4 resultados para repeated measures

em Université de Lausanne, Switzerland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reduced re'nal function has been reported with tenofovir disoproxil fumarate (TDF). It is not clear whether TDF co-administered with a boosted protease inhibitor (PI) leads to a greater decline in renal function than TDF co-administered with a non-nucleoside reverse transcriptase inhibitor (NNRTI).Methods: We selected ail antiretroviral therapy-naive patients in the Swiss HIV Cohort Study (SHCS) with calibrated or corrected serum creatinine measurements starting antiretroviral therapy with TDF and either efavirenz (EFV) or the ritonavir-boosted PIs, lopinavir (LPV/r) or atazanavir (ATV/r). As a measure of renal function, we used the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation to estimate the glomerular filtration rate (eGFR). We calculated the difference in eGFR over time between two therapies using a marginal model for repeated measures. In weighted analyses, observations were weighted by the product of their point of treatment and censoring weights to adjust for differences both in the sort of patients starting each therapy and in the sort of patients remaining on each therapy over time.Results: By March 2011, 940 patients with at least one creatinine measurement on a first therapy with either TDF and EFV (n=484), TDF and LPVlr (n=269) or TDF and ATV/r (n=187) had been followed for a median of 1. 7, 1.2 and 1.3 years, respectively. Table 1 shows the difference in average estimated GFR (eGFR) over time since starting cART for two marginal models. The first model was not adjusted for potential confounders; the second mode! used weights to adjust for confounders. The results suggest a greater decline in renal function during the first 6 months if TDF is used with a PI rather than with an NNRTI, but no further difference between these therapies after the first 6 months. TDF and ATV/r may lead to a greater decline in the first 6 months than TDF and LPVlr.Conclusions: TDF co-administered with a boosted PI leads to a greater de cline in renal function over the first 6 months of therapy than TDF co-administered with an NNRTI; this decline may be worse with ATV/r than with LPV/r.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: In extreme situations, such as hyperacute rejection of heart transplant or major bleeding per-operating complications, an urgent heart explantation might be the only means of survival. The aim of this experimental study was to improve the surgical technique and the hemodynamics of an Extracorporeal Membrane Oxygenation (ECMO) support through a peripheral vascular access in an acardia model. Methods: An ECMO support was established in 7 bovine experiments (59±6.1 kg) by the transjugular insertion to the caval axis of a self-expanded cannula, with return through a carotid artery. After baseline measurements of pump flow and arterial and central venous pressure, ventricular fibrillation was induced (B), the great arteries were clamped, the heart was excised and right and left atria remnants, containing the pulmonary veins, were sutured together leaving an atrial septal defect (ASD) over the cannula in the caval axis. Measurements were taken with the pulmonary artery (PA) clamped (C) and anastomosed with the caval axis (D). Regular arterial and central venous blood gases tests were performed. The ANOVA test for repeated measures was used to test the null hypothesis and a Bonferroni t method for assessing the significance in the between groups pairwise comparison of mean pump flow. Results: Initial pump flow (A) was 4.3±0.6 L/min dropping to 2.8±0.7 L/min (P B-A= 0.003) 10 minutes after induction of ventricular fibrillation (B). After cardiectomy, with the pulmonary artery clamped (C) it augmented not significantly to 3.5±0.8 L/min (P C-B= 0.33, P C-A= 0.029). Finally, PA anastomosis to the caval axis was followed by an almost to baseline pump flow augmentation (4.1±0.7 L/min, P D-B= 0.009, P D-C= 0.006, P D-A= 0.597), permitting a full ECMO support in acardia by a peripheral vascular access. Conclusions: ECMO support in acardia is feasible, providing new opportunities in situations where heart must urgently be explanted, as in hyperacute rejection of heart transplant. Adequate drainage of pulmonary circulation is pivotal in order to avoid pulmonary congestion and loss of volume from the normal right to left shunt of bronchial vessels. Furthermore, the PA anastomosis to the caval axis not only improves pump flow but it also permits an ECMO support by a peripheral vascular access and the closure of the chest.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT: In order to evaluate the one-year evolution of web-based information on alcohol dependence, we re-assessed alcohol-related sites in July 2007 with the same evaluating tool that had been used to assess these sites in June 2006. Websites were assessed with a standardized form designed to rate sites on the basis of accountability, presentation, interactivity, readability, and content quality. The DISCERN scale was also used, which aimed to assist persons without content expertise in assessing the quality of written health publications. Scores were highly stable for all components of the form one year later (r = .77 to .95, p &lt; .01). Analysis of variance for repeated measures showed no time effect, no interaction between time and scale, no interaction between time and group (affiliation categories), and no interaction between time, group, and scale. The study highlights lack of change of alcohol-dependence-related web pages across one year.