52 resultados para rail transit

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Electrical stimulation is a new way to treat digestive disorders such as constipation. Colonic propulsive activity can be triggered by battery operated devices. This study aimed to demonstrate the effect of direct electrical colonic stimulation on mean transit time in a chronic porcine model. The impact of stimulation and implanted material on the colonic wall was also assessed. Three pairs of electrodes were implanted into the caecal wall of 12 anaesthetized pigs. Reference colonic transit time was determined by radiopaque markers for each pig before implantation. It was repeated 4 weeks after implantation with sham stimulation and 5 weeks after implantation with electrical stimulation. Aboral sequential trains of 1-ms pulse width (10 V; 120 Hz) were applied twice daily for 6 days, using an external battery operated stimulator. For each course of markers, a mean value was computed from transit times obtained from individual pig. Microscopic examination of the caecum was routinely performed after animal sacrifice. A reduction of mean transit time was observed after electrical stimulation (19 +/- 13 h; mean +/- SD) when compared to reference (34 +/- 7 h; P = 0.045) and mean transit time after sham stimulation (36 +/- 9 h; P = 0.035). Histological examination revealed minimal chronic inflammation around the electrodes. Colonic transit time measured in a chronic porcine model is reduced by direct sequential electrical stimulation. Minimal tissue lesion is elicited by stimulation or implanted material. Electrical colonic stimulation could be a promising approach to treat specific disorders of the large bowel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Introduction : La stimulation électrique représente une nouvelle modalité thérapeutique de divers troubles digestifs. Dans la constipation par exemple, le péristaltisme colique peut être activé par un système électrique alimenté par une batterie. La présente étude a pour but de démontrer l'impact d'une stimulation électrique directe du côlon sur le temps de transit moyen, en utilisant un modèle expérimental chronique porcin. L'effet de la stimulation et du matériel implanté dans la paroi colique est également évalué. Matériel et méthode : Trois paires d'électrodes ont été implantées dans la paroi cæcale de douze porcs anesthésiés. Avant implantation, un temps de transit colique de référence a été déterminé chez chaque animal par utilisation de marqueurs radio-opaques. Cette évaluation a été répétée quatre semaines après implantation, sous stimulation factice, et cinq semaines après implantation, sous stimulation électrique. Des trains séquentiels et aboraux de stimulation (10 V ; 120 Hz ; 1 ms) ont été appliqués quotidiennement durant six jours, en utilisant un stimulateur externe fonctionnant sur batteries. Pour chaque série de marqueurs, une valeur moyenne a été calculée à partir du temps de transit individuel des porcs. Un examen microscopique du cæcum a été systématiquement entrepris après sacrifice des animaux. Résultats : Une réduction du temps de transit moyen a été observée après stimulation électrique (19h ± 13 ; moyenne ± DS), comparativement au temps de référence (34h ± 7 ; p=0.045) et au temps de transit après stimulation factice (36h ± 9 ; p=0.035). L'examen histologique a montré la présence d'une inflammation chronique minime, autour des électrodes. Conclusion : Le temps de transit colique porcin peut être réduit, en conditions expérimentales chroniques, par une stimulation électrique directe et séquentielle de l'intestin. Des lésions tissulaires limitées ont été occasionnées par la stimulation ou le matériel implanté. La stimulation électrique colique représente certainement une approche prometteuse du traitement de certains troubles spécifiques du côlon, avant tout fonctionnels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Introduction : La stimulation électrique représente une nouvelle modalité thérapeutique de divers troubles digestifs. Dans la constipation par exemple, le péristaltisme colique peut être activé par un système électrique alimenté par une batterie. La présente étude a pour but de démontrer l'impact d'une stimulation électrique directe du côlon sur le temps de transit moyen, en utilisant un modèle expérimental chronique porcin. L'effet de la stimulation et du matériel implanté dans la paroi colique est également