28 resultados para relative static method
em Université de Lausanne, Switzerland
Resumo:
Background: Prognostic and predictive markers are of great importance for future study designs and essential for the interpretation of clinical trials incorporating an EGFR-inhibitor. The current study prospectively assessed and validated KRAS, BRAF and PIK3CA mutations in rectal cancer patients screened for the trial SAKK41/07 of concomitant preoperative radio-chemotherapy with or without panitumumab.Methods: Macrodissection was performed on pretreatment formalin fixed paraffin embedded biopsy tissue sections to arrive at a minimum of 50% of tumor cells. DNA was extracted with the Maxwell 16 FFPE Tissue LEV DNA purification kit. After PCR amplification, mutations were identified by pyrosequencing. We prospectively analysed pretreatment biopsy material from 149 rectal cancer pts biopsies for KRAS (exon 2 codon 12 [2-12] and 13 [2-13], exon 3 codon 59 [3-59]) and 61 [3-61], exon 4 codon 117 [4-117] and 146 [4-146]). Sixty-eight pts (KRASwt exon 2, 3 only) were further analysed for BRAF (exon 15 codon 600) and PIK3CA (exon 9 codon 542, 545 and 546, exon 20 codon 1043 [20-1043] and 1047 [20-1047]) mutations, and EGFR copy number by qPCR. For the calculation of the EGFR copy number, we used KRAS copy number as internal reference standard. The calculation was done on the basis of the two standard curves relative quantification method.Results: In 149 screened pts with rectal cancer, the prevalence of KRAS mutations was 36%. Among the 68 pts enrolled in SAKK 41/07 based on initially presumed KRASwt status (exon 2/codons 12+13), 18 pts (26%) had a total of 23 mutations in the RAS/PIK3CA-pathways upon validation analysis. Twelve pts had a KRAS mutation, 7 pts had a PIK3CA mutation, 3 pts had a NRAS mutation, 1 patient a BRAF mutation. Surprisingly, five of these pts had double- mutations, including 4 pts with KRAS plus PIK3CA mutations, and 1 pt with NRAS plus PIK3CA mutations. The median normalized EGFR copy number was 1. Neither mutations of KRAS, BRAF, and PIK3CA, nor EGFR copy number were statistically associated with the primary study endpoint pCR (pathological complete regression).Conclusions: The prevalence of KRAS mutations in rectal and in colon cancer appears to be similar. BRAF mutations are rare; PIK3CA mutations are more common (10%). EGFR copy number is not increased in rectal cancer. A considerable number or KRAS exon 2 wt tumors harbored KRAS exon 3+4 mutations. Further study is needed to determine if KRAS testing should include exons 2-4.
Resumo:
Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating for camera saturation which takes into account the variable activity in the field of view, i.e. time-dependent dead-time effects. The algorithm presented here accomplishes this task.
Resumo:
Dispersal mechanisms and competition together play a key role in the spatial distribution of a population. Species that disperse via fission are likely to experience high levels of localized competitive pressure from conspecifics relative to species that disperse in other ways. Although fission dispersal occurs in many species, its ecological and behavioural effects remain unclear. We compared foraging effort, nest spatial distribution and aggression of two sympatric ant species that differ in reproductive dispersal: Streblognathus peetersi, which disperse by group fission, and Plectroctena mandibularis, which disperse by solitary wingless queens. We found that although both species share space and have similar foraging strategies, they differ in nest distribution and aggressive behaviour. The spatial distribution of S. peetersi nests was extremely aggregated, and workers were less aggressive towards conspecifics from nearby nests than towards distant conspecifics and all heterospecific workers. By contrast, the spatial distribution of P. mandibularis nests was overdispersed, and workers were equally aggressive towards conspecific and heterospecific competitors regardless of nest distance. Finally, laboratory experiments showed that familiarity led to the positive relationship between aggression and nest distance in S. peetersi. While unfamiliar individuals were initially aggressive, the level of aggression decreased within 1 h of contact, and continued to decrease over 24 h. Furthermore, individuals from near nests that were not aggressive could be induced to aggression after prolonged isolation. Overall, these results suggest that low aggression mediated by familiarity could provide benefits for a species with fission reproduction and an aggregated spatial distribution.
