7 resultados para personal escolar

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Past traumatic events have been associated with poorer clinical outcomes in people with bipolar disorder. However, the impact of these events in the early stages of the illness remains unclear. The aim of this study was to investigate whether prior traumatic events were related to poorer outcomes 12 months following a first episode of psychotic mania. METHODS: Traumatic events were retrospectively evaluated from patient files in a sample of 65 participants who had experienced first episode psychotic mania. Participants were aged between 15 and 28 years and were treated at a specialised early psychosis service. Clinical outcomes were measured by a variety of symptomatic and functioning scales at the 12-month time-point. RESULTS: Direct-personal traumatic experiences prior to the onset of psychotic mania were reported by 48% of the sample. Participants with past direct-personal trauma had significantly higher symptoms of mania (p=0.02), depression (p=0.03) and psychopathology (p=0.01) 12 months following their first episode compared to participants without past direct-personal trauma, with medium to large effects observed. After adjusting for baseline scores, differences in global functioning (as measured by the Global Assessment of Functioning scale) were non-significant (p=0.05); however, participants with past direct-personal trauma had significantly poorer social and occupational functioning (p=0.04) at the 12-month assessment with medium effect. CONCLUSIONS: Past direct-personal trauma may predict poorer symptomatic and functional outcomes after first episode psychotic mania. Limitations include that the findings represent individuals treated at a specialist early intervention centre for youth and the retrospective assessment of traumatic events may have been underestimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).