56 resultados para solution contamination

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

As part of a project to use the long-lived (T(1/2)=1200a) (166m)Ho as reference source in its reference ionisation chamber, IRA standardised a commercially acquired solution of this nuclide using the 4pibeta-gamma coincidence and 4pigamma (NaI) methods. The (166m)Ho solution supplied by Isotope Product Laboratories was measured to have about 5% Europium impurities (3% (154)Eu, 0.94% (152)Eu and 0.9% (155)Eu). Holmium had therefore to be separated from europium, and this was carried out by means of ion-exchange chromatography. The holmium fractions were collected without europium contamination: 162h long HPGe gamma measurements indicated no europium impurity (detection limits of 0.01% for (152)Eu and (154)Eu, and 0.03% for (155)Eu). The primary measurement of the purified (166m)Ho solution with the 4pi (PC) beta-gamma coincidence technique was carried out at three gamma energy settings: a window around the 184.4keV peak and gamma thresholds at 121.8 and 637.3keV. The results show very good self-consistency, and the activity concentration of the solution was evaluated to be 45.640+/-0.098kBq/g (0.21% with k=1). The activity concentration of this solution was also measured by integral counting with a well-type 5''x5'' NaI(Tl) detector and efficiencies computed by Monte Carlo simulations using the GEANT code. These measurements were mutually consistent, while the resulting weighted average of the 4pi NaI(Tl) method was found to agree within 0.15% with the result of the 4pibeta-gamma coincidence technique. An ampoule of this solution and the measured value of the concentration were submitted to the BIPM as a contribution to the Système International de Référence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A burn patient was infected with Acinetobacter baumannii on transfer to the hospital after a terrorist attack. Two patients experienced cross-infection. Environmental swab samples were negative for A. baumannii. Six months later, the bacteria reemerged in 6 patients. Environmental swab samples obtained at this time were inoculated into a minimal mineral broth, and culture results showed widespread contamination. No case of infection occurred after closure of the unit for disinfection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to perform a thorough comparison of quantitative susceptibility mapping (QSM) techniques and their dependence on the assumptions made. The compared methodologies were: two iterative single orientation methodologies minimizing the l2, l1TV norm of the prior knowledge of the edges of the object, one over-determined multiple orientation method (COSMOS) and anewly proposed modulated closed-form solution (MCF). The performance of these methods was compared using a numerical phantom and in-vivo high resolution (0.65mm isotropic) brain data acquired at 7T using a new coil combination method. For all QSM methods, the relevant regularization and prior-knowledge parameters were systematically changed in order to evaluate the optimal reconstruction in the presence and absence of a ground truth. Additionally, the QSM contrast was compared to conventional gradient recalled echo (GRE) magnitude and R2* maps obtained from the same dataset. The QSM reconstruction results of the single orientation methods show comparable performance. The MCF method has the highest correlation (corrMCF=0.95, r(2)MCF =0.97) with the state of the art method (COSMOS) with additional advantage of extreme fast computation time. The l-curve method gave the visually most satisfactory balance between reduction of streaking artifacts and over-regularization with the latter being overemphasized when the using the COSMOS susceptibility maps as ground-truth. R2* and susceptibility maps, when calculated from the same datasets, although based on distinct features of the data, have a comparable ability to distinguish deep gray matter structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://resfranco.cochrane.org/sites/resfranco.cochrane.org/files/uploads/Arrettabac2009.pdf

