12 resultados para piston sampler
em Université de Lausanne, Switzerland
Resumo:
An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.
Resumo:
The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.
Resumo:
The metasomatism observed in the oceanic and continental lithosphere is generally interpreted to represent a continuous differentiation process forming anhydrous and hydrous veins plus a cryptic enrichment in the surrounding peridotite. In order to constrain the mechanisms of vein formation and potentially clarify the nature and origin of the initial metasomatic agent, we performed a series of high-pressure experiments simulating the liquid line of descent of a basanitic magma differentiating within continental or mature oceanic lithosphere. This series of experiments has been conducted in an end-loaded piston cylinder apparatus starting from an initial hydrous ne-normative basanite at 1.5 GPa and temperature varying between 1,250 and 980°C. Near-pure fractional crystallization process was achieved in a stepwise manner in 30°C temperature steps and starting compositions corresponding to the liquid composition of the previous, higher-temperature glass composition. Liquids evolve progressively from basanite to peralkaline, aluminum-rich compositions without significant SiO2 variation. The resulting cumulates are characterized by an anhydrous clinopyroxene + olivine assemblage at high temperature (1,250-1,160°C), while at lower temperature (1,130-980°C), hydrous cumulates with dominantly amphibole + minor clinopyroxene, spinel, ilmenite, titanomagnetite and apatite (1,130-980°C) are formed. This new data set supports the interpretation that anhydrous and hydrous metasomatic veins could be produced during continuous differentiation processes of primary, hydrous alkaline magmas at high pressure. However, the comparison between the cumulates generated by the fractional crystallization from an initial ne-normative liquid or from hy-normative initial compositions (hawaiite or picrobasalt) indicates that for all hydrous liquids, the different phases formed upon differentiation are mostly similar even though the proportions of hydrous versus anhydrous minerals could vary significantly. This suggests that the formation of amphibole-bearing metasomatic veins observed in the lithospheric mantle could be linked to the differentiation of initial liquids ranging from ne-normative to hy-normative in composition. The present study does not resolve the question whether the metasomatism observed in lithospheric mantle is a precursor or a consequence of alkaline magmatism; however, it confirms that the percolation and differentiation of a liquid produced by a low degree of partial melting of a source similar or slightly more enriched than depleted MORB mantle could generate hydrous metasomatic veins interpreted as a potential source for alkaline magmatism by various authors.
Resumo:
Occupational exposures to wood dust have been associated with an elevated risk of sinonasal cancer (SNC). Wood dust is recognized as a human carcinogen but the specific cancer causative agent remains unknown. One possible explanation is a co-exposure to; wood dust and polycyclic aromatic hydrocarbons (PAHs). PAHs could be generated during incomplete combustion of wood due to heat created by use of power tools. To determine if PAHs are generated from wood during common wood working operations, PAH concentrations in wood dust samples collected in an experimental chamber operated under controlled conditions were analyzed. In addition, personal air samples from workers exposed to wood dust (n = 30) were collected. Wood dust was generated using three different power tools: vibrating sander, belt sander, and saw; and six wood materials: fir, Medium Density Fiberboard (MDF), beech, mahogany, oak and wood melamine. Monitoring of wood workers was carried out by means of personal sampler device during wood working operations. We measured 21 PAH concentrations in wood dust samples by capillary gas chromatography-ion trap mass spectrometry (GC-MS). Total PAH concentrations in wood dust varied greatly (0.24-7.95 ppm) with the lowest being in MDF dust and the highest in wood melamine dust. Personal PAH exposures were between 37.5-119.8 ng m(-3) during wood working operations. Our results suggest that PAH exposures are present during woodworking operations and hence could play a role in the mechanism of cancer induction related to wood dust exposure.
Resumo:
Background and Aims: To protect the population from environmental tobacco smoke (ETS) Switzerland introduced a nationwide rather heterogeneous smoking ban in May 2010. The exposure situation of non-smoking hospitality workers before and after implementation of the new law is being assessed in a prospective cohort study. Methods: Exposure to ETS was measured using a novel method developed by the Institute for Work and Health in Lausanne. It is a passive sampler called MoNIC (Monitor of NICotine). The nicotine of the ETS is fixed onto a filter and transformed into salt of not volatile nicotine. Subsequently the number of passively smoked cigarettes is calculated. Badges were placed at the workplace as well as distributed to the participants for personal measuring. Additionally a salivary sample was taken to determine nicotine concentration. Results: At baseline Spearman's correlation between workplace and personal badge was 0.47. The average cigarette equivalents per day at the workplace obtained by badge significantly dropped from 5.1 (95%- CI: 2.4 to 7.9) at baseline to 0.3 (0.2 to 0.4) at first follow-up (n=29) three months later (p<0.001). For personal badges the number of passively smoked cigarettes declined from 1.5 (2.7 to 0.4) per day to 0.5 (0.3 to 0.8) (n=16).Salivary nicotine concentration in a subset of 13 participants who had worked on the day prior to the examination was 2.63 ng/ml before and 1.53 ng/ml after the ban (p=0.04). Spearman's correlation of salivary nicotine was 0.56 with workplace badge and 0.79 with personal badge concentrations. Conclusions: Workplace measurements clearly reflect the smoking regulation in a venue. The MoNIC badge proves to be a sensitive measuring device to determine personal ETS exposure and it is a demonstrative measure for communication with lay audiences and study participants as the number of passively smoked cigarettes is an easily conceivable result.
