123 resultados para stability, cytotoxics, monitoring, HPLC, antibody
em Université de Lausanne, Switzerland
Resumo:
A simple and sensitive LC-MS method was developed and validated for the simultaneous quantification of aripiprazole (ARI), atomoxetine (ATO), duloxetine (DUL), clozapine (CLO), olanzapine (OLA), sertindole (STN), venlafaxine (VEN) and their active metabolites dehydroaripiprazole (DARI), norclozapine (NCLO), dehydrosertindole (DSTN) and O-desmethylvenlafaxine (OVEN) in human plasma. The above mentioned compounds and the internal standard (remoxipride) were extracted from 0.5 mL plasma by solid-phase extraction (mix mode support). The analytical separation was carried out on a reverse phase liquid chromatography at basic pH (pH 8.1) in gradient mode. All analytes were monitored by MS detection in the single ion monitoring mode and the method was validated covering the corresponding therapeutic range: 2-200 ng/mL for DUL, OLA, and STN, 4-200 ng/mL for DSTN, 5-1000 ng/mL for ARI, DARI and finally 2-1000 ng/mL for ATO, CLO, NCLO, VEN, OVEN. For all investigated compounds, good performance in terms of recoveries, selectivity, stability, repeatability, intermediate precision, trueness and accuracy, was obtained. Real patient plasma samples were then successfully analysed.
Resumo:
Most anticancer drugs are characterised by a steep dose-response relationship and narrow therapeutic window. Inter-individual pharmacokinetic (PK) variability is often substantial. The most relevant PK parameter for cytotoxic drugs is the area under the plasma concentration versus time curve (AUC). Thus it is somewhat surprising that therapeutic drug monitoring (TDM) is still uncommon for the majority of agents. Goals of the review were to assess the rationale for more widely used TDM of cytotoxics in oncology. There are several reasons why TDM has never been fully implemented into daily oncology practice. These include difficulties in establishing appropriate concentration target ranges, common use of combination chemotherapies for many tumour types, analytical challenges with prodrugs, intracellular compounds, the paucity of published data from pharmacological trials and 'Day1=Day21' administration schedules. There are some specific situations for which these limitations are overcome, including high dose methotrexate, 5-fluorouracil infusion, mitotane and some high dose chemotherapy regimens. TDM in paediatric oncology represents an important challenge. Established TDM approaches includes the widely used anticancer agents carboplatin, busulfan and methotrexate, with 13-cis-retinoic acid also recently of interest. Considerable effort should be made to better define concentration-effect relationships and to utilise tools such as population PK/PD models and comparative randomised trials of classic dosing versus pharmacokinetically guided adaptive dosing. There is an important heterogeneity among clinical practices and a strong need to promote TDM guidelines among the oncological community.
Resumo:
Aims: A rapid and simple HPLC-MS method was developed for the simultaneousdetermination of antidementia drugs, including donepezil, galantamine, rivastigmineand its major metabolite NAP 226 - 90, and memantine, for TherapeuticDrug Monitoring (TDM). In the elderly population treated with antidementiadrugs, the presence of several comorbidities, drug interactions resulting frompolypharmacy, and variations in drug metabolism and elimination, are possiblefactors leading to the observed high interindividual variability in plasma levels.Although evidence for the benefit of TDM for antidementia drugs still remains tobe demonstrated, an individually adapted dosage through TDM might contributeto minimize the risk of adverse reactions and to increase the probability of efficienttherapeutic response. Methods: A solid-phase extraction procedure with amixed-mode cation exchange sorbent was used to isolate the drugs from 0.5 mL ofplasma. The compounds were analyzed on a reverse-phase column with a gradientelution consisting of an ammonium acetate buffer at pH 9.3 and acetonitrile anddetected by mass spectrometry in the single ion monitoring mode. Isotope-labeledinternal standards were used for quantification where possible. The validatedmethod was used to measure the plasma levels of antidementia drugs in 300patients treated with these drugs. Results: The method was validated accordingto international standards of validation, including the assessment of the trueness(-8 - 11 %), the imprecision (repeatability: 1-5%, intermediate imprecision:2 - 9 %), selectivity and matrix effects variability (less than 6 %). Furthermore,short and long-term stability of the analytes in plasma was ascertained. Themethod proved to be robust in the calibrated ranges of 1 - 300 ng/mL for rivastigmineand memantine and 2 - 300 mg/mL for donepezil, galantamine and NAP226 - 90. We recently published a full description of the method (1). We found ahigh interindividual variability in plasma levels of these drugs in a study populationof 300 patients. The plasma level measurements, with some preliminaryclinical and pharmacogenetic results, will be presented. Conclusion: A simpleLC-MS method was developed for plasma level determination of antidementiadrugs which was successfully used in a clinical study with 300 patients.