Long-term fluctuation of relative afferent pupillary defect in subjects with normal visual function.
Resumo:
PURPOSE: To determine whether the relative afferent pupillary defect (RAPD) remains constant over time in normal subjects. METHODS: Seventeen normal subjects were tested with infrared pupillography and automated perimetry in four sessions over 3 years. The changes in RAPD and visual field asymmetry between testing sessions were compared. RESULTS: The range of RAPD was 0.0 to 0.3 log unit, and the difference in the mean deviation between the eyes on automated static perimetry was 0 to 3 dB. Eight subjects repeatedly had an RAPD in the same eye. There was no correlation between the RAPD and the visual field asymmetry at the same visit. Changes in the magnitude of the RAPD between any two sessions were typically small (median, 0.08 log unit; 25th percentile, 0.04 log unit; 75th percentile, 0.15 log unit). CONCLUSIONS: Some normal subjects may show a persistent but small RAPD in the absence of detectable pathologic disease. Therefore, an isolated RAPD in the range of 0.3 log unit that is not associated with any other significant historical or clinical finding should probably be considered benign.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
MOTIVATION: Microarray results accumulated in public repositories are widely reused in meta-analytical studies and secondary databases. The quality of the data obtained with this technology varies from experiment to experiment, and an efficient method for quality assessment is necessary to ensure their reliability. RESULTS: The lack of a good benchmark has hampered evaluation of existing methods for quality control. In this study, we propose a new independent quality metric that is based on evolutionary conservation of expression profiles. We show, using 11 large organ-specific datasets, that IQRray, a new quality metrics developed by us, exhibits the highest correlation with this reference metric, among 14 metrics tested. IQRray outperforms other methods in identification of poor quality arrays in datasets composed of arrays from many independent experiments. In contrast, the performance of methods designed for detecting outliers in a single experiment like Normalized Unscaled Standard Error and Relative Log Expression was low because of the inability of these methods to detect datasets containing only low-quality arrays and because the scores cannot be directly compared between experiments. AVAILABILITY AND IMPLEMENTATION: The R implementation of IQRray is available at: ftp://lausanne.isb-sib.ch/pub/databases/Bgee/general/IQRray.R. CONTACT: Marta.Rosikiewicz@unil.ch SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Resumo:
Metabolic labeling techniques have recently become popular tools for the quantitative profiling of proteomes. Classical stable isotope labeling with amino acids in cell cultures (SILAC) uses pairs of heavy/light isotopic forms of amino acids to introduce predictable mass differences in protein samples to be compared. After proteolysis, pairs of cognate precursor peptides can be correlated, and their intensities can be used for mass spectrometry-based relative protein quantification. We present an alternative SILAC approach by which two cell cultures are grown in media containing isobaric forms of amino acids, labeled either with 13C on the carbonyl (C-1) carbon or 15N on backbone nitrogen. Labeled peptides from both samples have the same nominal mass and nearly identical MS/MS spectra but generate upon fragmentation distinct immonium ions separated by 1 amu. When labeled protein samples are mixed, the intensities of these immonium ions can be used for the relative quantification of the parent proteins. We validated the labeling of cellular proteins with valine, isoleucine, and leucine with coverage of 97% of all tryptic peptides. We improved the sensitivity for the detection of the quantification ions on a pulsing instrument by using a specific fast scan event. The analysis of a protein mixture with a known heavy/light ratio showed reliable quantification. Finally the application of the technique to the analysis of two melanoma cell lines yielded quantitative data consistent with those obtained by a classical two-dimensional DIGE analysis of the same samples. Our method combines the features of the SILAC technique with the advantages of isobaric labeling schemes like iTRAQ. We discuss advantages and disadvantages of isobaric SILAC with immonium ion splitting as well as possible ways to improve it
Resumo:
The ancient Greek medical theory based on balance or imbalance of humors disappeared in the western world, but does survive elsewhere. Is this survival related to a certain degree of health care efficiency? We explored this hypothesis through a study of classical Greco-Arab medicine in Mauritania. Modern general practitioners evaluated the safety and effectiveness of classical Arabic medicine in a Mauritanian traditional clinic, with a prognosis/follow-up method allowing the following comparisons: (i) actual patient progress (clinical outcome) compared with what the traditional 'tabib' had anticipated (= prognostic ability) and (ii) patient progress compared with what could be hoped for if the patient were treated by a modern physician in the same neighborhood. The practice appeared fairly safe and, on average, clinical outcome was similar to what could be expected with modern medicine. In some cases, patient progress was better than expected. The ability to correctly predict an individual's clinical outcome did not seem to be better along modern or Greco-Arab theories. Weekly joint meetings (modern and traditional practitioners) were spontaneously organized with a modern health centre in the neighborhood. Practitioners of a different medical system can predict patient progress. For the patient, avoiding false expectations with health care and ensuring appropriate referral may be the most important. Prognosis and outcome studies such as the one presented here may help to develop institutions where patients find support in making their choices, not only among several treatment options, but also among several medical systems.
