175 resultados para polyester prosthesis
em Université de Lausanne, Switzerland
Resumo:
Introduction: Extraskeletal myxoid chondrosarcoma (EMC) is a rare soft tissue tumour with a high risk for local recurrence and metastases. While this entity is resistant to radio- or chemo-therapy, wide resection remains the treatment of choice. Case report: A 60 year old man presented to our service with a large mass in his right thigh, slowly evolving over the past 7 years. His main complaint was the volume of his thigh. Imaging showed a 23x13x14 cm tumour in the quadriceps, eroding the cortical bone and with potential contamination of the knee joint. The risk of a pathological fracture was estimated considerable. A CT-guided core-needle biopsy revealed a FNCLCC grade 2 EMC. A thoraco-abdominal CT scan showed multiple pulmonary metastases. Due to the palliative situation with a very slow disease progression, a wide extraarticular resection of the distal femur and reconstruction with a megaprosthesis were performed. Extensive skin necrosis necessitated three revision procedures for débridement and confection of a pediculated lateral gastrocnemius muscle flap. No complementary treatment was possible for the pulmonary metastases. At 18 months follow-up, he walked without crutches, was able to do his activities of daily living. He was painfree and highly satisfied with the result. During the follow-up, slow progression of the pulmonary metastases was noted, which remained asymptomatic. Conclusion: Extraskeletal myxoid chondrosarcoma is a rare soft tissue tumour, and wide excision remains the treatment of choice. Whenever possible, limb salvage should be proposed to preserve function and quality of life.
Resumo:
PURPOSE: Nonspecific inflammatory reactions characterized by local tenderness, fever, and flu-like discomfort have been seen in patients undergoing endoluminal graft placement in the abdominal aorta or the femoral arteries. We undertook a study to assess the clinical and laboratory parameters of this inflammation. METHODS: Ten patients with femoropopliteal artery (n = 9) or aortic (n = 1) lesions were treated with EndoPro System 1 stent-grafts made of nitinol alloy and covered with a polyester (Dacron) fabric. Eleven patients implanted with a bare nitinol stent served as the control group. RESULTS: In the stent-graft group, four patients showed clinical signs of acute inflammation manifested by fever and local tenderness. Three of these patients suffered thrombosis of the stent-grafts during the first month of follow-up. Plasma levels of interleukin-1 beta and interleukin-6 in all stent-graft patients were markedly increased 1 day after intervention (7.3 +/- 2.8 versus 90.2 +/- 34.1 pg/mL and 15.6 +/- 5.8 versus 175.5 +/- 66.3 pg/mL, respectively; p < 0.01). This was followed by an increase in fibrinogen (3.0 +/- 0.2 versus 5.0 +/- 0.2 g/L; p < 0.05) and C-reactive protein (14.6 +/- 3.3 versus 77.5 +/- 15.0 mg/L; p < 0.01) at 1 week. No direct correlation between the inflammatory markers and symptoms could be found. In vitro analysis showed that individual components of the stent-graft did not activate human neutrophils, whereas the intact stent-graft itself induced a marked neutrophil activation. CONCLUSIONS: The component of the self-expanding stent-graft responsible for the nonspecific inflammatory reaction was not identified in this study. It is likely that the stent-graft itself or some as yet unrecognized element of the device other than the Dacron fabric or metal alloy may be a potent in vivo inducer of cytokine reaction by neutrophils.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
Objective: The vascular access steal syndrome is a complication occurring in 1-6% after native arterio-venous (AV) fistulas, often due to huge diameter of the vein. This results in very high flow, which could also be responsible for cardiac overload. The aim of this study is to evaluate the efficiency of a new approach in the treatment of this pathology using open-pore external scaffolding prosthesis.Methods: This a retrospective review of all patients presenting symptomatic high flow after native AV fistula between January 2007 and December 2009 in 3 vascular centers. Pre-operative duplex exam confirmed the diagnosis of high flow. The operation consisted in preparation of the whole fistula, measurement of the flow and section on the venous side. The vein was wrapped with this 6 to 8 mm open-pore external scaffolding prosthesis (ProVena, BBraun, Germany) according to its diameter and to the flow and then sutured. Measurement of the flow was repeated. Patients were followed by duplex exam at 1 week and at 1, 3, 6 and 12 months. Procedural success was defined as complete implantation of the prosthesis and reduction of the flow. Primary outcomes were reduction of the flow and recovery of the symptoms and secondary endpoint was patency of the fistula.Results: During the study period, 14 patients, with a mean age of 65・8 years old, have been operated with this technique.There were 2 native forearmfistulas and 12 on the armwith a mean pre-operative flow of 2600 ml/min (1800-3800). The mode of presentation was pain in 6 patients, neurological disorders in 10 and necrosis in 4. Moreover, 3 patients had cardiac insufficiency due to high flow in the fistula. The procedure was technically successful in 100% of cases. Re-intervention was necessary in 2 patients due to hematoma. Recovery of the initial symptoms occurred in 13 patients (93%). The mean flow reduction was 1200 ml/min (600-2000). In 1 patient, a persistent steal syndrome despite flow reduction to 1400 ml/min resulted in fistula closure 2 months later. At a mean follow-up of 22 months (4-35), all remaining patients (13/14) presented a patent fistula without recurrence.Conclusion: This new approach seems to be safe and effective in the treatment of symptomatic high flow native AV fistulas by significantly reducing the flow and avoiding closure of the vascular access. Longer follow-up with more patients are necessary to evaluate the risk of recurrence.
Resumo:
BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.
Resumo:
INTRODUCTION: Reconstructions of the fronto-orbital area remain a challenge to the reconstructive surgeon, due to the functional and esthetic impact. OBSERVATION: The authors present a case of a complex fronto-orbital reconstruction with a PEEK (PolyEtherEtherKetone) implant, associated with a skin expansion. DISCUSSION: With a follow-up of over three years, the cosmetic result is excellent. The authors believe that this technique is reliable, fast with long-term good results.
Resumo:
Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.