126 resultados para urinary sphincter, artificial

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Severe heart failure and cerebral stroke are broadly associated with the impairment of muscular function that conventional treatments struggle to restore. New technologies enable the construction of "smart" materials that could be of great help in treating diseases where the main problem is muscle weakness. These materials "behave" similarly to biological systems, because the material directly converts energy, for example electrical energy into movement. The extension and contraction occur silently like in natural muscles. The real challenge is to transfer this amazing technology into devices that restore or replace the mechanical function of failing muscle. Cardiac assist devices based on artificial muscle technology could envelope a weak heart and temporarily improve its systolic function, or, if placed on top of the atrium, restore the atrial kick in chronic atrial fibrillation. Artificial sphincters could be used to treat urinary incontinence after prostatectomy or faecal incontinence associated with stomas. Artificial muscles can restore the ability of patients with facial paralysis due to stroke or nerve injury to blink. Smart materials could be used to construct an artificial oesophagus including peristaltic movement and lower oesophageal sphincter function to replace the diseased oesophagus thereby avoiding the need for laparotomy to mobilise stomach or intestine. In conclusion, in the near future, smart devices will integrate with the human body to fill functional gaps due to organ failure, and so create a human chimera.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION AND HYPOTHESIS: This study aims to estimate fecal, urinary incontinence, and sexual function 6 years after an obstetrical anal sphincter tear. METHODS: Among 13,213 women who had a vaginal delivery of a cephalic singleton at term, 196 women sustained an anal sphincter tear. They were matched to 588 controls. Validated questionnaires grading fecal and urinary incontinence, and sexual dysfunction were completed by the participants. RESULTS: Severe fecal incontinence was more frequently reported by women who had sustained an anal sphincter tear compared to the controls. Women with an anal sphincter tear had no increased risk of urinary incontinence, but reported significantly more pain, difficulty with vaginal lubrication, and difficulty achieving orgasm compared to the controls. A fetal occiput posterior position during childbirth was an independent risk factor for both severe urinary incontinence and severe sexual dysfunction. CONCLUSIONS: Fecal incontinence is strongly associated with an anal sphincter tear. A fetal occiput posterior position represents a risk factor for urinary incontinence and sexual dysfunction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To investigate by electromyography (EMG), the presence of complex repetitive discharges (CRDs) and decelerating bursts (DBs) in the striated external urethral sphincter during the menstrual cycle in female volunteers with no urinary symptoms and complete bladder emptying. SUBJECTS AND METHODS: Healthy female volunteers aged 20-40 years, with regular menstrual cycles and no urinary symptoms were recruited. Volunteers completed a menstruation chart, urinary symptom questionnaires, pregnancy test, urine dipstick, urinary free flow and post-void ultrasound bladder scan. Exclusion criteria included current pregnancy, use of hormonal medication or contraception, body mass index of >35 kg/m(2) , incomplete voiding and a history of pelvic surgery. Eligible participants underwent an external urethral sphincter EMG, using a needle electrode in the early follicular phase and the mid-luteal phase of their menstrual cycles. Serum oestradiol and progesterone were measured at each EMG test. RESULTS: In all, 119 women enquired about the research and following screening, 18 were eligible to enter the study phase. Complete results were obtained in 15 women. In all, 30 EMG tests were undertaken in the 15 asymptomatic women. Sphincter EMG was positive for CRDs and DBs at one or both phases of the menstrual cycle in eight (53%) of the women. Three had CRDs and DBs in both early follicular and mid-luteal phases. Five had normal EMG activity in the early follicular phase and CRDs and DBs in the mid-luteal phase. No woman had abnormal EMG activity in the early follicular phase and normal activity in the luteal phase. There was no relationship between EMG activity and age, parity or serum levels of oestradiol and progesterone. CONCLUSIONS: CRDs and DB activity in the external striated urethral sphincter is present in a high proportion of asymptomatic young women. This abnormal EMG activity has been shown for the first time to change during the menstrual cycle in individual women. CRDs and DBs are more commonly found in the luteal phase of the menstrual cycle. The importance of CRDs and DBs in the aetiology of urinary retention in young women remains uncertain. The distribution and or quantity of abnormal EMG activity in the external urethral sphincter may be important. In a woman with urinary retention the finding of CRDs and DBs by needle EMG does not automatically establish Fowler's syndrome as the explanation for the bladder dysfunction. Urethral pressure profilometry may be helpful in establishing a diagnosis. Opiate use and psychological stress should be considered in young women with urinary retention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Folpet is one of the most widely employed fungicides in agriculture. It is typically used in the culture of vegetables, fruits and ornamental plants. Once absorbed in the human body, it has been found to be very reactive, especially in acid conditions. According to various in vitro and in vivo experiments in animals, Folpet is first fractioned at the N-S link when in contact with aqueous solutions and thiol groups. From this non-enzymatic process a phthalimide (PI) molecule is formed, which may be used as a biomarker of exposure, along with the short-lived thiophosgene. We have built a human toxicokinetic model to account for the biotransformation of Folpet into PI and its subsequent excretion while accounting for other non-monitored metabolites. The mathematical parameters of the model were determined accordingly from best-fits to the time courses of PI in blood and urine of five volunteers administered orally 1 mg/kg and dermally 10 mg/kg of Folpet. In both cases, the mean elimination half-life of PI from the body (either through faeces, urine or metabolism) was found to be 31.6 h. The average final fractions of administered dose recovered in urine as PI were 0.025% and 0.002%, for oral and dermal administration, respectively after 96 h. According to the model, when orally administered, PI rapidly hydrolyzes to phthalamic and phthalic acids such that only 0.04% of the PI found in the gastrointestinal tract is absorbed into the blood stream. Likewise, after dermal application, model predicts that only 7.4% of the applied Folpet dose crosses the epidermis. In the model, the PI initial metabolite of Folpet is formed in the dermis and further metabolized prior to reaching systemic circulation, such that only 0.125% of PI formed at the site-of-entry reaches systemic blood. Our mathematical model is in accordance with both measures of blood (R2=0.57 for dermal and R2=0.66 for oral) and urine (R2 =0.98 for dermal and R2=0.99 for oral).