8 resultados para pumping system design
em Université de Lausanne, Switzerland
Resumo:
While mobile technologies can provide great personalized services for mobile users, they also threaten their privacy. Such personalization-privacy paradox are particularly salient for context aware technology based mobile applications where user's behaviors, movement and habits can be associated with a consumer's personal identity. In this thesis, I studied the privacy issues in the mobile context, particularly focus on an adaptive privacy management system design for context-aware mobile devices, and explore the role of personalization and control over user's personal data. This allowed me to make multiple contributions, both theoretical and practical. In the theoretical world, I propose and prototype an adaptive Single-Sign On solution that use user's context information to protect user's private information for smartphone. To validate this solution, I first proved that user's context is a unique user identifier and context awareness technology can increase user's perceived ease of use of the system and service provider's authentication security. I then followed a design science research paradigm and implemented this solution into a mobile application called "Privacy Manager". I evaluated the utility by several focus group interviews, and overall the proposed solution fulfilled the expected function and users expressed their intentions to use this application. To better understand the personalization-privacy paradox, I built on the theoretical foundations of privacy calculus and technology acceptance model to conceptualize the theory of users' mobile privacy management. I also examined the role of personalization and control ability on my model and how these two elements interact with privacy calculus and mobile technology model. In the practical realm, this thesis contributes to the understanding of the tradeoff between the benefit of personalized services and user's privacy concerns it may cause. By pointing out new opportunities to rethink how user's context information can protect private data, it also suggests new elements for privacy related business models.
Resumo:
Background: Burnout syndrome (BS) is increasing among health professionals, including family doctors (FD). Aim: To characterize the prevalence of BS in a sample of FDs working in the Portuguese National Health System. Design: Cross-sectional survey. Setting: Primary Health Care Centers (HCC) from the 18 continental districts and 2 archipelagos of Portugal. Method: The Portuguese version of the Maslach Burnout Inventory - Human Services Survey (MBI - HSS) was sent to 40 randomly selected health-care centers (HCC) and distributed to the FDs employed. Sociodemographic and work-related data was also collected. Participants were classified as having high, average or low levels of emotional exhaustion (EE), depersonalization (DP) and personal accomplishment (PA) dimensions of burnout. Results: 371 questionnaires were sent, of which 153 (83 women, age range 29-64 years; response rate 41%) returned. One quarter (25.5%) of participants had high EE, 10.1% high DP and 11.4% high PA, but only 2.0% of participants scored high for all three dimensions. Women had significantly higher DP and PA scores than men; increased daily workload also led to increased PA scores. Conversely, no association was found between BS scores and age, marital status, number of years of practice or type of HCC (Family or Personalized). Conclusion: High burnout is relatively common among Portuguese family doctors, yet slightly lower than reported for other European countries. Burnout relief measures should be developed in order to prevent a further increase of BS among Portuguese FDs.
Resumo:
AIM: To characterise the prevalence of burnout syndrome in a sample of family doctors (FDs) working in the Portuguese National Health System. DESIGN: Cross-sectional survey. SETTING: Primary healthcare centres from the 18 continental districts and two archipelagos of Portugal. METHOD: The Portuguese version of the Maslach Burnout Inventory-Human Services Survey was sent to 40 randomly selected healthcare centres and distributed to the FDs employed. Socio-demographic and work-related data were also collected. Participants were classified as having high, average or low levels of emotional exhaustion (EE), depersonalisation (DP) and personal accomplishment (PA) dimensions of burnout. RESULTS: 371 questionnaires were sent, of which 153 (83 women, age range 29-64 years; response rate 41%) returned. One-quarter (25.3%, 95% CI 18.6% to 33.1%) of FDs scored high for EE, 16.2% (10.7% to 23.2%) for DP and 16.7% (11.1% to 23.6%) for lack of PA. On multivariate analysis, being married, of older age, having many years of practice or working in a personalised healthcare unit tended to be associated with increased burnout components. Men tended to present higher EE and DP but lower lack of PA than women. Finally, the prevalence (95% CI) of burnout ranged between 4.1% (1.5% to 8.6%) and 32.4% (25.0% to 40.6%), depending on the definition used. CONCLUSIONS: High burnout is relatively common among Portuguese FDs. Burnout relief measures should be developed in order to prevent a further increase of burnout syndrome among Portuguese FDs.
