58 resultados para portable extractor
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: Screening for obstructive sleep apnea (OSA) is recommended as part of the preoperative assessment of obese patients scheduled for bariatric surgery. The objective of this study was to compare the sensitivity of oximetry alone versus portable polygraphy in the preoperative screening for OSA. METHODS: Polygraphy (type III portable monitor) and oximetry data recorded as part of the preoperative assessment before bariatric surgery from 68 consecutive patients were reviewed. We compared the sensitivity of 3% or 4% desaturation index (oximetry alone) with the apnea-hypopnea index (AHI; polygraphy) to diagnose OSA and classify the patients as normal (<10 events per hour), mild to moderate (10-30 events per hour), or severe (>30 events per hour). RESULTS: Using AHI, the prevalence of OSA (AHI > 10 per hour) was 57.4%: 16.2% of the patients were classified as severe, 41.2% as mild to moderate, and 42.6% as normal. Using 3% desaturation index, 22.1% were classified as severe, 47.1% as mild to moderate, and 30.9% as normal. With 4% desaturation index, 17.6% were classified as severe, 32.4% as mild, and 50% as normal. Overall, 3% desaturation index compared to AHI yielded a 95% negative predictive value to rule out OSA (AHI > 10 per hour) and a 100% sensitivity (0.73 positive predictive value) to detect severe OSA (AHI > 30 per hour). CONCLUSIONS: Using oximetry with 3% desaturation index as a screening tool for OSA could allow us to rule out significant OSA in almost a third of the patients and to detect patients with severe OSA. This cheap and widely available technique could accelerate preoperative work-up of these patients.
Resumo:
Rapport de SynthèseIntroductionLa recherche des apnées du sommeil est recommandée dans la prise en charge préopératoire des patients obèses chez qui une chirurgie bariatrique est envisagée. Toutefois le type d'examen nécessaire pour la détection des apnées dans cette population reste encore discuté. L'objectif de cette étude était de comparer la sensibilité de l'oxymétrie par rapport à la polygraphie lors du screening préopératoire de l'apnée obstructive du sommeil.MéthodeNous avons analysé rétrospectivement les données d'enregistrement de la polygraphie (moniteur portable de type III) et de l'oxymétrie de 68 patients consécutifs adressés au Centre du sommeil dans le cadre de leur bilan avant chirurgie bariatrique.Nous avons comparé la sensibilité de l'index de désaturation 3% ou 4% (à partir de l'oxymétrie seule) avec l'index d'apnée-hypopnée (à partir de la polygraphie) pour diagnostiquer l'apnée obstructive du sommeil. Les patients ont été réparti en 3 groupes selon la sévérité de leur atteinte: normale (< 10 événements/heure), faible à moyenne (10-30 événements/heure), sévère (>30 événements/heure).RésultatsSi l'on considère l'index d'apnée-hypopnée (polygraphie), la prévalence de l'apnée obstructive du sommeil avec un index d'apnée-hypopnée supérieur à 10 événements par heure était de 57,4% : 16,2% des patients étaient classés comme sévèrement atteints, 41,2% comme faiblement à moyennement atteints et 42.6% comme normaux.Si l'on considère l'index de désaturation 3%, 22,1% des patients étaient classés commes sévères , 47,1% comme faiblement à moyennement atteints et 30,9% comme normaux.Avec un index de désaturation de 4%, 17,6% étaient classés comme sévères, 32,4 % comme faiblement à moyennement atteints et 50% comme normaux.En comparant l'index de désaturation 3% à l'index d'apnée-hypopnée (>10 événements/heure), nous avons obtenu une valeur prédictive négative de 95% pour exclure une apnée obstructive du sommeil et une sensibilité de 100% dans la détection des cas sévères d'apnées obstructives du sommeil (index apnée-hypopnée >30 événements/heure). Le coefficient de concordance entre l'index d'apnée-hypopnée et l'index de désaturation 3% était de 0,759 alors qu'il était de 0,856 entre l'index d'apnée-hypopnée et l'index de désaturation de 4%.
