60 resultados para parenteral solution
em Université de Lausanne, Switzerland
Resumo:
Introduction: The pharmaceutical aspects of drug administration in clinical trials receive poor consideration compared with the important attention devoted to the analytical and mathematical aspects of biological sample exploitation. During PK calculations, many researchers merely use for dose the nominal amount declared, overlooking the noticeable biases that may result in the assessment of PK parameters. The aim of this work was to evaluate the biases related to doses injected of a biosimilar drug in 2 Phase I clinical trials. Patients (or Materials) and Methods: In trial A, 12 healthy volunteers received different doses of a biosimilar of interferon beta-1a by either subcutaneous (SC) or intravenous (IV) injection. The doses were prepared by partially emptying 0.5-mL syringes supplied by the manufacturer (drop count procedure). In trial B, 12 healthy volunteers received 3 different formulations of the drug by IV injection (biosimilar without albumin [HSA], biosimilar with HSA and original brand [Rebif®]) and 2 different formulations as multiple SC injections (biosimilar HSA-free and original brand). In both trials, the actual dose administered was calculated as: D = C·V - losses. The product titer C was assessed by ELISA. The volume administered IV was assessed by weighting. Losses were evaluated by in vitro experiments. Finally, the binding of 125I-interferon to HSA was evaluated by counting the free and HSA complexed molecule fractions separated by gel filtration. Results: Interferon was not significantly adsorbed onto the lines used for its IV administration. In trial A, the titer was very close to the one declared (96 ± 7%). In trial B, it differed significantly (156 ± 10% for biosimilar with/without HSA and 123 ± 5% for original formulation). In trial A, the dose actually administered showed a large variability. The real injected volume could be biased up to 75% compared with the theoretical volume (for the lower dose administered [ie, 0.03 mL]). This was mainly attributed to a partial re-aspiration of the drug solution before withdrawing the syringe needle. A strict procedure was therefore applied in trial B to avoid these inaccuracies. Finally, in trial B, 125I-Interferon beta-1a binding to HSA appeared time dependent and slow, reaching 50% after 16-hour incubation, which is close to steady state reported for the comparator Rebif®. Conclusion: These practical examples (especially biases on actual titer and volume injected) illustrate that actual dose assessment deserves attention to ensure accuracy for estimates of clearance and distribution volume in the scientific literature and for registration purposes, especially for bioequivalence studies.
Resumo:
Critically ill patients depend on artificial nutrition for the maintenance of their metabolic functions and lean body mass, as well as for limiting underfeeding-related complications. Current guidelines recommend enteral nutrition (EN), possibly within the first 48 hours, as the best way to provide the nutrients and prevent infections. EN may be difficult to realize or may be contraindicated in some patients, such as those presenting anatomic intestinal continuity problems or splanchnic ischemia. A series of contradictory trials regarding the best route and timing for feeding have left the medical community with great uncertainty regarding the place of parenteral nutrition (PN) in critically ill patients. Many of the deleterious effects attributed to PN result from inadequate indications, or from overfeeding. The latter is due firstly to the easier delivery of nutrients by PN compared with EN increasing the risk of overfeeding, and secondly to the use of approximate energy targets, generally based on predictive equations: these equations are static and inaccurate in about 70% of patients. Such high uncertainty about requirements compromises attempts at conducting nutrition trials without indirect calorimetry support because the results cannot be trusted; indeed, both underfeeding and overfeeding are equally deleterious. An individualized therapy is required. A pragmatic approach to feeding is proposed: at first to attempt EN whenever and as early as possible, then to use indirect calorimetry if available, and to monitor delivery and response to feeding, and finally to consider the option of combining EN with PN in case of insufficient EN from day 4 onwards.
