35 resultados para semi-recursive method

em Université de Lausanne, Switzerland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. Methods: During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Results: Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis nor vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis and vertebral fracture (clinical osteoporosis). Conclusion: In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either by changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often used in most of the centers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2±11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis not vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis but vertebral fracture (Clinical osteoporosis). In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either my changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often use in most of the centers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: SIOPEN scoring of 123I mIBG imaging has been shown to predict response to induction chemotherapy and outcome at diagnosis in children with HRN.Method: Patterns of skeletal 123I mIBG uptake were assigned numerical scores (Mscore) ranging from 0 (no metastasis) to 72 (diffuse metastases) within 12 body areas as described previously. 271 anonymised, paired image data sets acquired at diagnosis and on completion of Rapid COJEC induction chemotherapy were reviewed, constituting a representative sample of 1602 children treated prospectively within the HR-NBL1/SIOPEN trial. Pre-and post-treatment Mscores were compared with bone marrow cytology (BM) and 3 year event free survival (EFS).Results: Results 224/271 patients showed skeletal MIBG-uptake at diagnosis and were evaluable forMIBG-response. Complete response (CR) on MIBG to Rapid COJEC induction was achieved by 66%, 34% and 15% of patients who had pre-treatment Mscores of <18 (n¼65, 29%), 18-44 (n¼95,42%) and Y ´ 45 (n¼64, 28.5%) respectively (chi squared test p<.0001). Mscore at diagnosis and on completion of Rapid COJEC correlated strongly with BM involvement (p<0.0001). The correlation of pre score with post scores and response was highly significant (p<0.001). Most importantly, the 3 year EFS in 47 children with Mscore 0 at diagnosis was 0.68 (A ` 0.07), by comparison with 0.42 (A` 0.06), 0.35 (A` 0.05) and 0.25 (A` 0.06) for patients in pre-treatment score groups <18, 18-44 and Y ´ 45, respectively (p<0.001). AnMscore threshold ofY ´ 45 at diagnosis was associated with significantly worse outcome by comparison with all other Mscore groups (p¼0.029). The 3 year EFS of 0.53 (A` 0.07) of patients in metastatic CR (mIBG and BM) after Rapid Cojec (33%) is clearly superior to patients not achieving metastatic CR (0.24 (A ` 0.04), p¼0.005).Conclusion: SIOPEN scoring of 123I mIBG imaging has been shown to predict response to induction chemotherapy and outcome at diagnosis in children with HRN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The goal of this study is to evaluate a T2-mapping sequence by: (i) measuring the reproducibility intra- and inter-observer variability in healthy volunteers in two separate scanning session with a T2 reference phantom; (2) measuring the mean T2 relaxation times by T2-mapping in infarcted myocardium in patients with subacute MI and compare it with patient's the gold standard X-ray coronary angiography and healthy volunteers results. Background. Myocardial edema is a consequence of an inflammation of the tissue, as seen in myocardial infarct (MI). It can be visualized by cardiovascular magnetic resonance (CMR) imaging using the T2 relaxation time. T2-mapping is a quantitative methodology that has the potential to address the limitation of the conventional T2-weighted (T2W) imaging. Methods. The T2-mapping protocol used for all MRI scans consisted in a radial gradient echo acquisition with a lung-liver navigator for free-breathing acquisition and affine image registration. Mid-basal short axis slices were acquired.T2-maps analyses: 2 observers semi- automatically segmented the left ventricle in 6 segments accordingly to the AHA standards. 8 healthy volunteers (age: 27 ± 4 years; 62.5% male) were scanned in 2 separate sessions. 17 patients (age : 61.9 ± 13.9 years; 82.4% male) with subacute STEMI (70.6%) and NSTEMI underwent a T2-mapping scanning session. Results. In healthy volunteers, the mean inter- and intra-observer variability over the entire short axis slice (segment 1 to 6) was 0.1 ms (95% confidence interval (CI): -0.4 to 0.5, p = 0.62) and 0.2 ms (95% CI: -2.8 to 3.2, p = 0.94, respectively. T2 relaxation time measurements with and without the correction of the phantom yielded an average difference of 3.0 ± 1.1 % and 3.1 ± 2.1 % (p = 0.828), respectively. In patients, the inter-observer variability in the entire short axis slice (S1-S6), was 0.3 ms (95% CI: -1.8 to 2.4, p = 0.85). Edema location as determined through the T2-mapping and the coronary artery occlusion as determined on X-ray coronary angiography correlated in 78.6%, but only in 60% in apical infarcts. All except one of the maximal T2 values in infarct patients were greater