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 microm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (> 200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m(3))
Resumo:
Axial deflection of DNA molecules in solution results from thermal motion and intrinsic curvature related to the DNA sequence. In order to measure directly the contribution of thermal motion we constructed intrinsically straight DNA molecules and measured their persistence length by cryo-electron microscopy. The persistence length of such intrinsically straight DNA molecules suspended in thin layers of cryo-vitrified solutions is about 80 nm. In order to test our experimental approach, we measured the apparent persistence length of DNA molecules with natural "random" sequences. The result of about 45 nm is consistent with the generally accepted value of the apparent persistence length of natural DNA sequences. By comparing the apparent persistence length to intrinsically straight DNA with that of natural DNA, it is possible to determine both the dynamic and the static contributions to the apparent persistence length.
Resumo:
We studied the response to F+0 renography and the relative and absolute individual kidney function in neonates and < 6-mo-old infants before and after surgery for unilateral ureteropelvic junction obstruction (UJO). METHODS: The results obtained at diagnosis and after pyeloplasty for 9 children (8 boys, 1 girl; age range, 0.8-5.9 mo; mean age +/- SD, 2.4 +/- 1.5 mo) with proven unilateral UJO (i.e., affected kidney [AK]) and an unremarkable contralateral kidney (i.e., normal kidney [NK]) were evaluated and compared with a control group of 10 children (6 boys, 4 girls; age range, 0.8-2.8 mo; mean age, 1.5 +/- 0.7 mo) selected because of symmetric renal function, absence of vesicoureteral reflux or infection, and an initially dilated but not obstructed renal pelvis as proven by follow-up. Renography was performed for 20 min after injection of (123)I-hippuran (OIH) (0.5-1.0 MBq/kg) immediately followed by furosemide (1 mg/kg). The relative and absolute renal functions and the response to furosemide were measured on background-subtracted and depth-corrected renograms. The response to furosemide was quantified by an elimination index (EI), defined as the ratio of the 3- to 20-min activities: An EI > or = 3 was considered definitively normal and an EI < or = 1 definitively abnormal. If EI was equivocal (1 < EI < 3), the response to gravity-assisted drainage was used to differentiate AKs from NKs. Absolute separate renal function was measured by an accumulation index (AI), defined as the percentage of (123)I-OIH (%ID) extracted by the kidney 30-90 s after maximal cardiac activity. RESULTS: All AKs had definitively abnormal EIs at diagnosis (mean, 0.56 +/- 0.12) and were significantly lower than the EIs of the NKs (mean, 3.24 +/- 1.88) and of the 20 control kidneys (mean, 3.81 +/- 1.97; P < 0.001). The EIs of the AKs significantly improved (mean, 2.81 +/- 0.64; P < 0.05) after pyeloplasty. At diagnosis, the AIs of the AKs were significantly lower (mean, 6.31 +/- 2.33 %ID) than the AIs of the NKs (mean, 9.43 +/- 1.12 %ID) and of the control kidneys (mean, 9.05 +/- 1.17 %ID; P < 0.05). The AIs of the AKs increased at follow-up (mean, 7.81 +/- 2.23 %ID) but remained lower than those of the NKs (mean, 10.75 +/- 1.35 %ID; P < 0.05). CONCLUSION: In neonates and infants younger than 6 mo, (123)I-OIH renography with early furosemide injection (F+0) allowed us to reliably diagnose AKs and to determine if parenchymal function was normal or impaired and if it improved after surgery.