Resumo:
BACKGROUND: Previous published studies have shown significant variations in colonoscopy performance, even when medical factors are taken into account. This study aimed to examine the role of nonmedical factors (ie, embodied in health care system design) as possible contributors to variations in colonoscopy performance. METHODS: Patient data from a multicenter observational study conducted between 2000 and 2002 in 21 centers in 11 western countries were used. Variability was captured through 2 performance outcomes (diagnostic yield and colonoscopy withdrawal time), jointly studied as dependent variables, using a multilevel 2-equation system. RESULTS: Results showed that open-access systems and high-volume colonoscopy centers were independently associated with a higher likelihood of detecting significant lesions and longer withdrawal durations. Fee for service (FFS) payment was associated with shorter withdrawal durations, and so had an indirect negative impact on the diagnostic yield. Teaching centers exhibited lower detection rates and longer withdrawal times. CONCLUSIONS: Our results suggest that gatekeeping colonoscopy is likely to miss patients with significant lesions and that developing specialized colonoscopy units is important to improve performance. Results also suggest that FFS may result in a lower quality of care in colonoscopy practice and highlight the fact that longer withdrawal times do not necessarily indicate higher quality in teaching centers.
Resumo:
Cataract surgery is often performed in patients suffering from associated pathologies. Our goal is to develop a biodegradable drug delivery system (DDS) combined with the artificial intraocular lens (IOL). DDS were manufactured using poly(D,L-lactide-co-glycolide), or PLGA, and were loaded with triamcinolone acetonide (TA). The loading capacity was approximately 1050 microg of TA per DDS. The higher the molecular weight of PLGA (34,000, 48,000 and 80,000Da), the slower was the release of TA in vitro. Cataract surgery was performed on the right eye of rabbits. IOL was inserted with (i) no DDS, (ii) unloaded DDS PLGA48000, (iii) one loaded DDS PLGA48000, (iv) two loaded DDS. The number of inflammatory cells and the protein concentration were measured in the aqueous humor (AH). Unloaded DDS showed good ocular biocompatibility. One DDS PLGA48000 loaded with TA significantly reduced postoperative ocular inflammation. Two loaded DDS PLGA48000 was even more effective in inhibiting such inflammation. On long-term observation (days 63 and 84), reduction of inflammation could be obtained by insertion of one DDS PLGA48000 and a second DDS PLGA80000. Therefore, our "all in one" system is very promising since it could replace oral treatment and reduce the number of intraocular injections
Resumo:
Immunotherapy is defined as the treatment of disease by inducing, enhancing, or suppressing an immune response, whereas preventive vaccination is intended to prevent the development of diseases in healthy subjects. Most successful prophylactic vaccines rely on the induction of high titers of neutralizing antibodies. It is generally thought that therapeutic vaccination requires induction of robust T-cell mediated immunity. The diverse array of potential or already in use immunotherapeutic and preventive agents all share the commonality of stimulating the immune system. Hence, measuring those vaccination-induced immune responses gives the earliest indication of vaccine take and its immune modulating effects.
Resumo:
Whether a higher dose of a long-acting angiotensin II receptor blocker (ARB) can provide as much blockade of the renin-angiotensin system over a 24-hour period as the combination of an angiotensin-converting enzyme inhibitor and a lower dose of ARB has not been formally demonstrated so far. In this randomized double-blind study we investigated renin-angiotensin system blockade obtained with 3 doses of olmesartan medoxomil (20, 40, and 80 mg every day) in 30 normal subjects and compared it with that obtained with lisinopril alone (20 mg every day) or combined with olmesartan medoxomil (20 or 40 mg). Each subject received 2 dose regimens for 1 week according to a crossover design with a 1-week washout period between doses. The primary endpoint was the degree of blockade of the systolic blood pressure response to angiotensin I 24 hours after the last dose after 1 week of administration. At trough, the systolic blood pressure response to exogenous angiotensin I was 58% +/- 19% with 20 mg lisinopril (mean +/- SD), 58% +/- 11% with 20 mg olmesartan medoxomil, 62% +/- 16% with 40 mg olmesartan medoxomil, and 76% +/- 12% with the highest dose of olmesartan medoxomil (80 mg) (P = .016 versus 20 mg lisinopril and P = .0015 versus 20 mg olmesartan medoxomil). With the combinations, blockade was 80% +/- 22% with 20 mg lisinopril plus 20 mg olmesartan medoxomil and 83% +/- 9% with 20 mg lisinopril plus 40 mg olmesartan medoxomil (P = .3 versus 80 mg olmesartan medoxomil alone). These data demonstrate that a higher dose of the long-acting ARB olmesartan medoxomil can produce an almost complete 24-hour blockade of the blood pressure response to exogenous angiotensin in normal subjects. Hence, a higher dose of a long-acting ARB is as effective as a lower dose of the same compound combined with an angiotensin-converting enzyme inhibitor in terms of blockade of the vascular effects of angiotensin.