than the upper limit of the 95% confidence interval for normal myocardium. Conclusions. The T2-mapping methodology is accurate in detecting infarcted, i.e. edematous tissue in patients with subacute infarcts. This study further demonstrated that this T2-mapping technique is reproducible and robust enough to be used on a segmental basis for edema detection without the need of a phantom to yield a T2 correction factor. This new quantitative T2-mapping technique is promising and is likely to allow for serial follow-up studies in patients to improve our knowledge on infarct pathophysiology, on infarct healing, and for the assessment of novel treatment strategies for acute infarctions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A semisupervised support vector machine is presented for the classification of remote sensing images. The method exploits the wealth of unlabeled samples for regularizing the training kernel representation locally by means of cluster kernels. The method learns a suitable kernel directly from the image and thus avoids assuming a priori signal relations by using a predefined kernel structure. Good results are obtained in image classification examples when few labeled samples are available. The method scales almost linearly with the number of unlabeled samples and provides out-of-sample predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The physical disector is a method of choice for estimating unbiased neuron numbers; nevertheless, calibration is needed to evaluate each counting method. The validity of this method can be assessed by comparing the estimated cell number with the true number determined by a direct counting method in serial sections. We reconstructed a 1/5 of rat lumbar dorsal root ganglia taken from two experimental conditions. From each ganglion, images of 200 adjacent semi-thin sections were used to reconstruct a volumetric dataset (stack of voxels). On these stacks the number of sensory neurons was estimated and counted respectively by physical disector and direct counting methods. Also, using the coordinates of nuclei from the direct counting, we simulate, by a Matlab program, disector pairs separated by increasing distances in a ganglion model. The comparison between the results of these approaches clearly demonstrates that the physical disector method provides a valid and reliable estimate of the number of sensory neurons only when the distance between the consecutive disector pairs is 60 microm or smaller. In these conditions the size of error between the results of physical disector and direct counting does not exceed 6%. In contrast when the distance between two pairs is larger than 60 microm (70-200 microm) the size of error increases rapidly to 27%. We conclude that the physical dissector method provides a reliable estimate of the number of rat sensory neurons only when the separating distance between the consecutive dissector pairs is no larger than 60 microm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: b-value is the parameter characterizing the intensity of the diffusion weighting during image acquisition. Data acquisition is usually performed with low b value (b~1000 s/mm2). Evidence shows that high b-values (b>2000 s/mm2) are more sensitive to the slow diffusion compartment (SDC) and maybe more sensitive in detecting white matter (WM) anomalies in schizophrenia.Methods: 12 male patients with schizophrenia (mean age 35 +/-3 years) and 16 healthy male controls matched for age were scanned with a low b-value (1000 s/mm2) and a high b-value (4000 s/mm2) protocol. Apparent diffusion coefficient (ADC) is a measure of the average diffusion distance of water molecules per time unit (mm2/s). ADC maps were generated for all individuals. 8 region of interests (frontal and parietal region bilaterally, centrum semi-ovale bilaterally and anterior and posterior corpus callosum) were manually traced blind to diagnosis.Results: ADC measures acquired with high b-value imaging were more sensitive in detecting differences between schizophrenia patients and healthy controls than low b-value imaging with a gain in significance by a factor of 20- 100 times despite the lower image Signal-to-noise ratio (SNR). Increased ADC was identified in patient's WM (p=0.00015) with major contributions from left and right centrum semi-ovale and to a lesser extent right parietal region.Conclusions: Our results may be related to the sensitivity of high b-value imaging to the SDC believed to reflect mainly the intra-axonal and myelin bound water pool. High b-value imaging might be more sensitive and specific to WM anomalies in schizophrenia than low b-value imaging

