206 resultados para pediatric critical care

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Critical care is a working environment with frequent exposure to stressful events. High levels of psychological stress have been associated with increased prevalence of burnout. Psychological distress acts as a potent trigger of cortisol secretions. We attempted to objectify endocrine stress reactivity. DESIGN: Observational cohort study during two 12-day periods in successive years. SETTING: A tertiary multidisciplinary neonatal and pediatric intensive care unit (33 beds). SUBJECTS: One hundred and twelve nurses and 27 physicians (94% accrual rate). INTERVENTIONS AND MEASUREMENTS: Cortisol determined from salivary samples collected every 2 hrs and after stressful events. Participants recorded the subjective perception of stress with every sample. Endocrine reactions were defined as transient surges in cortisol of >50% and 2.5 nmol/L over the baseline. MAIN RESULTS: During 7,145 working hours, we observed 474 (12.5%) endocrine reactions from 3,781 samples. The mean cortisol increase amounted to 10.6 nmol/L (219%). The mean occurrence rate of endocrine reactions per subject and sample was 0.159 (range, 0-0.43). Although the mean raw cortisol levels were lower in experienced team members (>3 yrs of intensive care vs. <3 yrs, 4.1 vs. 4.95 nmol/L, p < .001), professional experience failed to attenuate the frequency and magnitude of endocrine reactions, except for the subgroup of nurses and physicians with >8 yrs of intensive care experience. A high proportion (71.3%) of endocrine reactions occurred without conscious perception of stress. Unawareness of stress was higher in intensive care nurses (75.1%) than in intermediate care nurses (51.8%, p < .01). CONCLUSIONS: Stress-related cortisol surges occur frequently in neonatal and pediatric critical care staff. Cortisol increases are independent of subjective stress perception. Professional experience does not abate the endocrine stress reactivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a review of different methods enabling the monitoring of cerebral function in neonatal and paediatric intensive care. EEG, evoked potentials, conventional radiological studies, computerized tomography, ultrasound, intracranial pressure measurements, nuclear magnetic resonance, Doppler ultrasound, radioisotope studies, angiography, infra-red spectral analysis and last, but not least, clinical examination produce information regarding the neurological state of the patient which must be critically analysed in order to ensure optimal management of the case. Unfortunately, and in spite of impressive progress in non-invasive monitoring of the cerebral function, we are still forced to make important medical and ethical decisions without precise information about the neurological state of our patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Minimizing unwarranted prescription of antibiotics remains an important objective. Because of the heterogeneity between units regarding patient mix and other characteristics, site-specific targets for reduction must be identified. Here we present a model to address the issue by means of an observational cohort study. SETTING: A tertiary, multidisciplinary, neonatal, and pediatric intensive care unit of a university teaching hospital. PATIENTS: All newborns and children present in the unit (n = 456) between September 1998 and March 1999. Reasons for admission included postoperative care after cardiac surgery, major neonatal or pediatric surgery, severe trauma, and medical conditions requiring critical care. METHODS: Daily recording of antibiotics given and of indications for initiation. After discontinuation, each treatment episode was assessed as to the presence or absence of infection. RESULTS: Of the 456 patients 258 (56.6%) received systemic antibiotics, amounting to 1815 exposure days (54.6%) during 3322 hospitalization days. Of these, 512 (28%) were prescribed as prophylaxis and 1303 for suspected infection. Treatment for suspected ventilator-associated pneumonia accounted for 616 (47%) of 1303 treatment days and suspected sepsis for 255 days (20%). Patients were classified as having no infection or viral infection during 552 (40%) treatment days. The average weekly exposure rate in the unit varied considerably during the 29-week study period (range: 40-77/100 hospitalization days). Patient characteristics did not explain this variation. CONCLUSION: In this unit the largest reduction in antibiotic treatment would result from measures assisting suspected ventilator-associated pneumonia to be ruled out and from curtailing extended prophylaxis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Although endogenous nitric oxide (NO) is an excitatory mediator in the central nervous system, inhaled NO is not considered to cause neurologic side effects because of its short half-life. This study was motivated by a recent case report about neurologic symptoms and our own observation of severe electroencephalogram (EEG) abnormalities during NO inhalation. DESIGN: Blind, retrospective analyses of EEGs which were registered before, during, and after NO inhalation. EEG was classified in a 5-point rating system by an independent electroencephalographer who was blinded to the patients' clinical histories. Comparisons