évalué. Matériel et méthode : Trois paires d'électrodes ont été implantées dans la paroi cæcale de douze porcs anesthésiés. Avant implantation, un temps de transit colique de référence a été déterminé chez chaque animal par utilisation de marqueurs radio-opaques. Cette évaluation a été répétée quatre semaines après implantation, sous stimulation factice, et cinq semaines après implantation, sous stimulation électrique. Des trains séquentiels et aboraux de stimulation (10 V ; 120 Hz ; 1 ms) ont été appliqués quotidiennement durant six jours, en utilisant un stimulateur externe fonctionnant sur batteries. Pour chaque série de marqueurs, une valeur moyenne a été calculée à partir du temps de transit individuel des porcs. Un examen microscopique du cæcum a été systématiquement entrepris après sacrifice des animaux. Résultats : Une réduction du temps de transit moyen a été observée après stimulation électrique (19h ± 13 ; moyenne ± DS), comparativement au temps de référence (34h ± 7 ; p=0.045) et au temps de transit après stimulation factice (36h ± 9 ; p=0.035). L'examen histologique a montré la présence d'une inflammation chronique minime, autour des électrodes. Conclusion : Le temps de transit colique porcin peut être réduit, en conditions expérimentales chroniques, par une stimulation électrique directe et séquentielle de l'intestin. Des lésions tissulaires limitées ont été occasionnées par la stimulation ou le matériel implanté. La stimulation électrique colique représente certainement une approche prometteuse du traitement de certains troubles spécifiques du côlon, avant tout fonctionnels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background, aim, and scope A coupled Life Cycle Costing and life cycle assessment has been performed for car-bodies of the Korean Tilting Train eXpress (TTX) project using European and Korean databases, with the objective of assessing environmental and cost performance to aid materials and process selection. More specifically, the potential of polymer composite car-body structures for the Korean Tilting Train eXpress (TTX) has been investigated. Materials and methods This assessment includes the cost of both carriage manufacturing and use phases, coupled with the life cycle environmental impacts of all stages from raw material production, through carriage manufacture and use, to end-of-life scenarios. Metallic carriages were compared with two composite options: hybrid steel-composite and full-composite carriages. The total planned production for this regional Korean train was 440 cars, with an annual production volume of 80 cars. Results and discussion The coupled analyses were used to generate plots of cost versus energy consumption and environmental impacts. The results show that the raw material and manufacturing phase costs are approximately half of the total life cycle costs, whilst their environmental impact is relatively insignificant (3-8%). The use phase of the car-body has the largest environmental impact for all scenarios, with near negligible contributions from the other phases. Since steel rail carriages weigh more (27-51%), the use phase cost is correspondingly higher, resulting in both the greatest environmental impact and the highest life cycle cost. Compared to the steel scenario, the hybrid composite variant has a lower life cycle cost (16%) and a lower environmental impact (26%). Though the full composite rail carriage may have the highest manufacturing cost, it results in the lowest total life cycle costs and lowest environmental impacts. Conclusions and recommendations This coupled cost and life cycle assessment showed that the full composite variant was the optimum solution. This case study showed that coupling of technical cost models with life cycle assessment offers an efficient route to accurately evaluate economic and environmental performance in a consistent way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sleep spindles are synchronized 11-15 Hz electroencephalographic (EEG) oscillations predominant during nonrapid-eye-movement sleep (NREMS). Rhythmic bursting in the reticular thalamic nucleus (nRt), arising from interplay between Ca(v)3.3-type Ca(2+) channels and Ca(2+)-dependent small-conductance-type 2 (SK2) K(+) channels, underlies spindle generation. Correlative evidence indicates that spindles contribute to memory consolidation and protection against environmental noise in human NREMS. Here, we describe a