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many known examples of multiple semi-independent associations at individual loci; such associations might arise either because of true allelic heterogeneity or because of imperfect tagging of an unobserved causal variant. This phenomenon is of great importance in monogenic traits but has not yet been systematically investigated and quantified in complex-trait genome-wide association studies (GWASs). Here, we describe a multi-SNP association method that estimates the effect of loci harboring multiple association signals by using GWAS summary statistics. Applying the method to a large anthropometric GWAS meta-analysis (from the Genetic Investigation of Anthropometric Traits consortium study), we show that for height, body mass index (BMI), and waist-to-hip ratio (WHR), 3%, 2%, and 1%, respectively, of additional phenotypic variance can be explained on top of the previously reported 10% (height), 1.5% (BMI), and 1% (WHR). The method also permitted a substantial increase (by up to 50%) in the number of loci that replicate in a discovery-validation design. Specifically, we identified 74 loci at which the multi-SNP, a linear combination of SNPs, explains significantly more variance than does the best individual SNP. A detailed analysis of multi-SNPs shows that most of the additional variability explained is derived from SNPs that are not in linkage disequilibrium with the lead SNP, suggesting a major contribution of allelic heterogeneity to the missing heritability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computerized handheld procedure is presented in this paper. It is intended as a database complementary tool, to enhance prospective risk analysis in the field of occupational health. The Pendragon forms software (version 3.2) has been used to implement acquisition procedures on Personal Digital Assistants (PDAs) and to transfer data to a computer in an MS-Access format. The data acquisition strategy proposed relies on the risk assessment method practiced at the Institute of Occupational Health Sciences (IST). It involves the use of a systematic hazard list and semi-quantitative risk assessment scales. A set of 7 modular forms has been developed to cover the basic need of field audits. Despite the minor drawbacks observed, the results obtained so far show that handhelds are adequate to support field risk assessment and follow-up activities. Further improvements must still be made in order to increase the tool effectiveness and field adequacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dispersal mechanisms and competition together play a key role in the spatial distribution of a population. Species that disperse via fission are likely to experience high levels of localized competitive pressure from conspecifics relative to species that disperse in other ways. Although fission dispersal occurs in many species, its ecological and behavioural effects remain unclear. We compared foraging effort, nest spatial distribution and aggression of two sympatric ant species that differ in reproductive dispersal: Streblognathus peetersi, which disperse by group fission, and Plectroctena mandibularis, which disperse by solitary wingless queens. We found that although both species share space and have similar foraging strategies, they differ in nest distribution and aggressive behaviour. The spatial distribution of S. peetersi nests was extremely aggregated, and workers were less aggressive towards conspecifics from nearby nests than towards distant conspecifics and all heterospecific workers. By contrast, the spatial distribution of P. mandibularis nests was overdispersed, and workers were equally aggressive towards conspecific and heterospecific competitors regardless of nest distance. Finally, laboratory experiments showed that familiarity led to the positive relationship between aggression and nest distance in S. peetersi. While unfamiliar individuals were initially aggressive, the level of aggression decreased within 1 h of contact, and continued to decrease over 24 h. Furthermore, individuals from near nests that were not aggressive could be induced to aggression after prolonged isolation. Overall, these results suggest that low aggression mediated by familiarity could provide benefits for a species with fission reproduction and an aggregated spatial distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Q-sort is a research method which allows defining profiles of attitudes toward a set of statements, ordered in relation to each other. Pertaining to the Q Methodology, the qualitative analysis of the Q-sorts is based on quantitative techniques. This method is of particular interest for research in health professions, a field in which attitudes of patients and professionals are very important. The method is presented in this article, along with an example of application in nursing in old age psychiatry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contemporary society, religious signification and secular systems mix and influence each other. Holistic conceptions of a world in which man is integrated harmoniously with nature meet representations of a world run by an immanent God. On the market of the various systems, the individual goes from one system to another, following his immediate needs and expectations without necessarily leaving any marks in a meaningful long term system. This article presents the first results of an ongoing research in Switzerland on contemporary religion focusing on (new) paths of socialization of modern that individuals and the various (non-) belief systems that they simultaneously develop