were made with the previous evaluation documented at recording. Other EEG-influencing parameters such as oxygen saturation, hemodynamics, electrolytes, and pH were evaluated. SETTING: Pediatric intensive care unit of a tertiary care university children's hospital. PATIENTS: Eleven ventilated, long-term paralyzed, sedated children (1 mo to 14 yrs) who had EEG or clinical assessment before NO treatment and EEG during NO inhalation. They were divided into two groups according to the NO-indication (e.g., congenital heart defect, acute respiratory distress syndrome). MEASUREMENTS AND MAIN RESULTS: All 11 patients had an abnormal EEG during NO inhalation. EEG-controls without NO showed remarkable improvement. EEG abnormalities were background slowing, low voltage, suppression burst (n = 2), and sharp waves (n = 2) independent of patients' age, NO-indication, and other EEG-influencing parameters. CONCLUSIONS: These preliminary data suggest the occurrence of EEG-abnormalities after application of inhaled NO in critically ill children. We found no correlation with other potential EEG-influencing parameters, although clinical state, medication, or hypoxemia might contribute. Comprehensive, prospective, clinical assessment regarding a causal relationship between NO-inhalation and EEG-abnormalities and their clinical importance is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Critically ill patients depend on artificial nutrition for the maintenance of their metabolic functions and lean body mass, as well as for limiting underfeeding-related complications. Current guidelines recommend enteral nutrition (EN), possibly within the first 48 hours, as the best way to provide the nutrients and prevent infections. EN may be difficult to realize or may be contraindicated in some patients, such as those presenting anatomic intestinal continuity problems or splanchnic ischemia. A series of contradictory trials regarding the best route and timing for feeding have left the medical community with great uncertainty regarding the place of parenteral nutrition (PN) in critically ill patients. Many of the deleterious effects attributed to PN result from inadequate indications, or from overfeeding. The latter is due firstly to the easier delivery of nutrients by PN compared with EN increasing the risk of overfeeding, and secondly to the use of approximate energy targets, generally based on predictive equations: these equations are static and inaccurate in about 70% of patients. Such high uncertainty about requirements compromises attempts at conducting nutrition trials without indirect calorimetry support because the results cannot be trusted; indeed, both underfeeding and overfeeding are equally deleterious. An individualized therapy is required. A pragmatic approach to feeding is proposed: at first to attempt EN whenever and as early as possible, then to use indirect calorimetry if available, and to monitor delivery and response to feeding, and finally to consider the option of combining EN with PN in case of insufficient EN from day 4 onwards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/Aims: Cognitive dysfunction after medical treatment is increasingly being recognized. Studies on this topic require repeated cognitive testing within a short time. However, with repeated testing, practice effects must be expected. We quantified practice effects in a demographically corrected summary score of a neuropsychological test battery repeatedly administered to healthy elderly volunteers. Methods: The Consortium to Establish a Registry for Alzheimer's Disease (CERAD) Neuropsychological Assessment Battery (for which a demographically corrected summary score was developed), phonemic fluency tests, and trail-making tests were administered in healthy volunteers aged 65 years or older on days 0, 7, and 90. This battery allows calculation of a demographically adjusted continuous summary score. Results: Significant practice effects were observed in the CERAD total score and in the word list (learning and recall) subtest. Based on these volunteer data, we developed a threshold for diagnosis of postoperative cognitive dysfunction (POCD) with the CERAD total score. Conclusion: Practice effects with repeated administration of neuropsychological tests must be accounted for in the interpretation of such tests. Ignoring practice effects may lead to an underestimation of POCD. The usefulness of the proposed demographically adjusted continuous score for cognitive function will have to be tested prospectively in patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Specialized pediatric cancer centers (PCCs) are thought to be essential to obtain state-of-the-art care for children and adolescents. We determined the proportion of childhood cancer patients not treated in a PCC, and described their characteristics and place of treatment. PROCEDURE: The Swiss Childhood Cancer Registry (SCCR) registers all children treated in Swiss PCCs. The regional cancer registries (covering 14/26 cantons) register all cancer patients of a region. The children of the SCCR with data from 7 regions (11 cantons) were compared, using specialized software for record linkage. All children <16 years of age at diagnosis with primary malignant tumors, diagnosed between 1990 and 2004, and living in one of these regions were