molecular mechanism through which spindle power is selectively extended and we probed the actions of intensified spindling in the naturally sleeping mouse. Using electrophysiological recordings in acute brain slices from SK2 channel-overexpressing (SK2-OE) mice, we found that nRt bursting was potentiated and thalamic circuit oscillations were prolonged. Moreover, nRt cells showed greater resilience to transit from burst to tonic discharge in response to gradual depolarization, mimicking transitions out of NREMS. Compared with wild-type littermates, chronic EEG recordings of SK2-OE mice contained less fragmented NREMS, while the NREMS EEG power spectrum was conserved. Furthermore, EEG spindle activity was prolonged at NREMS exit. Finally, when exposed to white noise, SK2-OE mice needed stronger stimuli to arouse. Increased nRt bursting thus strengthens spindles and improves sleep quality through mechanisms independent of EEG slow waves (<4 Hz), suggesting SK2 signaling as a new potential therapeutic target for sleep disorders and for neuropsychiatric diseases accompanied by weakened sleep spindles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de synthèse : Le Magnet Tracking System (MTS) est une technique peu invasive d'investigation de la motilité de l'entier du tube digestif. Elle repose sur le suivi de la progression d'un aimant par des senseurs externes en temps réel et dans les 3 dimensions. Dans cette étude, le MTS a été utilisé pour étudier les caractéristiques de propulsion propres aux différents segments coliques ainsi que pour comparer le transit de l'aimant permanent du MTS à celui de marqueurs radioopaques habituellement utilisés. Dix hommes et 10 femmes ayant un transit gastro-intestinal régulier ont ingéré simultanément un aimant de MTS et une capsule contenant 10 marqueurs radio-opaques, à 20h00. Les enregistrements se sont ensuite déroulés sur 2 matinées successives de 5 heures. L'analyse des données brutes recueillies a permis de réaliser une projection spatio-temporelle de la trajectoire de l'aimant dans le tube digestif ainsi qu'une description précise de l'origine, de la direction, de l'amplitude et de la vitesse des mouvements coliques. Des radiographies d'abdomen ont permis de comparer les positions respectives des marqueurs radio-opaques et de l'aimant du MTS. Durant 90% du temps d'enregistrement, l'aimant était immobile ou présentait des mouvements alternatifs de faible amplitude. Le reste des enregistrements consiste en activité propulsive dont 20% représentent des déplacements rétrogrades et une description très précise de 34 mouvements de masses. L'analyse des déplacements démontre une distribution bimodales des vitesses voisine de 1.5 et 50 cm /min, ce tant en direction orale que caudale. Deux tiers des distances parcourues le sont à vitesse rapide. L'analyse segmentaire confirme une progression horaire absolue supérieure dans le côlon gauche que droit. L'analyse détaillée par segment colique, reposant sur la description des déplacements enregistrés correspond aux rôles reconnus des différents segments, notamment de aire de stockage et de conditionnement du côlon ascendant ou de transit du côlon descendant. La comparaison des 2 sexes démontre un nombre plus important de mouvements, particulièrement de mouvements de masse chez l'homme. Les radiographies montrent une bonne corrélation entre la position de l'aimant et celle des marqueurs radio-opaques. Le MTS permet ainsi une description précise des caractéristiques propulsives des différents segments coliques, notamment par l'analyse détaillée des progressions à vitesses lente et rapide et leurs directions. Des distinctions peuvent également être notées en fonction du sexe. Ces investigations offrent de nouvelles perspectives pour l'étude des troubles de la motilité digestive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Resection of lung metastases (LM) from colorectal cancer (CRC)¦is increasingly performed with a curative intent.Most series report small groups¦of patients, and it is currently not possible to identify those CRC patients who¦may benefit the most of surgical management. It is clinically relevant to assess¦risk factors for prolonged survival after this type of procedures.¦Methods: A meta analysis of 24 series published between 2000 and 2011¦which focused on surgical management of LM from CRC and included more¦than 40 patients each, with or without prior resection of in transit liver¦metastases. Random effects were calculated for five variables considered as¦potential prognostic factors.