Resumo:
Only few cases of classical phenylketonuria (PKU) in premature infants have been reported. Treatment of these patients is challenging due to the lack of a phenylalanine-free amino acid solution for parenteral infusion. The boy was born at 27 weeks of gestation with a weight of 1000 g (P10). He received parenteral nutrition with a protein intake of 3 g/kg/day. On day 7 he was diagnosed with classical PKU (genotype IVS10-11G>A/IVS12+ 1G>A) due to highly elevated phenylalanine (Phe) level in newborn screening (2800 micromol/L). His maximum plasma Phe level reached 3696 micromol/L. Phe intake was stopped for 4 days. During this time the boy received intravenous glucose and lipids as well as little amounts of Phe-free formula by a nasogastric tube. Due to a deficit of essential amino acids and insufficient growth, a parenteral nutrition rich in branched-chain amino-acids and relatively poor in Phe was added, in order to promote protein synthesis without overloading in Phe. Under this regimen, Phe plasma levels normalized on day 19 when intake of natural protein was started. The boy has now a corrected age of 2 years. He shows normal growth parameters and psychomotor development. Despite a long period of highly elevated Phe levels in the postnatal period our patient shows good psychomotor development. The management of premature infants with PKU depends on the child's tolerance to enteral nutrition. It demands an intensive follow-up by an experienced team and dedicated dietician. Appropriate Phe-free parenteral nutrition would be necessary especially in case of gastro-intestinal complications of prematurity.
Resumo:
Continuous respiratory exchange measurements were performed on 10 healthy young women for 1 h before, 3 h during, and 3 h after either parenteral (iv) or intragastric (ig) administration of a nutrient mixture (52% glucose, 18% amino acid, and 30% lipid energy) infused at twice the postabsorptive resting energy expenditure (REE). REE rose from 0.98 +/- 0.02 (iv) and 0.99 +/- 0.02 kcal/min (ig) postabsorptively to 1.13 +/- 0.03 (iv) and 1.13 +/- 0.02 kcal/min (ig), resulting in nutrient-induced thermogenesis of 10 +/- 0.6 and 9.3 +/- 0.9%, respectively, when related to the metabolizable energy. The respiratory quotient rose from preinfusion values of 0.81 +/- 0.02 (iv) and 0.80 +/- 0.01 (ig) to 0.86 +/- 0.01 (iv) and 0.85 +/- 0.01 (ig). After nutrient administration the respiratory quotient fell significantly to below the preinfusion values. Plasma glucose and insulin concentrations rose during nutrient administration but were higher during the intravenous route. It is concluded that, although the response time to intragastric administration was delayed, the thermic effects and overall substrate oxidations were comparable during intravenous or intragastric administration, albeit, at lower plasma glucose and insulin concentrations via the intragastric route.
Resumo:
As part of a project to use the long-lived (T(1/2)=1200a) (166m)Ho as reference source in its reference ionisation chamber, IRA standardised a commercially acquired solution of this nuclide using the 4pibeta-gamma coincidence and 4pigamma (NaI) methods. The (166m)Ho solution supplied by Isotope Product Laboratories was measured to have about 5% Europium impurities (3% (154)Eu, 0.94% (152)Eu and 0.9% (155)Eu). Holmium had therefore to be separated from europium, and this was carried out by means of ion-exchange chromatography. The holmium fractions were collected without europium contamination: 162h long HPGe gamma measurements indicated no europium impurity (detection limits of 0.01% for (152)Eu and (154)Eu, and 0.03% for (155)Eu). The primary measurement of the purified (166m)Ho solution with the 4pi (PC) beta-gamma coincidence technique was carried out at three gamma energy settings: a window around the 184.4keV peak and gamma thresholds at 121.8 and 637.3keV. The results show very good self-consistency, and the activity concentration of the solution was evaluated to be 45.640+/-0.098kBq/g (0.21% with k=1). The activity concentration of this solution was also measured by integral counting with a well-type 5''x5'' NaI(Tl) detector and efficiencies computed by Monte Carlo simulations using the GEANT code. These measurements were mutually consistent, while the resulting weighted average of the 4pi NaI(Tl) method was found to agree within 0.15% with the result of the 4pibeta-gamma coincidence technique. An ampoule of this solution and the measured value of the concentration were submitted to the BIPM as a contribution to the Système International de Référence.
