2 resultados para robotic manipulation

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. Aim. To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. Materials and methods. A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. Results. Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. Conclusions. Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.