93 resultados para pulse amperometric detection
em Université de Lausanne, Switzerland
Resumo:
Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.
Resumo:
We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.
Resumo:
Stable isotope labels are routinely introduced into proteomes for quantification purposes. Full labeling of cells in varying biological states, followed by sample mixing, fractionation and intensive data acquisition, is used to obtain accurate large-scale quantification of total protein levels. However, biological processes often affect only a small group of proteins for a short time, resulting in changes that are difficult to detect against the total proteome background. An alternative approach could be the targeted analysis of the proteins synthesized in response to a given biological stimulus. Such proteins can be pulse-labeled with a stable isotope by metabolic incorporation of 'heavy' amino acids. In this study we investigated the specific detection and identification of labeled proteins using acquisition methods based on Precursor Ion Scans (PIS) on a triple-quadrupole ion trap mass spectrometer. PIS-based methods were set to detect unique immonium ions originating from labeled peptides. Different labels and methods were tested in standard mixtures to optimize performance. We showed that, in comparison with an untargeted analysis on the same instrument, the approach allowed a several-fold increase in the specificity of detection of labeled proteins over unlabeled ones. The technique was applied to the identification of proteins secreted by human cells into growth media containing bovine serum proteins, allowing the preferential detection of labeled cellular proteins over unlabeled bovine ones. However, compared with untargeted acquisitions on two different instruments, the PIS-based strategy showed some limitations in sensitivity. We discuss possible perspectives of the technique.
Resumo:
Blood pressure (BP) is a heritable, quantitative trait with intraindividual variability and susceptibility to measurement error. Genetic studies of BP generally use single-visit measurements and thus cannot remove variability occurring over months or years. We leveraged the idea that averaging BP measured across time would improve phenotypic accuracy and thereby increase statistical power to detect genetic associations. We studied systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and pulse pressure (PP) averaged over multiple years in 46,629 individuals of European ancestry. We identified 39 trait-variant associations across 19 independent loci (p < 5 × 10(-8)); five associations (in four loci) uniquely identified by our LTA analyses included those of SBP and MAP at 2p23 (rs1275988, near KCNK3), DBP at 2q11.2 (rs7599598, in FER1L5), and PP at 6p21 (rs10948071, near CRIP3) and 7p13 (rs2949837, near IGFBP3). Replication analyses conducted in cohorts with single-visit BP data showed positive replication of associations and a nominal association (p < 0.05). We estimated a 20% gain in statistical power with long-term average (LTA) as compared to single-visit BP association studies. Using LTA analysis, we identified genetic loci influencing BP. LTA might be one way of increasing the power of genetic associations for continuous traits in extant samples for other phenotypes that are measured serially over time.
Resumo:
We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.
Resumo:
The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.
Resumo:
Résumé : Les progrès techniques de la spectrométrie de masse (MS) ont contribué au récent développement de la protéomique. Cette technique peut actuellement détecter, identifier et quantifier des milliers de protéines. Toutefois, elle n'est pas encore assez puissante pour fournir une analyse complète des modifications du protéome corrélées à des phénomènes biologiques. Notre objectif était le développement d'une nouvelle stratégie pour la détection spécifique et la quantification des variations du protéome, basée sur la mesure de la synthèse des protéines plutôt que sur celle de la quantité de protéines totale. Pour cela, nous volions associer le marquage pulsé des protéines par des isotopes stables avec une méthode d'acquisition MS basée sur le balayage des ions précurseurs (precursor ion scan, ou PIS), afin de détecter spécifiquement les protéines ayant intégré les isotopes et d'estimer leur abondance par rapport aux protéines non marquées. Une telle approche peut identifier les protéines avec les plus hauts taux de synthèse dans une période de temps donnée, y compris les protéines dont l'expression augmente spécifiquement suite à un événement précis. Nous avons tout d'abord testé différents acides aminés marqués en combinaison avec des méthodes PIS spécifiques. Ces essais ont permis la détection spécifique des protéines marquées. Cependant, en raison des limitations instrumentales du spectromètre de masse utilisé pour les méthodes PIS, la sensibilité de cette approche s'est révélée être inférieure à une analyse non ciblée réalisée sur un instrument plus récent (Chapitre 2.1). Toutefois, pour l'analyse différentielle de deux milieux de culture conditionnés par des cellules cancéreuses humaines, nous avons utilisé le marquage métabolique pour distinguer les protéines d'origine cellulaire des protéines non marquées du sérum présentes dans les milieux de culture (Chapitre 2.2). Parallèlement, nous avons développé une nouvelle méthode de quantification nommée IBIS, qui utilise des paires d'isotopes stables d'acides aminés capables de produire des ions spécifiques qui peuvent être utilisés pour la quantification relative. La méthode IBIS a été appliquée à l'analyse de deux lignées cellulaires cancéreuses complètement marquées, mais de manière différenciée, par