119 resultados para solid sampling technique
em Université de Lausanne, Switzerland
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 microm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (> 200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m(3))
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).
Resumo:
Owl pellets contain a good skeletal record of the small mammals consumed, and correspond to the undigested portions of prey which are regurgitated. These pellets are easy to find at the roosting site of owls. As it has been demonstrated that amplifiable DNA can be isolated from ancient bone remains, the possibility of using owl pellets as a source of DNA for small mammal genetics studies via the polymerase chain reaction has been investigated. The main uncertainties when isolating DNA from such a material are firstly the possibility that the extracted DNA would be too degraded during the digestion in the stomach of the owl, and secondly that extensive cross-contaminations could occur among the different prey consumed. The results obtained clearly demonstrate that cross-contamination does not occur, and that mitochondrial and nuclear DNA can be amplified using skulls of small mammals found in owl pellets as a source of DNA. The relative efficiency of two methods of DNA extraction is estimated and discussed. Thus, owl pellets represent a non-invasive sampling technique which provides a valuable source of DNA for studying population genetics of small mammals.
Resumo:
Introduction. If we are to promote more patient-centred approaches in care delivery, we have to better characterize the situations in which being patient-centred is difficult to achieve. Data from professionals in health and social care are important because they are the people charged with operationalizing patient-centred care (PCC) in their daily practice. However, empirical accounts from frontline care providers are still lacking, and it is important to gather experiences not only from doctors but also from the other care providers. Indeed, experiences from different professions can help inform our understanding of patient care, which is expected to be both patient-centred and collaborative. Methods. This study was based on the following research question: What factors make the provision of PCC difficult to achieve? Sample and setting. A purposeful sampling technique was used, allowing for a series of choices about the participants and their professional affiliation. Because patient-centredness is the focus, 3 professions appeared to be of special interest: general internists, nurses and social workers. The study was undertaken in the General Internal Medicine Division of a teaching hospital located in a North American context. Data Collection. To answer the research question, a methodological approach based on a theory called phenomenology was chosen. Accordingly, semi-structured interviews were used since they generate understanding of the meanings different individuals have of their lived world. Interviews with 8 physicians, 10 nurses and 10 social workers were eventually conducted. Data analysis. An inductive thematic analysis was employed to make sense of the interview data. Results. The thematic analysis allowed identifying various types of challenges to PCC. Although most of the challenges were perceived by all three groups of professionals, they were perceived to a different degree across the professions, which likely reflected the scope of practice of each profession. The challenges and their distribution across the professions are illustrated in Table 1. Examples of challenges are provided in Table 2. Discussion. There is a tension between what is supposed to be done - what stands in the philosophy of patient -centredness - and what is currently done - the real life with all the challenges to PCC. According to some participants' accounts, PCC clearly risks becoming a mere illusion for health care professionals on which too great pressures are imposed.
Resumo:
An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.
Resumo:
The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.
Resumo:
BACKGROUND: Mediastinal lymph-node dissection was compared to systematic mediastinal lymph-node sampling in patients undergoing complete resection for non-small cell lung cancer with respect to morbidity, duration of chest tube drainage and hospitalization, survival, disease-free survival, and site of recurrence. METHODS: A consecutive series of one hundred patients with non-small-cell lung cancer, clinical stage T1-3 N0-1 after standardized staging, was divided into two groups of 50 patients each, according to the technique of intraoperative mediastinal lymph-node assessment (dissection versus sampling). Mediastinal lymph-node dissection consisted of removal of all lymphatic tissues within defined anatomic landmarks of stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side according to the classification of the American Thoracic Society. Systematic mediastinal lymph-node sampling consisted of harvesting of one or more representative lymph nodes from stations 2-4 and 7-9 on the right side, and stations 4-9 on the left side. RESULTS: All patients had complete resection. A mean follow-up time of 89 months was achieved in 92 patients. The two groups of patients were comparable with respect to age, gender, performance status, tumor stage, histology, extent of lung resection, and follow-up time. No significant difference was found between both groups regarding the duration of chest tube drainage, hospitalization, and morbidity. However, dissection required a longer operation time than sampling (179 +/- 38 min versus 149 +/- 37 min, p < 0.001). There was no significant difference in overall survival between the two groups; however, patients with stage I disease had a significantly longer disease-free survival after dissection than after sampling (60.2 +/- 7 versus 44.8 +/- 8 months, p < 0.03). Local recurrence was significantly higher after sampling than after dissection in patients with stage I tumor (12.5% versus 45%, p = 0.02) and in patients with nodal tumor negative mediastinum (N0/N1 disease) (46% versus 13%, p = 0.004). CONCLUSION: Our results suggest that mediastinal lymph-node dissection may provide a longer disease-free survival in stage I non-small cell lung cancer and, most importantly, a better local tumor control than mediastinal lymph-node sampling after complete resection for N0/N1 disease without leading to increased morbidity.