Resumo:
Introduction et objectif: Lors d'essais cliniques, le pharmacien est responsable de la préparation et de la dispensation des médicaments à évaluer. Un article récent a toutefois montré que les aspects pharmaceutiques liés au contrôle de la dose administrée in fine étaient souvent mal contrôlés. Il peut exister une différence entre la dose nominale fournie par le certificat d'analyse du fabricant et la dose réellement administrée au sujet, biais qui se reporte en cascade sur l'estimation des paramètres pharmaco¬cinétiques (PK), comme la clairance ou le volume de distribution. Ce travail visait à évaluer les biais entachant la quantité de médicament réellement injectée (iv/sc) aux volontaires d'un essai clinique étudiant la PK et la relation dose-réponse d'un nouveau produit biotechnologique. Méthode: La dose de médicament administrée lors de l'essai clinique (D) a été calculée de la manière suivante: D = C ? V - pertes. La concentration du produit (C; titre nominal du fabricant) a été vérifiée par immuno-essai. Le volume de médicament injecté (V) a été déterminé pour chaque injection par pesée (n=72), en utilisant la masse de la seringue avant et après injection et la densité du produit. Enfin, une analyse in vitro a permis d'évaluer les pertes liées à l'adsorption du produit dans les lignes de perfusion et de choisir le dispositif adéquat in vivo. Résultats: La concentration du médicament s'est révélée proche du titre nominal (96 ± 7%), et a été utilisée comme référence. Le volume injecté était quant à lui entaché d'un biais systématique par rapport à la valeur théorique correspondant à 0.03 mL pour la dose minimale (i.e. 75% du volume à injecter à cette dose). Une analyse complémentaire a montré que cela s'expliquait par une réaspiration partielle de la solution médica-menteuse avant le retrait de la seringue après injection sc, due à l'élasticité du piston. En iv, le biais était par contre provoqué par une réaspiration du soluté de perfusion co-administré. Enfin, la mesure des quantités de médicament récupérées après injection dans le dispositif de perfusion a démontré des pertes minimales par adsorption. Discussion-conclusion: Cette étude confirme l'existence de biais inversement corrélés au volume et à la concentration du médicament administré, pouvant provoquer des erreurs importantes sur les paramètres PK. Ce problème est négligé ou insuffisamment considéré dans les protocoles de Phase I et nécessiterait une planification rigoureuse. Les procédures opératoires devraient attirer l'attention sur ce point crucial.
Resumo:
In arson cases, the collection and detection of traces of ignitable liquids on a suspect's hands can provide information to a forensic investigation. Police forces currently lack a simple, robust, efficient and reliable solution to perform this type of swabbing. In this article, we describe a study undertaken to develop a procedure for the collection of ignitable liquid residues on the hands of arson suspects. Sixteen different collection supports were considered and their applicability for the collection of gasoline traces present on hands and their subsequent analysis in a laboratory was evaluated. Background contamination, consisting of volatiles emanating from the collection supports, and collection efficiencies of the different sampling materials were assessed by passive headspace extraction with an activated charcoal strip (DFLEX device) followed by gas chromatography-mass spectrometry (GC-MS) analysis. After statistical treatment of the results, non-powdered latex gloves were retained as the most suitable method of sampling. On the basis of the obtained results, a prototype sampling kit was designed and tested. This kit is made of a three compartment multilayer bag enclosed in a sealed metal can and containing three pairs of non-powdered latex gloves: one to be worn by the sampler, one consisting of a blank sample and the last one to be worn by the person suspected to have been in contact with ignitable liquids. The design of the kit was developed to be efficient in preventing external and cross-contaminations.