des paires d'acides aminés (Chapitre 2.3). Ensuite, conformément à l'objectif initial de cette thèse, nous avons utilisé une variante pulsée de l'IBIS pour détecter des modifications du protéome dans des cellules HeLa infectée par le virus humain Herpes Simplex-1 (Chapitre 2.4). Ce virus réprime la synthèse des protéines des cellules hôtes afin d'exploiter leur mécanisme de traduction pour la production massive de virions. Comme prévu, de hauts taux de synthèse ont été mesurés pour les protéines virales détectées, attestant de leur haut niveau d'expression. Nous avons de plus identifié un certain nombre de protéines humaines dont le rapport de synthèse et de dégradation (S/D) a été modifié par l'infection virale, ce qui peut donner des indications sur les stratégies utilisées par les virus pour détourner la machinerie cellulaire. En conclusion, nous avons montré dans ce travail que le marquage métabolique peut être employé de façon non conventionnelle pour étudier des dimensions peu explorées en protéomique. Summary : In recent years major technical advancements greatly supported the development of mass spectrometry (MS)-based proteomics. Currently, this technique can efficiently detect, identify and quantify thousands of proteins. However, it is not yet sufficiently powerful to provide a comprehensive analysis of the proteome changes correlated with biological phenomena. The aim of our project was the development of ~a new strategy for the specific detection and quantification of proteomé variations based on measurements of protein synthesis rather than total protein amounts. The rationale for this approach was that changes in protein synthesis more closely reflect dynamic cellular responses than changes in total protein concentrations. Our starting idea was to couple "pulsed" stable-isotope labeling of proteins with a specific MS acquisition method based on precursor ion scan (PIS), to specifically detect proteins that incorporated the label and to simultaneously estimate their abundance, relative to the unlabeled protein isoform. Such approach could highlight proteins with the highest synthesis rate in a given time frame, including proteins specifically up-regulated by a given biological stimulus. As a first step, we tested different isotope-labeled amino acids in combination with dedicated PIS methods and showed that this leads to specific detection of labeled proteins. Sensitivity, however, turned out to be lower than an untargeted analysis run on a more recent instrument, due to MS hardware limitations (Chapter 2.1). We next used metabolic labeling to distinguish the proteins of cellular origin from a high background of unlabeled (serum) proteins, for the differential analysis of two serum-containing culture media conditioned by labeled human cancer cells (Chapter 2.2). As a parallel project we developed a new quantification method (named ISIS), which uses pairs of stable-isotope labeled amino acids able to produce specific reporter ions, which can be used for relative quantification. The ISIS method was applied to the analysis of two fully, yet differentially labeled cancer cell lines, as described in Chapter 2.3. Next, in line with the original purpose of this thesis, we used a "pulsed" variant of ISIS to detect proteome changes in HeLa cells after the infection with human Herpes Simplex Virus-1 (Chapter 2.4). This virus is known to repress the synthesis of host cell proteins to exploit the translation machinery for the massive production of virions. As expected, high synthesis rates were measured for the detected viral proteins, confirming their up-regulation. Moreover, we identified a number of human proteins whose synthesis/degradation ratio (S/D) was affected by the viral infection and which could provide clues on the strategies used by the virus to hijack the cellular machinery. Overall, in this work, we showed that metabolic labeling can be employed in alternative ways to investigate poorly explored dimensions in proteomics.
Resumo:
Raman spectroscopy has been applied to characterize fiber dyes and determine the discriminating ability of the method. Black, blue, and red acrylic, cotton, and wool samples were analyzed. Four excitation sources were used to obtain complementary responses in the case of fluorescent samples. Fibers that did not provide informative spectra using a given laser were usually detected using another wavelength. For any colored acrylic, the 633-nm laser did not provide Raman information. The 514-nm laser provided the highest discrimination for blue and black cotton, but half of the blue cottons produced noninformative spectra. The 830-nm laser exhibited the highest discrimination for red cotton. Both visible lasers provided the highest discrimination for black and blue wool, and NIR lasers produced remarkable separation for red and black wool. This study shows that the discriminating ability of Raman spectroscopy depends on the fiber type, color, and the laser wavelength.
Resumo:
Glutamate and the N-methyl-D-aspartate receptor ligand D-serine are putative gliotransmitters. Here, we show by immunogold cytochemistry of the adult hippocampus that glutamate and D-serine accumulate in synaptic-like microvesicles (SLMVs) in the perisynaptic processes of astrocytes. The estimated concentration of fixed glutamate in the astrocytic SLMVs is comparable to that in synaptic vesicles of excitatory nerve terminals (∼45 and ∼55 mM, respectively), whereas the D-serine level is about 6 mM. The vesicles are organized in small spaced clusters located near the astrocytic plasma membrane. Endoplasmic reticulum is regularly found in close vicinity to SLMVs, suggesting that astrocytes contain functional nanodomains, where a local Ca(2+) increase can trigger release of glutamate and/or D-serine.