¦Results: A total of 2815 patients who underwent surgery with a curative¦intent were considered in this analysis. Four parameters were associated with¦a decreased survival: 1) a short disease-free interval between primary tumor¦resection and development of LM (HR = 1·59, 95% CI 1·27-1·98); 2) multiple¦LM (HR = 2·04, 95%CI 1·72-2·41); 3) positive hilar/mediastinal lymph nodes¦(HR = 1·65, 95% CI 1·35-2·02); and 4) a high prethoracotomy CEA value (HR¦=1·91, 95% CI 1·57-2·32). By comparison, a history of resected liver metastases¦(HR = 1·36, 95% CI 0·92-2·03) did not achieve statistical significance.¦Conclusion: Risk factors for poor clinical outcome after surgery for lung¦metastases in CRC patients include: 1) synchronous lung metastases; 2) high¦pre-thoracotomy CEA; 3) hilar nodes involvement; and 4) multiple pulmonary¦lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Patients with primary cutaneous melanoma > or = 1.5 mm in thickness are at high risk of having regional micrometastases at the time of initial surgical treatment. A phase III international study was designed to evaluate whether prophylactic isolated limb perfusion (ILP) could prevent regional recurrence and influence survival. PATIENTS AND METHODS: A total of 832 assessable patients from 16 centers entered the study; 412 were randomized to wide excision (WE) only and 420 to WE plus ILP with melphalan and mild hyperthermia. Median age was 50 years, 68% of patients were female, 79% of melanomas were located on a lower limb, and 47% had a thickness > or = 3 mm. RESULTS: Median follow-up duration is 6.4 years. There was a trend for a longer disease-free interval (DFI) after ILP. The difference was significant for patients who did not undergo elective lymph node dissection (ELND). The impact of ILP was clearly on the occurrence-as first site of progression - of in-transit metastases (ITM), which were reduced from 6.6% to 3.3%, and of regional lymph node (RLN) metastases, with a reduction from 16.7% to 12.6%. There was no benefit from ILP in terms of time to distant metastasis or survival. Side effects were higher after ILP, but transient in most patients. There were two amputations for limb toxicity after ILP. CONCLUSION: Prophylactic ILP with melphalan cannot be recommended as an adjunct to standard surgery in high-risk primary limb melanoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de Synthèse : Introduction : Depuis plus de 50 ans, les fistules artérioveineuses radiocéphaliques (FAV) restent le meilleur accès d'hémodialyse en termes de perméabilité et de complications. Néanmoins, l'échec précoce dû aux thromboses ou à la non maturation entraîne leur abandon chez un nombre significatif de patients. Cette étude prospective est destinée à investiguer la mesure peropératoire du débit sanguin dans les FAV comme valeur prédictive d'échec précoce. Méthode : Nous avons sélectionné des patients nécessitant la confection d'une FAV pour hémodialyse en se basant sur le repérage veineux effectué par ultrason dans la période préopératoire. La mesure du débit sanguin dans la FAV a été réalisée systématiquement après la réalisation de l'anastomose en utilisant une sonde mesurant le temps de transit des globules rouges. Durant le suivi, le débit a été estimé par ultrason à des intervalles réguliers. Résultats : Nous avons réalisés 58 FAV chez 58 patients avec un suivi moyen de 30 jours. La thrombose et non maturation a été observée chez 8 patients (14%) et 4 patients (7%) respectivement. La valeur de débit peropératoire des fistules sans échec précoce était significativement plus élevée que dans les fistules avec échec précoce (230 v. 98 mL/min ; Ρ = 0.007), tout comme à une semaine (753 vs 228 mL/min ; P=0.0008) et 4 semaines (915 vs 245 mL/min, P<0.0001j. La mesure du débit avec une valeur seuil à 120 mL/min présente une sensibilité de 67%, une spécificité de 75% et une valeur prédictive positive de 91%. Conclusions : Un débit sanguin < 120mL/min a une bonne valeur prédictive positive d'échec précoce dans les FAV. Durant la procédure, cette valeur seuil, doit être utilisée pour sélectionner de manière appropriée les FAV nécessitant durant la même intervention une correction immédiate afin d'améliorer le débit. Une étude consécutive devra investiguer les origines des débits faibles des FAV objectivés durant leur confection.