2 resultados para physical self-concept
em Université de Lausanne, Switzerland
Resumo:
Background : In the present article, we propose an alternative method for dealing with negative affectivity (NA) biases in research, while investigating the association between a deleterious psychosocial environment at work and poor mental health. First, we investigated how strong NA must be to cause an observed correlation between the independent and dependent variables. Second, we subjectively assessed whether NA can have a large enough impact on a large enough number of subjects to invalidate the observed correlations between dependent and independent variables.Methods : We simulated 10,000 populations of 300 subjects each, using the marginal distribution of workers in an actual population that had answered the Siegrist's questionnaire on effort and reward imbalance (ERI) and the General Health Questionnaire (GHQ).Results : The results of the present study suggested that simulated NA has a minimal effect on the mean scores for effort and reward. However, the correlations between the effort and reward imbalance (ERI) ratio and the GHQ score might be important, even in simulated populations with a limited NA.Conclusions : When investigating the relationship between the ERI ratio and the GHQ score, we suggest the following rules for the interpretation of the results: correlations with an explained variance of 5% and below should be considered with caution; correlations with an explained variance between 5% and 10% may result from NA, although this effect does not seem likely; and correlations with an explained variance of 10% and above are not likely to be the result of NA biases. [Authors]
Resumo:
OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.