6 resultados para proof of knowledge

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction. Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. Aim. To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. Materials and methods. A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. Results. Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. Conclusions. Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Healthcare professionals regularly read the summary of product characteristics (SmPC) as one of the various sources of information on the risks of drug use in women of childbearing age and during pregnancy. The aim of this article is to present an overview of the teratogenic potential of various antiepileptic drugs and to compare these data with the information provided by the SmPCs. METHODS: A literature search on the teratogenic risks of 19 antiepileptic agents was conducted and the results were compared with the information on the use in women of childbearing age and during pregnancy provided by the SmPCs of 38 commercial products available in Switzerland and Germany. RESULTS: The teratogenic risk is discussed in all available SmPCs. Quantification of the risk for birth defects and the numbers of documented pregnancies are mostly missing. Reproductive safety information in SmPCs showed poor concordance with risk levels reported in the literature. Recommendations concerning the need to monitor plasma levels and possibly perform dose adjustments during pregnancy to prevent treatment failure were missing in five Swiss and two German SmPCs. DISCUSSION: The information regarding use in women of childbearing age and during pregnancy provided by the SmPCs is heterogeneous and poorly reflects the current state of knowledge. Regular updates of SmPCs are warranted in order for these documents to be of reliable use for health care professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A national survey conducted in Switzerland aimed to evaluate the knowledge of physiotherapists regarding the legal requirements for record keeping and to collect their feedback about record keeping in general. Three physiotherapists from various professional practice groups and a lawyer specialised in health law developed a questionnaire that was sent to the 7,753 members of two existing national associations of physiotherapists. The questionnaire evaluated the participants' knowledge by calculating a score of legal knowledge, which had a maximum of 30 points. We included 825 questionnaires in the analysis. The large majority (83.4%) of participants confessed an ignorance of the legal requirements concerning record keeping prior to the survey. The average score of legal compatibility was 8 points. The younger age of the physiotherapists was a significant predictor of having knowledge of the legal requirements for record keeping (p <0.001). The participants had an appreciation of the value of records, but they did not have the relevant knowledge regarding the legal requirements for keeping records. The participants blamed a lack of time and remuneration for their failure to keep records according to known requirements. All practising allied health professionals should keep up-to-date and accurate records that conform to active legal requirements and existing international guidelines. In addition to the existing legal requirements, the emergence of e-health and the electronic era will trigger major changes in patient record management by physiotherapists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.