Resumo:
An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
In 1995 the working group "Drug Monitoring" of the Swiss Society of Clinical Chemistry (SSCC) has already published a printed version of drug monographs, which are now newly compiled and presented in a standardised manner. The aim of these monographs is to give an overview on the most important informations that are necessary in order to request a drug analysis or is helpful to interpret the results. Therefore, the targeted audience are laboratory health professionals or the receivers of the reports. There is information provided on the indication for therapeutic drug monitoring, protein binding, metabolic pathways and enzymes involved, elimination half life time and elimination routes as well as information on therapeutic or toxic concentrations. Because preanalytical considerations are of particular importance for therapeutic drug monitoring, there is also information given at which time the determination of the drug concentration is reasonable and when steady-state concentrations are reached after changing the dose. Furthermore, the stability of the drug and its metabolite(s), respectively, after blood sampling is described. For readers with a specific interest, references to important publications are given. The number of the monographs will be continuously enlarged. The updated files are presented on the homepage of the SSCC (www.sscc.ch).
Resumo:
The preparation of a novel radioiodination reagent, the (aminooxy)acetyl derivative of (p-[125]-iodophenyl)ethylamine, is described. Conventional radioiodination of proteins involves the formation of iodotyrosine residues, but for in vivo applications such as thyroid or stomach immunoscintigraphy, the susceptibility of these residues to tissue dehalogenases constitutes a serious disadvantage. Using our new compound, which has a particularly nonreactive aromatic ring, we confirm and extend studies published by other workers indicating the much greater in vivo stability of iodophenyl compounds compared to the more conventional iodophenolic ones. In addition, the aminooxy group of our reagent gives a stable and specific linkage to aldehyde groups formed by periodate oxidation on the sugar moiety of antibody molecules. In vitro, favorable binding activity and high stability was obtained with a (([125I]iodoaryl)amino)oxy labeled monoclonal antibody directed against carcinoembryonic antigen. In vivo, using paired labeling experiments in nude mice bearing colon carcinoma xenografts, the (([125I]iodoaryl)amino)oxy-MAb (MAb = monoclonal antibody) was compared with the same MAb 131I-labeled by conventional chloramine-T method. Tumor 125I concentration of (arylamino)oxy MAb (measured as percent injected dose per gram) was significantly higher as compared to values obtained with a conventionally labeled 131I antibody. Additionally, thyroid uptake, an indicator of iodine release from the antibody, was up to 25 times lower after injection of 125I-MAb obtained by the new method as compared to the conventionally iodinated 131I-MAb.
Resumo:
BACKGROUND: Persisting metallic intraocular foreign bodies (IOFB) with a ferrous content have been associated with ocular siderosis and retinal degeneration. We describe two patients in whom a metallic IOFB containing iron was left embedded for many years in the choroid and sclera after having penetrated through the vitreous and the retina. HISTORY AND SIGNS: Two male patients, aged 41 and 48 years, presented with a metallic IOFB sustained during a work accident involving metal tools. THERAPY AND OUTCOME: For the first patient it was deemed unwise to operate, as the IOFB was also lodged very deeply in the choroid and sclera in the inferior temporal quadrant. The second patient underwent pars plana vitrectomy, but the IOFB could not be removed surgically as it was too deeply embedded in the sclera and choroid. After a period of 6 years (Case 1) and 4 years (Case 2) of follow-up, visual acuity remained at 1.0 and the IOFB was encased in a fibrotic capsule in both cases. Full-field and multifocal electroretinograms showed an inter-ocular asymmetry at baseline, which remained stable during the follow-up. CONCLUSIONS: Ocular siderosis may not develop in patients with a deeply embedded metallic IOFB. Regular monitoring of both visual function and the electroretinogram is mandatory when the IOFB is left inside the eye.
Resumo:
The study of natural T cell responses against pathogens or tumors, as well as the assessment of new immunotherapy strategies aimed at boosting these responses, requires increasingly precise ex vivo analysis of blood samples. For practical reasons, studies are often performed using purified PBMC samples, usually cryopreserved. Here, we report on FACS analyses of peripheral blood T cells, performed by direct antibody staining of non-purified total blood. For comparison, fresh PBMC, purified by Ficoll, were analysed. Our results show that the latter method can induce a bias in subpopulation distribution, in particular of CD8+ T cells, and sometimes lead to inaccurate measurement of antigen specific CD8+ T cell responses. Direct analysis of total blood can be applied to longitudinal immuno-monitoring of T cell-based therapy. While the need to purify and cryopreserve PBMC for subsequent studies is obvious, the use of whole blood has the advantage of providing unbiased results and only small amounts of blood are used.