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanically ventilated patients in hospitals are subjected to an increased risk of acquiring nosocomial pneumonia that sometimes has a lethal outcome. One way to minimize the risk could be to make the surfaces on endotracheal tubes antibacterial. In this study, bacterial growth was inhibited or completely prevented by silver ions wet chemically and deposited onto the tube surface. Through the wet chemical treatment developed here, a surface precipitate was formed containing silver chloride and a silver stearate salt. The identity and morphology of the surface precipitate was studied using x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, and x-ray powder diffraction. Leaching of silver ions into solution was examined, and bacterial growth on the treated surfaces was assayed using Pseudomonas aeruginosa wild type (PAO1) bacteria. Furthermore, the minimum inhibitory concentration of silver ions was determined in liquid- and solid-rich growth medium as 23 and 18 microM, respectively, for P. aeruginosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'exposition aux bactéries résistantes aux antibiotiques, en particulier à Staphylococcus aureus résistant à la méthicilline (SARM (1)) sur le lieu de travail, a été montrée comme étant un facteur de risque pour la santé des opérateurs, la fréquence des contacts avec cette bactérie augmentant la probabilité d'en devenir porteur. En plus du fait que les SARM augmentent d'un facteur 4 le risque d'infection chez le porteur, le choix du traitement antibiotique en cas d'infection est fortement limité. C'est pourquoi il est important d'identifier les environnements de travail et les conditions qui favorisent la transmission de cette bactérie de l'animal à l'Homme. La résistance à la méthicilline est conférée au S. aureus par un élément génétique mobile, appelé « staphylococcal cassette chromosome » mec (SCCmec), qui contient le gène de résistance à la méthicilline, mecA. SCCmec a cinq formes (I, II, III, IV and V) qui ont été acquises et intégrées dans le génome de S. aureus lors d'événements indépendants de transfert horizontal. Certaines de ces lignées spécifiquement associées au bétail traité aux antibiotiques (tel que le complexe clonal 398, CC398 (2)), peuvent également coloniser le nez humain. Ainsi, la colonisation nasale ou contamination a été constatée chez 23 à 86 % des agriculteurs et vétérinaires ayant un contact direct avec des porcs, ainsi que chez un à cinq pour cent des personnes ayant une exposition indirecte (par exemple les membres de la famille d'agriculteurs, les visiteurs de la ferme). La pathogénicité du SARM CC398 pour l'Homme a été documentée dans une série de rapports décrivant des cas d'endocardite, d'otomastoïdite et de pneumonie. En outre, le SARM CC398 a été introduit dans des structures de santé (hôpitaux, cliniques, etc.) situées principalement dans les zones d'élevage à forte densité. Si les porcs sont des vecteurs bien connus de transmission de CC398 à l'Homme, d'autres animaux peuvent l'être également, tels que les dindes en Allemagne, comme illustré par le premier article cité dans cette note. Par ailleurs, la propagation de ces souches résistantes aux antibiotiques est inquiétante. Le deuxième article de cette note révèle l'apparition de souches de CC398 dans le lait de vache au Royaume-Uni pays où, jusqu'alors, la surveillance n'en avait pas détecté.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multiscale finite volume (MsFV) method has been developed to efficiently solve large heterogeneous problems (elliptic or parabolic); it is usually employed for pressure equations and delivers conservative flux fields to be used in transport problems. The method essentially relies on the hypothesis that the (fine-scale) problem can be reasonably described by a set of local solutions coupled by a conservative global (coarse-scale) problem. In most cases, the boundary conditions assigned for the local problems are satisfactory and the approximate conservative fluxes provided by the method are accurate. In numerically challenging cases, however, a more accurate localization is required to obtain a good approximation of the fine-scale solution. In this paper we develop a procedure to iteratively improve the boundary conditions of the local problems. The algorithm relies on the data structure of the MsFV method and employs a Krylov-subspace projection method to obtain an unconditionally stable scheme and accelerate convergence. Two variants are considered: in the first, only the MsFV operator is used; in the second, the MsFV operator is combined in a two-step method with an operator derived from the problem solved to construct the conservative flux field. The resulting iterative MsFV algorithms allow arbitrary reduction of the solution error without compromising the construction of a conservative flux field, which is guaranteed at any iteration. Since it converges to the exact solution, the method can be regarded as a linear solver. In this context, the schemes proposed here can be viewed as preconditioned versions of the Generalized Minimal Residual method (GMRES), with a very peculiar characteristic that the residual on the coarse grid is zero at any iteration (thus conservative fluxes can be obtained).