Resumo:
We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.
Resumo:
BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.
Resumo:
RATIONALE: Limited-channel portable monitors (PMs) are increasingly used as an alternative to polysomnography (PSG) for the diagnosis of obstructive sleep apnoea (OSA). However, recommendations for the scoring of PM recordings are still lacking. Pulse-wave amplitude (PWA) drops, considered as surrogates for EEG arousals, may increase the detection sensitivity for respiratory events in PM recordings. OBJECTIVES: To investigate the performance of four different hypopnoea scoring criteria, using 3% or 4% oxygen desaturation levels, including or not PWA drops as surrogates for EEG arousals, and to determine the impact of measured versus reported sleep time on OSA diagnosis. METHODS: Subjects drawn from a population-based cohort underwent a complete home PSG. The PSG recordings were scored using the 2012 American Academy of Sleep Medicine criteria to determine the apnoea-hypopnoea index (AHI). Recordings were then rescored using only parameters available on type 3 PM devices according to different hypopnoea criteria and patients-reported sleep duration to determine the 'portable monitor AHIs' (PM-AHIs). MAIN RESULTS: 312 subjects were included. Overall, PM-AHIs showed a good concordance with the PSG-based AHI although it tended to slightly underestimate it. The PM-AHI using 3% desaturation without PWA drops showed the best diagnostic accuracy for AHI thresholds of ≥5/h and ≥15/h (correctly classifying 94.55% and 93.27% of subjects, respectively, vs 80.13% and 87.50% with PWA drops). There was a significant but modest correlation between PWA drops and EEG arousals (r=0.20, p=0.0004). CONCLUSION: Interpretation of PM recordings using hypopnoea criteria which include 3% desaturation without PWA drops as EEG arousal surrogate showed the best diagnosis accuracy compared with full PSG.
Resumo:
Ambulatory blood pressure profiles were obtained with the portable semi-automatic blood pressure recorder Remler M2000 in groups of 20 adolescents, 20 young and 20 middle-aged adults and 20 elderly untreated patients, all considered by their physician to be hypertensive. It was found that adolescents who are hypertensive when seeing their physician are more often normotensive outside the physician's office than adult and elderly patients under similar conditions. The increased heart rate variability which was detected in adolescents was not associated with an enhanced blood pressure variability.
Resumo:
The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.
Resumo:
Introduction: Coordination is a strategy chosen by the central nervous system to control the movements and maintain stability during gait. Coordinated multi-joint movements require a complex interaction between nervous outputs, biomechanical constraints, and pro-prioception. Quantitatively understanding and modeling gait coordination still remain a challenge. Surgeons lack a way to model and appreciate the coordination of patients before and after surgery of the lower limbs. Patients alter their gait patterns and their kinematic synergies when they walk faster or slower than normal speed to maintain their stability and minimize the energy cost of locomotion. The goal of this study was to provide a dynamical system approach to quantitatively describe human gait coordination and apply it to patients before and after total knee arthroplasty. Methods: A new method of quantitative analysis of interjoint coordination during gait was designed, providing a general model to capture the whole dynamics and showing the kinematic synergies at various walking speeds. The proposed model imposed a relationship among lower limb joint angles (hips and knees) to parameterize the dynamics of locomotion of each individual. An integration of different analysis tools such as Harmonic analysis, Principal Component Analysis, and Artificial Neural Network helped overcome high-dimensionality, temporal dependence, and non-linear relationships of the gait patterns. Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects. Results: The new method provided coordination scores at various walking speeds, ranged between 0 and 10. It determined the overall coordination of the lower limbs as well as the contribution of each joint to the total coordination. The difference between the pre-operative and post-operative coordination values were correlated with the improvements of the subjective outcome scores. Although the study group was small, the results showed a new way to objectively quantify gait coordination of patients undergoing total knee arthroplasty, using only portable body-fixed sensors. Conclusion: A new method for objective gait coordination analysis has been developed with very encouraging results regarding the objective outcome of lower limb surgery.