Resumo:
Introduction : Les tumeurs solides pseudo-papillaires du pancréas (SPT) sont des tumeurs rares, d'étiopathogénie encore incertaine.Le but de notre travail était de décrire les caractéristiques radiologiques des SPT dans le groupe d'âge pédiatrique et d'étudier leur corrélation avec les études anatomopathologiques en vue d'établir un diagnostic.Patients et Méthodes : Nous avons étudié rétrospectivement trois malades pédiatriques pour lesquelles le diagnostic de tumeur solide pseudo-papillaire du pancréas a été porté à l'examen d'une pièce opératoire. Ce groupe comprenait 3 jeunes filles et femmes (âge médian: 13 ans).Résultats : La tumeur a été découverte pendant le bilan de symptômes digestifs non spécifiques. Les examens biologiques n'étaient pas informatifs. Des investigations radiologiques complètes ont été réalisées y compris les ultrasons (US), la tomodensitométrie (CT) et l'imagerie par résonance magnétique (IRM).Celles-ci ont montré de volumineuses lésions nodulaires, peu vascularisées, de compositions habituellement hétérogènes, avec des composantes kystiques et hémorragiques identifiées dans les 3 cas. Un traitement chirurgical a été pratiqué chez toute les patientes. L'étude de la pièce opératoire a montré une tumeur encapsulée dans les 3 cas. Aucune métastase n'a été mise en évidence.Conclusion : Les SPT doivent être considérées dans le diagnostic différentiel des masses pancréatiques pédiatriques, en particulier chez les adolescentes. Certaines caractéristiques radiologiques comme des masses volumineuses bien circonscrites, des lésions hétérogènes avec des zones kystiques et hémorragiques, de plus entourées d'une pseudocapsule fibreuse réactive, suggèrent fortement le diagnostic de SPT. Celui-ci devrait ensuite être confirmé par une biopsie avant que la résection chirurgicale soit effectuée. Chez les enfants, Γ écho graphie abdominale reste la méthode de première intention, suivie par l'IRM comme technique d'imagerie de choix pour évaluer les caractéristiques et l'extension de la lésion, tout en évitant l'exposition des patients aux rayonnements ionisants.
Resumo:
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.
Resumo:
Prior the middle of the 90', interviewing participants in protest events was quiet rare. INdividual SUrveys in RAllies (INSURA) did enter the social researcher's usual toolkit only in the following decade after Favre, Fillieule and Mayer (1997) conducted such a survey with as a primary ambition to build a solid methodological framework that could be subsequently applied by other researchers. After some years of intensive use of INSURA, one is entitled to wonder whether that technique has fulfilled social researchers' hopes or not. In that paper, results of a collective work on alter-global rallies in Evian and Saint- Denis are used to answer three interrelated questions. Firstly, some basic methodological questions about how to collect data on crowds are adressed. What are the specific constraints of interviewing people at the very moment they are "expressing" a political opinion? What specific constraints result from the morphology of the covered events, that is to say, how to build a valid sampling frame? The authors then turn to a more general point about the questions that can be solved, or not, using that technique. Secondly it is the strenghts and weaknesses of INSURA in exploring the transnational dimension of alter global protests that is adressed. The authors show that INSURA is certainly well suited to explore the demographics of alter-global events, as well as relational networks of individuals and multiple belongings. On the contrary, it is assumed that organization networks and movement's boundaries are far more difficult to explore through that method, a fact that seriously limits international cross comparisons of events and movements based on that tool.
Resumo:
Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.
Resumo:
The objective of this work was to combine the advantages of the dried blood spot (DBS) sampling process with the highly sensitive and selective negative-ion chemical ionization tandem mass spectrometry (NICI-MS-MS) to analyze for recent antidepressants including fluoxetine, norfluoxetine, reboxetine, and paroxetine from micro whole blood samples (i.e., 10 microL). Before analysis, DBS samples were punched out, and antidepressants were simultaneously extracted and derivatized in a single step by use of pentafluoropropionic acid anhydride and 0.02% triethylamine in butyl chloride for 30 min at 60 degrees C under ultrasonication. Derivatives were then separated on a gas chromatograph coupled with a triple-quadrupole mass spectrometer operating in negative selected reaction monitoring mode for a total run time of 5 min. To establish the validity of the method, trueness, precision, and selectivity were determined on the basis of the guidelines of the "Société Française des Sciences et des Techniques Pharmaceutiques" (SFSTP). The assay was found to be linear in the concentration ranges 1 to 500 ng mL(-1) for fluoxetine and norfluoxetine and 20 to 500 ng mL(-1) for reboxetine and paroxetine. Despite the small sampling volume, the limit of detection was estimated at 20 pg mL(-1) for all the analytes. The stability of DBS was also evaluated at -20 degrees C, 4 degrees C, 25 degrees C, and 40 degrees C for up to 30 days. Furthermore, the method was successfully applied to a pharmacokinetic investigation performed on a healthy volunteer after oral administration of a single 40-mg dose of fluoxetine. Thus, this validated DBS method combines an extractive-derivative single step with a fast and sensitive GC-NICI-MS-MS technique. Using microliter blood samples, this procedure offers a patient-friendly tool in many biomedical fields such as checking treatment adherence, therapeutic drug monitoring, toxicological analyses, or pharmacokinetic studies.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.