation of the image locations enabling maximal efficiency. We report experimental data from young adult men and women, and describe a mathematical model to estimate human short-term spatial memory capacity. We found that short-term spatial memory capacity was greatest when an egocentric spatial frame of reference enabled subjects to encode and remember the image locations. However, when egocentric information was not reliable, short-term spatial memory capacity was greater and decision time shorter when an allocentric representation of the image locations with respect to distant objects in the surrounding environment was available, as compared to when only a spatial representation encoding the relationships between the individual images, independent of the surrounding environment, was available. Our findings thus further demonstrate that changes in viewpoint produced by the movement of images placed in front of a stationary subject is not equivalent to the movement of the subject around stationary images. We discuss possible limitations of classical neuropsychological and virtual reality experiments of spatial memory, which typically restrict the sensory information normally available to human subjects in the real world.