Resumo:
PURPOSE: NovoTTF-100A is a portable device delivering low-intensity, intermediate frequency electric fields via non-invasive, transducer arrays. Tumour Treatment Fields (TTF), a completely new therapeutic modality in cancer treatment, physically interfere with cell division. METHODS: Phase III trial of chemotherapy-free treatment of NovoTTF (20-24h/day) versus active chemotherapy in the treatment of patients with recurrent glioblastoma. Primary end-point was improvement of overall survival. RESULTS: Patients (median age 54years (range 23-80), Karnofsky performance status 80% (range 50-100) were randomised to TTF alone (n=120) or active chemotherapy control (n=117). Number of prior treatments was two (range 1-6). Median survival was 6.6 versus 6.0months (hazard ratio 0.86 [95% CI 0.66-1.12]; p=0.27), 1-year survival rate was 20% and 20%, progression-free survival rate at 6months was 21.4% and 15.1% (p=0.13), respectively in TTF and active control patients. Responses were more common in the TTF arm (14% versus 9.6%, p=0.19). The TTF-related adverse events were mild (14%) to moderate (2%) skin rash beneath the transducer arrays. Severe adverse events occurred in 6% and 16% (p=0.022) of patients treated with TTF and chemotherapy, respectively. Quality of life analyses favoured TTF therapy in most domains. CONCLUSIONS: This is the first controlled trial evaluating an entirely novel cancer treatment modality delivering electric fields rather than chemotherapy. No improvement in overall survival was demonstrated, however efficacy and activity with this chemotherapy-free treatment device appears comparable to chemotherapy regimens that are commonly used for recurrent glioblastoma. Toxicity and quality of life clearly favoured TTF.
Resumo:
Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) controls laxity but does not enable restoration of strictly normal 3D kinematics. The purpose of this study was to compare the kinematics of the pathological knee with that of the healthy knee after ACL plasty. This study applied a new ambulatory system using miniature captors. Material and method: Five patients with an isolated injury of the ACL participated in this study. The patients were assessed after injury (T1), at five months (T2), and at 14 months (T3) after surgery. The assessment included laxity (KT-1000), the IKDC score and the Lysholm score. The 3D angles of the knees were measured when walking 30 m on flat ground using a system composed of to small inertia units (3D accelerometer and 3D gyroscope) and a portable recorder. Functional settings were optimised and validating to ensure easy precise measurement of the 3D angles. Symmetry of the two knees was quantified using a symmetry index (SI) (difference in amplitude normalised in relation to mean amplitude) and the correlation coefficient CC. Results: Clinical indicators improved during the follow-up (IKDC T1: 3C, 2C; T2: 5B; T3: 2A, 3B; subjective IKD: 53-95; Lysholm 67-96). Mean laxity improved from 8.6m to 2.5 mm. The gait analysis showed increased symmetry in terms of amplitude for flexion-extension (SI: −17% at T1, −1% at T2, 1% at T3), and an increase in symmetry in terms of the rotation signature (CC: 0.16 at T1, 0.99 at T2, 0.99 at T3). There was no trend to varus-valgus. Discussion: This study demonstrates the clinical application of the new ambulatory system for measuring 3D angles of the knee joint. Joint symmetry increased after ACL plasty but still showed some perturbation at 14 months. The results observed here are in agreement with the literature. Other patients and other types of gait are being analysed. Conclusion: This portable system allows gait analysis outside the laboratory, before and after ACL injury. It is very useful for follow-up after surgery.
Resumo:
Captopril, an inhibitor of angiotensin converting enzyme, was administered twice daily to 13 hypertensive patients for a mean period of 9 weeks. Continuous blood pressure control in the ambulatory patients was established with a portable blood pressure recorder. Notwithstanding, in eight patients with normal renal function, plasma converting enzyme was found to resume normal activity before administration of the morning dose of captopril. Only in 5 patients with impaired renal function did some blockade of plasma converting enzyme persist for more than 12 hours. Measured plasma converting enzyme activity seemed to reflect total conversion of angiotensin I, including conversion in the pulmonary vascular bed, since changes in its activity were closely paralled by changes in plasma aldosterone levels. Bradykinin accumulation seems unlikely when converting enzyme and thus, presumably, kininase II has resumed normal activity. Captopril administration does not seem to alter plasma epinephrine or norepinephrine levels. Blood pressure reduction in the face of normal angiotensin converting enzyme activity is probably due to hyporesponsiveness of the arterioles to pressor hormones, which may be due to specific renin-related and/or nonspecific effects of captopril.