Resumo:
BACKGROUND: Early detection and treatment of colorectal adenomatous polyps (AP) and colorectal cancer (CRC) is associated with decreased mortality for CRC. However, accurate, non-invasive and compliant tests to screen for AP and early stages of CRC are not yet available. A blood-based screening test is highly attractive due to limited invasiveness and high acceptance rate among patients. AIM: To demonstrate whether gene expression signatures in the peripheral blood mononuclear cells (PBMC) were able to detect the presence of AP and early stages CRC. METHODS: A total of 85 PBMC samples derived from colonoscopy-verified subjects without lesion (controls) (n = 41), with AP (n = 21) or with CRC (n = 23) were used as training sets. A 42-gene panel for CRC and AP discrimination, including genes identified by Digital Gene Expression-tag profiling of PBMC, and genes previously characterised and reported in the literature, was validated on the training set by qPCR. Logistic regression analysis followed by bootstrap validation determined CRC- and AP-specific classifiers, which discriminate patients with CRC and AP from controls. RESULTS: The CRC and AP classifiers were able to detect CRC with a sensitivity of 78% and AP with a sensitivity of 46% respectively. Both classifiers had a specificity of 92% with very low false-positive detection when applied on subjects with inflammatory bowel disease (n = 23) or tumours other than CRC (n = 14). CONCLUSION: This pilot study demonstrates the potential of developing a minimally invasive, accurate test to screen patients at average risk for colorectal cancer, based on gene expression analysis of peripheral blood mononuclear cells obtained from a simple blood sample.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
Cancer is a major burden in today's society and one of the leading causes of death in industrialised countries. Various avenues for the detection of cancer exist, most of which rely on standard methods, such as histology, ELISA, and PCR. Here we put the focus on nanomechanical biosensors derived from atomic force microscopy cantilevers. The versatility of this novel technology has been demonstrated in different applications and in some ways surpasses current technologies, such as microarray, quartz crystal microbalance and surface plasmon resonance. The technology enables label free biomarker detection without the necessity of target amplification in a total cellular background, such as BRAF mutation analysis in malignant melanoma. A unique application of the cantilever array format is the analysis of conformational dynamics of membrane proteins associated to surface stress changes. Another development is characterisation of exhaled breath which allows assessment of a patient's condition in a non-invasive manner.
Resumo:
Fifty-three patients with histologically proven carcinoma were injected with highly purified [131I]-labeled goat antibodies or fragments of antibodies against carcinoembryonic antigen (CEA). Each patient was tested by external photoscanning 4, 24, 36 and 48 h after injection. In 22 patients (16 of 38 injected with intact antibodies, 5 of 13 with F(ab')2 fragments and 1 of 2 with Fab' fragments), an increased concentration of 131I radioactivity corresponding to the previously known tumor location was detected by photoscanning 36-48 h after injection. Blood pool and secreted radioactivity was determined in all patients by injecting 15 min before scanning, [99mTc]-labeled normal serum albumin and free 99mTc04-. The computerized subtraction of 99mTc from 131I radioactivity enhanced the definition of tumor localization in the 22 positive patients. However, in spite of the computerized subtraction, interpretation of the scans remained doubtful for 12 patients and was entirely negative for 19 additional patients. In order to provide a more objective evaluation for the specificity of the tumor localization of antibodies, 14 patients scheduled for tumor resection were injected simultaneously with [131I]-labeled antibodies or fragments and with [125I]-labeled normal goat IgG or fragments. After surgery, the radioactivity of the two isotopes present either in tumor or adjacent normal tissues was measured in a dual channel scintillation counter. The results showed that the antibodies or their fragments were 2-4 times more concentrated in the tumor than in the normal tissues. In addition, it was shown that the injected antibodies formed immune complexes with circulating CEA and that the amount of immune complexes detectable in serum was roughly proportional to the level of circulating CEA.
Resumo:
BACKGROUND: Capsular fibrosis is a severe complication after breast implantation with an uncertain etiology. Microbial colonization of the prosthesis is hypothesized as a possible reason for the low-grade infection and subsequent capsular fibrosis. Current diagnostic tests consist of intraoperative swabs and tissue biopsies. Sonication of removed implants may improve the diagnosis of implant infection by detachment of biofilms from the implant surface. METHODS: Breast implants removed from patients with Baker grades 3 and 4 capsular contracture were analyzed by sonication, and the resulting sonication fluid was quantitatively cultured. RESULTS: This study investigated 22 breast implants (6 implants with Baker 3 and 16 implants with Baker 4 capsular fibrosis) from 13 patients. The mean age of the patients was 49 years (range, 31-76 years). The mean implant indwelling time was 10.4 years (range, 3 months to 30 years). Of the 22 implants, 12 were used for breast reconstruction and 10 for aesthetic procedures. The implants were located subglandularly (n = 12), submuscularly (n = 6), and subcutaneously (n = 4). Coagulase-negative staphylococci, Propionibacterium acnes, or both were detected in the sonication fluid cultures of nine implants (41%), eight of which grew significant numbers of microorganisms (>100 colonies/ml of sonication fluid). CONCLUSIONS: Sonication detected bacteria in 41% of removed breast implants. The identified bacteria belonged to normal skin flora. Further investigation is needed to determine any causal relation between biofilms and capsular fibrosis.