Resumo:
In addition to the monographs which were published last year by the working group "Drug Monitoring" of the Swiss Society of Clinical Chemistry (SSCC) [1], new monographs have been written. The aim of these monographs is to give an overview of the most important information necessary for ordering a drug analysis or interpreting the results. Therefore, the targeted readers comprise laboratory health professionals and all receivers of laboratory reports. There is information provided on the indication for therapeutic drug monitoring, protein binding, metabolic pathways and enzymes involved, elimination half-life and elimination routes, and on therapeutic or toxic concentrations. Preanalytical considerations are of particular importance for therapeutic drug monitoring. Therefore, information is provided regarding a reasonable timing for the determination of drug concentrations as well as steady-state concentrations after changing the dose. Furthermore, the stability of the drug and its metabolite(s) after blood sampling is described. For readers with a specific interest in drug analysis, references to important publications are given. The number of monographs will be continuously enlarged. The updated files are presented on the homepage of the SSCC (www.sscc.ch).
Resumo:
The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.
Resumo:
A liquid chromatography method coupled to mass spectrometry was developed for the quantification of bupropion, its metabolite hydroxy-bupropion, moclobemide, reboxetine and trazodone in human plasma. The validation of the analytical procedure was assessed according to Société Française des Sciences et Techniques Pharmaceutiques and the latest Food and Drug Administration guidelines. The sample preparation was performed with 0.5mL of plasma extracted on a cation-exchange solid phase 96-well plate. The separation was achieved in 14min on a C18 XBridge column (2.1mm×100mm, 3.5μm) using a 50mM ammonium acetate pH 9/acetonitrile mobile phase in gradient mode. The compounds of interest were analysed in the single ion monitoring mode on a single quadrupole mass spectrometer working in positive electrospray ionisation mode. Two ions were selected per molecule to increase the number of identification points and to avoid as much as possible any false positives. Since selectivity is always a critical point for routine therapeutic drug monitoring, more than sixty common comedications for the psychiatric population were tested. For each analyte, the analytical procedure was validated to cover the common range of concentrations measured in plasma samples: 1-400ng/mL for reboxetine and bupropion, 2-2000ng/mL for hydroxy-bupropion, moclobemide, and trazodone. For all investigated compounds, reliable performance in terms of accuracy, precision, trueness, recovery, selectivity and stability was obtained. One year after its implementation in a routine process, this method demonstrated a high robustness with accurate values over the wide concentration range commonly observed among a psychiatric population.
Resumo:
Injectable drugs are high-risk products and their reconstitution in hospital wards is a potential source of errors. Thus, in order to secure the reconstitution process and thereby improve safety, the pharmacy department of Lausanne University Hospital is focusing on developing ready-to-use forms (CIVAS). These preparations are compounded in controlled clean rooms and are analyzed prior to release. In the intensive care unit, amiodarone 12.5 mg/mL in glucose 5% is one of the high-risk preparations, which has led the pharmacy to develop a ready-to-use solution. To this end, a one-year stability study was initiated, and the preliminary results (after six months) are illustrated here. A stability-indicating HPLC method was developed and validated for monitoring the concentration of amiodarone. Batches were stored at 5 °C and 30 °C, which were analyzed immediately after preparation, after one, two, four and six months of storage. The pH and osmolality values were monitored at the respective time intervals. It was observed that after six months, all the results were within specifications. However, the pH values started to decrease after two months when amiodarone was stored at 30 °C. After six months, a degradation peak appeared on the chromatogram of these solutions, which suggested that amiodarone is more stable at 5 °C. The preliminary results obtained in this study indicated that injectable amiodarone solutions are stable for six months under refrigerated storage conditions. The study is ongoing.
Resumo:
A bispecific MAb was derived from the fusion of a hybridoma producing MAb CD3 with a hybridoma producing MAb L-DI (which is directed against a 41-kDa glycoprotein expressed in most gastro-intestinal and pancreatic carcinomas). Bispecific antibody molecules were isolated from parental antibody molecules by the use of hydroxylapatite-HPLC and shown to target human cytolytic T lymphocytes, irrespective of their original specificity, to specifically lyse human colon carcinoma cells. Localization studies in vivo using nude mice bearing human colon carcinoma xenografts showed significant accumulation of the HPLC-purified 125I-labelled bispecific antibodies into the tumor compared to 131I-labelled control CD3 antibody.
Resumo:
Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.