included in the analysis. RESULTS: 22.1% (238/1,077) of patients recorded in regional registries were not registered in the SCCR. Of these, 15.7% (169/1,077) had never been in a PCC while 6.4% (69/1,077) had been in a PCC but were not registered in the SCCR, due to incomplete data flow. In all diagnostic groups and in all age groups, a certain proportion of children was treated outside a PCC, but this proportion was largest in children suffering from malignant bone tumors/soft tissue sarcomas and from malignant epithelial neoplasms, and in older children. The proportion of patients treated in a PCC increased over the study period (P < 0.0001). CONCLUSIONS: One in six childhood cancer patients in Switzerland was not treated in a PCC. Whether these patients have different treatment outcomes remained unclear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Increased respiratory pattern variability is associated with improved oxygenation. Pressure support (PS) is a widely used partial-assist mechanical ventilation (MV) mode, in which each breathing cycle is initiated by flow or pressure variation at the airway due to patient inspiratory effort. Neurally adjusted ventilatory assist (NAVA) is relatively new and uses the electrical activity of the diaphragm (Eadi) to deliver ventilatory support proportional to the patient's inspiratory demand. We hypothesize that respiratory variability should be greater with NAVA compared with PS.Methods: Twenty-two patients underwent 20 minutes of PS followed by 20 minutes of NAVA. Flow and Eadi curves were used to obtain tidal volume (Vt) and ∫Eadi for 300 to 400 breaths in each patient. Patient-specific cumulative distribution functions (CDF) show the percentage Vt and ∫Eadi within a clinically defined (±10%) variability band for each patient. Values are normalized to patient-specific medians for direct comparison. Variability in Vt (outcome) is thus expressed in terms of variability in ∫Eadi (demand) on the same plot.Results: Variability in Vt relative to variability in ∫Eadi is significantly greater for NAVA than PS (P = 0.00012). Hence, greater variability in outcome Vt is obtained for a given demand in ∫Eadi, under NAVA, as illustrated in Figure 1 for a typical patient. A Fisher 2 × 2 contingency analysis showed that 45% of patients under NAVA had a Vt variability in equal proportion to ∫Eadi variability, versus 0% for PS (P < 0.05).Conclusions: NAVA yields greater variability in tidal volume, relative to ∫Eadi demand, and a better match between Vt and ∫Eadi. These results indicate that NAVA could achieve improved oxygenation compared with PS when sufficient underlying variability in ∫Eadi is present, due to its ability to achieve higher tidal volume variability from a given variability in ∫Eadi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Part I of this review, we have covered basic concepts regarding cardiorespiratory interactions. Here, we put this theoretical framework to practical use. We describe mechanisms underlying Kussmaul's sign and pulsus paradoxus. We review the literature on the use of respiratory variations of blood pressure to evaluate volume status. We show the possibilities of attaining the latter aim by investigating with ultrasonography how the geometry of great veins fluctuates with respiration. We provide a Guytonian analysis of the effects of PEEP on cardiac output. We terminate with some remarks on the potential of positive pressure breathing to induce acute cor pulmonale, and on the cardiovascular mechanisms that at times may underly the failure to wean a patient from the ventilator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Multiple electrode aggregometry (MEA) is a point-of-care test evaluating platelet function and the efficacy of platelet inhibitors. In MEA, electrical impedance of whole blood is measured after addition of a platelet activator. Reduced impedance implies platelet dysfunction or the presence of platelet inhibitors. MEA plays an increasingly important role in the management of perioperative platelet dysfunction. In vitro, midazolam, propofol, lidocaine and magnesium have known antiplatelet effects and these may interfere with MEA interpretation. OBJECTIVE: To evaluate the extent to which MEA is modified in the presence of these drugs. DESIGN: An in-vitro study using blood collected from healthy volunteers. SETTING: Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland, 2010 to 2011. PATIENTS: Twenty healthy volunteers. INTERVENTION: Measurement of baseline MEA was using four activators: arachidonic acid, ADP, TRAP-6 and collagen. The study drugs were then added in three increasing, clinically relevant concentrations. MAIN OUTCOME MEASURE: MEA was compared with baseline for each study drug. RESULTS: Midazolam, propofol and lidocaine showed no effect on MEA at any concentration. Magnesium at 2.5 mmol l had a significant effect on the ADP and TRAP tests (31 ± 13 and 96 ± 39 AU, versus 73 ± 21 and 133 ± 28 AU at baseline, respectively), and a less pronounced effect at 1 mmol l on the ADP test (39 ± 0 AU). CONCLUSION: Midazolam, propofol and lidocaine do not interfere with MEA measurement. In patients treated with high to normal doses of magnesium, MEA results for ADP and TRAP-tests should be interpreted with caution. TRIAL REGISTRATION: Clinicaltrials.gov (no. NCT01454427).