A New Method for ECG Tracking of Persistent Atrial Fibrillation Termination during Stepwise Ablation
Resumo:
Stepwise radiofrequency catheter ablation (step-CA) has become the treatment of choice for the restoration of sinus rhythm (SR) in patients with long-standing persistent atrial fibrillation (pers-AF). Its success rate appears limited as the amount of ablation to achieve long term SR is unknown. Multiple organization indexes (OIs) have been previously developed to track the organization of AF during step-CA, however, with limited success. We report an adaptive method for tracking AF termination (AF-term) based on OIs characterizing the relationship between harmonic components of atrial activity from the surface ECG of AF activity. By computing their relative evolution during the last two steps preceding AF-term, we found that the performance of our OIs was superior to classical indices to track the efficiency of step-CA "en route" to AF-term. Our preliminary results suggest that the gradual synchronization between the fundamental and its first harmonic of AF activity appears as a promising parameter for predicting AF-term during step-CA.
Resumo:
Selective pressures related to gene function and chromosomal architecture are acting on genome sequences and can be revealed, for instance, by appropriate genometric methods. Cumulative nucleotide skew analyses, i.e., GC, TA, and ORF orientation skews, predict the location of the origin of DNA replication for 88 out of 100 completely sequenced bacterial chromosomes. These methods appear fully reliable for proteobacteria, Gram-positives, and spirochetes as well as for euryarchaeotes. Based on this genome architecture information, coorientation analyses reveal that in prokaryotes, ribosomal RNA (rRNA) genes encoding the small and large ribosomal subunits are all transcribed in the same direction as DNA replication; that is, they are located along the leading strand. This result offers a simple and reliable method for circumscribing the region containing the origin of the DNA replication and reveals a strong selective pressure acting on the orientation of rRNA genes similar to the weaker one acting on the orientation of ORFs. Rate of coorientation of transfer RNA (tRNA) genes with DNA replication appears to be taxon-specific. Analyzing nucleotide biases such as GC and TA skews of genes and plotting one against the other reveals a taxonomic clusterization of species. All ribosomal RNA genes are enriched in Gs and depleted in Cs, the only so far known exception being the rRNA genes of deuterostomian mitochondria. However, this exception can be explained by the fact that in the chromosome of the human mitochondrion, the model of the deuterostomian organelle genome, DNA replication, and rRNA transcription proceed in opposite directions. A general rule is deduced from prokaryotic and mitochondrial genomes: ribosomal RNA genes that are transcribed in the same direction as the DNA replication are enriched in Gs, and those transcribed in the opposite direction are depleted in Gs.
Resumo:
BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
A filtering method to correct time-lapse 3D ERT data and improve imaging of natural aquifer dynamics
Resumo:
We have developed a processing methodology that allows crosshole ERT (electrical resistivity tomography) monitoring data to be used to derive temporal fluctuations of groundwater electrical resistivity and thereby characterize the dynamics of groundwater in a gravel aquifer as it is infiltrated by river water. Temporal variations of the raw ERT apparent-resistivity data were mainly sensitive to the resistivity (salinity), temperature and height of the groundwater, with the relative contributions of these effects depending on the time and the electrode configuration. To resolve the changes in groundwater resistivity, we first expressed fluctuations of temperature-detrended apparent-resistivity data as linear superpositions of (i) time series of riverwater-resistivity variations convolved with suitable filter functions and (ii) linear and quadratic representations of river-water-height variations multiplied by appropriate sensitivity factors; river-water height was determined to be a reliable proxy for groundwater height. Individual filter functions and sensitivity factors were obtained for each electrode configuration via deconvolution using a one month calibration period and then the predicted contributions related to changes in water height were removed prior to inversion of the temperature-detrended apparent-resistivity data. Applications of the filter functions and sensitivity factors accurately predicted the apparent-resistivity variations (the correlation coefficient was 0.98). Furthermore, the filtered ERT monitoring data and resultant time-lapse resistivity models correlated closely with independently measured groundwater electrical resistivity monitoring data and only weakly with the groundwater-height fluctuations. The inversion results based on the filtered ERT data also showed significantly less inversion artefacts than the raw data inversions. We observed resistivity increases of up to 10% and the arrival time peaks in the time-lapse resistivity models matched those in the groundwater resistivity monitoring data.