2 resultados para test-day milk yield
em Université de Lausanne, Switzerland
Resumo:
The "Five-Day Plan to Stop Smoking" (FDP) is an educational group technique for smoking cessation. We studied a cohort of 123 smokers (55 men, 68 women, mean age 42 years) who participated in 11 successive FDP sessions held in Switzerland between 1995 and 1998 and who were followed up for at least 12 months by telephone or direct interview. Overall, 102 of the 123 subjects (83%) had stopped smoking by the end of the FDP, and self-declared smoking cessation rate was 25% after one year. The following factors potentially associated with outcome were studied: age, sex, smoking habit duration, cigarettes per day, Fagerström Test for Nicotine Dependence (FTND), group size, and medical presence among the group leaders. Smoking habit duration was the only variable which showed a statistically significant association with success: the rate of smoking cessation was higher among patients who had smoked for less than 20 years (34.7% vs. 18.9%, p = 0.049). Stress was the most common cause of relapse. The FDP appears to be an effective smoking cessation therapy. Propositions are made in order to improve the success rate of future sessions.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.