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Low 24-hour urine volume (24 UV) may be a significant risk factor for decline in kidney function. We therefore aimed to study associated markers and possible determinants of 24 UV in a sample of the Swiss population. METHODS: The cross-sectional Swiss Salt Study included a population-based sample of 1535 (746 men and 789 women) individuals from three linguistic regions of Switzerland. Data from 1300 subjects were available for the present analysis. 24 UV was measured using 24-hour urine collection. Determinants of 24 UV were identified using multivariable linear regression models. RESULTS: In bivariate analysis, 24 UV was higher in women compared to men (2000 ml/24 h [interquartile range (IQR): 1354, 2562] versus 1780 ml/24 h [IQR: 1244, 2360], p = 0.002). In multivariable regression analyses, independent associated markers of 24 UV were female sex (β = 280, 95% confidence interval [CI]: 174, 386, p < 0.0001), fluid intake (β = 604, 95% CI: 539, 670, p < 0.0001), sodium excretion (β = 4.2, 95% CI: 3.4, 4.9, p < 0.0001) age (β = 6.6, CI: 3.4, 9.7, p < .0001), creatinine clearance (β = 2.4, CI: 0.2, 4.6, p = 0.04), living in the German-speaking part of Switzerland (β = 124, CI: 29, 219, p = 0.01), alcohol consumption (β = 41, CI: 9, 73, p = 0.01 for increasing categories of alcohol consumption), body mass index (β = -32, CI: -45, -18, p < 0.0001), current smoking (β = -146, CI: -265, -26, p = 0.02), and consumption of meat and cold cut (β = -56, CI: -108, -5, p = 0.03). CONCLUSION: In this large population-based, cross-sectional study, we found several strong and independent correlates for 24 UV. These findings may be important to improve our understanding in the development of chronic kidney disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the study was to determine reference percentiles for the urinary (U) oxalate (Ox) and urate (Ura) to creatinine (Cr) concentration ratios in the second morning urine of healthy infants, children, and adolescents. The urinary oxalate and urate to creatinine ratios were determined in the spontaneously voided second morning urine sample. To test reproducibility, two urine samples were analyzed on 2 consecutive weeks in 63% of the subjects. Three hundred eighty-four healthy children (181 girls, 203 boys), aged 1 month to 17 years, from nurseries, kindergartens, and schools of Lausanne, Switzerland, were studied. The 5th and 95th percentiles were determined from the total number of urine samples (627) after confirmation that there was no order effect between repeated measurements and there were no significant sex differences. A nonlinear regression analysis in terms of age was used to smooth the calculated percentiles. In this manner, curves were obtained from which the reference values can be read at any given age. The 95th percentiles decreased with age: for UOx/Cr from 0.175 mg/mg (0.22 mol/mol) at 1 to 6 months to 0.048 mg/mg (0.06 mol/mol) from 7 years and beyond; and UUra/Cr from 2.378 mg/mg (1.6 mol/mol) at 1 to 6 months to 0.594 mg/mg (0.4 mol/mol) in adolescence. We provide 5th and 95th percentile curves for the UOx/Cr and UUra/Cr ratios determined from the second morning urine samples in a large cohort of healthy infants, children, and adolescents. Values were determined by standard analytical chemical techniques and were analyzed by powerful statistical methods. The calculated 95th percentile for the UOx/Cr values fell rather rapidly and reached normal adult values by the age of 7 years, whereas for UUra/Cr, the 95th percentile decreased slowly and stabilized in adolescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We would like to comment this study recently published in JFS. It is a short technical note proposing an artificial aging technique for the dating of ballpoint pen inks. This is a very difficult and controversial topic, and we are worried about the nature of this paper. The authors propose several ideas to differentiate fast aging and slow aging inks, but their experimental data is not validly represented and/or discussed. The data is insufficient to draw any conclusions about any potential of the method for ink dating purposes. This lack of information on the subject must be filled before proposing such methods for practical caseworks. These are preliminary and unconvincing results from development research performed in a laboratory on controlled samples without due warnings about potential shortcomings. They cannot be used or even compared to results obtained in real situations on uncontrolled specimens of limited size, unknown composition and undefined storage conditions. This can leave an undeserved feeling that these methods are ready for implementation when the task of ensuring their scientific validity is still far away.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates in vitro growth of human urinary tract smooth muscle cells under static conditions and mechanical stimulation. The cells were cultured on collagen type I- and laminin-coated silicon membranes. Using a Flexcell device for mechanical stimulation, a cyclic strain of 0-20% was applied in a strain-stress-time model (stretch, 104 min relaxation, 15 s), imitating physiological bladder filling and voiding. Cell proliferation and alpha-actin, calponin, and caldesmon phenotype marker expression were analyzed. Nonstretched cells showed significant better growth on laminin during the first 8 days, thereafter becoming comparable to cells grown on collagen type I. Cyclic strain significantly reduced cell growth on both surfaces; however, better growth was observed on laminin. Neither the type of surface nor mechanical stimulation influenced the expression pattern of phenotype markers; alpha-actin was predominantly expressed. Coating with the extracellular matrix protein laminin improved in vitro growth of human urinary tract smooth muscle cells.