Resumo:
BACKGROUND: In May 2010, Switzerland introduced a heterogeneous smoking ban in the hospitality sector. While the law leaves room for exceptions in some cantons, it is comprehensive in others. This longitudinal study uses different measurement methods to examine airborne nicotine levels in hospitality venues and the level of personal exposure of non-smoking hospitality workers before and after implementation of the law. METHODS: Personal exposure to second hand smoke (SHS) was measured by three different methods. We compared a passive sampler called MoNIC (Monitor of NICotine) badge, to salivary cotinine and nicotine concentration as well as questionnaire data. Badges allowed the number of passively smoked cigarettes to be estimated. They were placed at the venues as well as distributed to the participants for personal measurements. To assess personal exposure at work, a time-weighted average of the workplace badge measurements was calculated. RESULTS: Prior to the ban, smoke-exposed hospitality venues yielded a mean badge value of 4.48 (95%-CI: 3.7 to 5.25; n = 214) cigarette equivalents/day. At follow-up, measurements in venues that had implemented a smoking ban significantly declined to an average of 0.31 (0.17 to 0.45; n = 37) (p = 0.001). Personal badge measurements also significantly decreased from an average of 2.18 (1.31-3.05 n = 53) to 0.25 (0.13-0.36; n = 41) (p = 0.001). Spearman rank correlations between badge exposure measures and salivary measures were small to moderate (0.3 at maximum). CONCLUSIONS: Nicotine levels significantly decreased in all types of hospitality venues after implementation of the smoking ban. In-depth analyses demonstrated that a time-weighted average of the workplace badge measurements represented typical personal SHS exposure at work more reliably than personal exposure measures such as salivary cotinine and nicotine.
Resumo:
BACKGROUND: The estimation of demographic parameters from genetic data often requires the computation of likelihoods. However, the likelihood function is computationally intractable for many realistic evolutionary models, and the use of Bayesian inference has therefore been limited to very simple models. The situation changed recently with the advent of Approximate Bayesian Computation (ABC) algorithms allowing one to obtain parameter posterior distributions based on simulations not requiring likelihood computations. RESULTS: Here we present ABCtoolbox, a series of open source programs to perform Approximate Bayesian Computations (ABC). It implements various ABC algorithms including rejection sampling, MCMC without likelihood, a Particle-based sampler and ABC-GLM. ABCtoolbox is bundled with, but not limited to, a program that allows parameter inference in a population genetics context and the simultaneous use of different types of markers with different ploidy levels. In addition, ABCtoolbox can also interact with most simulation and summary statistics computation programs. The usability of the ABCtoolbox is demonstrated by inferring the evolutionary history of two evolutionary lineages of Microtus arvalis. Using nuclear microsatellites and mitochondrial sequence data in the same estimation procedure enabled us to infer sex-specific population sizes and migration rates and to find that males show smaller population sizes but much higher levels of migration than females. CONCLUSION: ABCtoolbox allows a user to perform all the necessary steps of a full ABC analysis, from parameter sampling from prior distributions, data simulations, computation of summary statistics, estimation of posterior distributions, model choice, validation of the estimation procedure, and visualization of the results.
Resumo:
A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 °C for 15 min, followed by extraction at 80 °C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.
Resumo:
Introduction et objectif: Lors d'essais cliniques, le pharmacien est responsable de la préparation et de la dispensation des médicaments à évaluer. Un article récent a toutefois montré que les aspects pharmaceutiques liés au contrôle de la dose administrée in fine étaient souvent mal contrôlés. Il peut exister une différence entre la dose nominale fournie par le certificat d'analyse du fabricant et la dose réellement administrée au sujet, biais qui se reporte en cascade sur l'estimation des paramètres pharmacocinétiques (PK), comme la clairance ou le volume de distribution. Ce travail visait à évaluer les biais entachant la quantité de médicament réellement injectée (iv/sc) aux volontaires d'un essai clinique étudiant la PK et la relation dose-réponse d'un nouveau produit biotechnologique. Méthode: La dose de médicament administrée lors de l'essai clinique (D) a été calculée de la manière suivante: D = C * V - pertes. La concentration du produit (C; titre nominal du fabricant) a été vérifiée par immuno-essai. Le volume de médicament injecté (V) a été déterminé pour chaque injection par pesée (n=72), en utilisant la masse de la seringue avant et après injection et la densité du produit. Enfin, une analyse in vitro a permis d'évaluer les pertes liées à l'adsorption du produit dans les lignes de perfusion et de choisir le dispositif adéquat in vivo. Résultats: La concentration du médicament s'est révélée proche du titre nominal (96 ± 7%), et a été utilisée comme référence. Le volume injecté était quant à lui entaché d'un biais systématique par rapport à la valeur théorique correspondant à 0.03 mL pour la dose minimale (i.e. 75% du volume à injecter à cette dose). Une analyse complémentaire a montré que cela s'expliquait par une réaspiration partielle de la solution médica-menteuse avant le retrait de la seringue après injection sc, due à l'élasticité du piston. En iv, le biais était par contre provoqué par une réaspiration du soluté de perfusion co-administré. Enfin, la mesure des quantités de médicament récupérées après injection dans le dispositif de perfusion a démontré des pertes minimales par adsorption. Discussion-conclusion: Cette étude confirme l'existence de biais inversement corrélés au volume et à la concentration du médicament administré, pouvant provoquer des erreurs importantes sur les paramètres PK. Ce problème est négligé ou insuffisamment considéré dans les protocoles de Phase I et nécessiterait une planification rigoureuse. Les procédures opératoires devraient attirer l'attention sur ce point crucial.
Resumo:
Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.