Resumo:
PURPOSE: In this study, the authors compared the cardiorespiratory responses between the 30-15 Intermittent Ice Test (30-15(IIT)) and the 30-15 Intermittent Fitness Test (30-15(IFT)) in semiprofessional hockey players. METHODS: Ten players (age 24 ± 6 y) from a Swiss League B team performed the 30-15(IIT) and 30-15(IFT) in random order (13 ± 4 d between trials). Cardiorespiratory variables were measured with a portable gas analyzer. Ventilatory threshold (VT), respiratory-compensation point (RCP), and maximal speeds were measured for both tests. Peak blood lactate ([La(peak)]) was measured at 1 min postexercise. RESULTS: Compared with 30-15(IFT), 30-15(IIT) peak heart rate (HR(peak); mean ± SD 185 ± 7 vs 189 ± 10 beats/min, P = .02) and peak oxygen consumption (VO(2peak)); 60 ± 7 vs 62.7 ± 4 mL/min/kg, P = .02) were lower, whereas [La(peak)] was higher (10.9 ± 1 vs 8.6 ± 2 mmol/L, P < .01) for the 30-15(IIT). VT and RCP values during the 30-15(IIT) and 30-15(IFT) were similar for %HR(peak) (76.3% ± 5% vs 75.5% ± 3%, P = .53, and 90.6% ± 3% vs. 89.8% ± 3%, P = .45) and % VO(2peak) (62.3% ± 5% vs 64.2% ± 6%, P = .46, and 85.9% ± 5% vs 84.0% ± 7%, P = .33). VO(2peak ))(r = .93, P < .001), HR(peak) (r = .86, P = .001), and final velocities (r = .69, P = .029) were all largely to almost perfectly correlated. CONCLUSIONS: Despite slightly lower maximal cardiorespiratory responses than in the field-running version of the test, the on-ice 30-15(IIT) is of practical interest since it is a specific maximal test with a higher anaerobic component.
The European Respiratory Society spirometry tent: a unique form of screening for airway obstruction.
Resumo:
In order to raise public awareness of the importance of early detection of airway obstruction and to enable many people who had not been tested previously to have their lung function measured, the European Lung Foundation and the European Respiratory Society (ERS) organised a spirometry testing tent during the annual ERS Congresses in 2004-2009. Spirometry was performed during the ERS Congresses in volunteers; all participants answered a simple, brief questionnaire on their descriptive characteristics, smoking and asthma. Portable spirometers were freely provided by the manufacturer. Nurses and doctors from pulmonary departments of local hospitals/universities gave their service for free. Lower limit of normal (LLN) and Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for diagnosing and grading airway obstruction were used. Of 12,448 participants in six congress cities, 10,395 (83.5%) performed acceptable spirometry (mean age 51.0 ± 18.4 yrs; 25.5% smokers; 5.5% asthmatic). Airway obstruction was present in 12.4% of investigated subjects according to LLN criteria and 20.3% according to GOLD criteria. Through multinomial logistic regression analysis, age, smoking habits and asthma were significant risk factors for airway obstruction. Relative risk ratio and 95% confidence interval for LLN stage I, for example, was 2.9 (2.0-4.1) for the youngest age (≤ 19 yrs), 1.9 (1.2-3.0) for the oldest age (≥ 80 yrs), 2.4 (2.0-2.9) for current smokers and 2.8 (2.2-3.6) for reported asthma diagnosis. In addition to being a useful advocacy tool, the spirometry tent represents an unusual occasion for early detection of airway obstruction in large numbers of city residents with an important public health perspective.