Resumo:
The aim of this study is to perform a thorough comparison of quantitative susceptibility mapping (QSM) techniques and their dependence on the assumptions made. The compared methodologies were: two iterative single orientation methodologies minimizing the l2, l1TV norm of the prior knowledge of the edges of the object, one over-determined multiple orientation method (COSMOS) and anewly proposed modulated closed-form solution (MCF). The performance of these methods was compared using a numerical phantom and in-vivo high resolution (0.65mm isotropic) brain data acquired at 7T using a new coil combination method. For all QSM methods, the relevant regularization and prior-knowledge parameters were systematically changed in order to evaluate the optimal reconstruction in the presence and absence of a ground truth. Additionally, the QSM contrast was compared to conventional gradient recalled echo (GRE) magnitude and R2* maps obtained from the same dataset. The QSM reconstruction results of the single orientation methods show comparable performance. The MCF method has the highest correlation (corrMCF=0.95, r(2)MCF =0.97) with the state of the art method (COSMOS) with additional advantage of extreme fast computation time. The l-curve method gave the visually most satisfactory balance between reduction of streaking artifacts and over-regularization with the latter being overemphasized when the using the COSMOS susceptibility maps as ground-truth. R2* and susceptibility maps, when calculated from the same datasets, although based on distinct features of the data, have a comparable ability to distinguish deep gray matter structures.
Resumo:
http://resfranco.cochrane.org/sites/resfranco.cochrane.org/files/uploads/Arrettabac2009.pdf
Resumo:
BACKGROUND & AIMS: n-3 fatty acids are expected to downregulate the inflammatory responses, and hence may decrease insulin resistance. On the other hand, n-3 fatty acid supplementation has been reported to increase glycemia in type 2 diabetes. We therefore assessed the effect of n-3 fatty acids delivered with parenteral nutrition on glucose metabolism in surgical intensive care patients. METHODS: Twenty-four surgical intensive care patients were randomized to receive parenteral nutrition providing 1.25 times their fasting energy expenditure, with 0.25 g of either an n-3 fatty acid enriched-or a soy bean-lipid emulsion. Energy metabolism, glucose production, gluconeogenesis and hepatic de novo lipogenesis were evaluated after 4 days. RESULTS: Total energy expenditure was significantly lower in patients receiving n-3 fatty acids (0.015+/-0.001 vs. 0.019+/-0.001 kcal/kg/min with soy bean lipids (P<0.05)). Glucose oxidation, lipid oxidation, glucose production, gluconeogenesis, hepatic de novo lipogenesis, plasma glucose, insulin and glucagon concentrations did not differ (all P>0.05) in the 2 groups. CONCLUSIONS: n-3 fatty acids were well tolerated in this group of severely ill patients. They decreased total energy expenditure without adverse metabolic effects.
Resumo:
A new, investigational, parenteral form of sparfloxacin was compared with ceftriaxone in the treatment of experimental endocarditis caused by either of three penicillin-susceptible streptococci or one penicillin-resistant streptococcus. Both drugs have prolonged half-lives in serum, allowing single daily administration to humans. Sparfloxacin had relatively low MICs (0.25 to 0.5 mg/liter) for all four organisms and was also greater than or equal to eight times more effective than the other quinolones against 21 additional streptococcal isolates recovered from patients with bacteremia. Ceftriaxone MICs were 0.032 to 0.064 mg/liter for the penicillin-susceptible strains and 2 mg/liter for the resistant isolate. Both antibiotics resulted in moderate bacterial killing in vitro. Rats with catheter-induced aortic vegetations were inoculated with 10(7) CFU of the test organisms. Antibiotic treatment was started 48 h later and lasted either 3 or 5 days. The drugs were injected at doses which mimicked the kinetics in human serum produced by one intravenous injection of 400 mg of sparfloxacin (i.e., the daily dose expected to be given to human adults) and 2 g of ceftriaxone. Both antibiotics significantly decreased the bacterial densities in the vegetations. However, sparfloxacin was slower than ceftriaxone in its ability to eradicate valvular infection caused by penicillin-susceptible bacteria. While this difference was quite marked after 3 days of therapy, it tended to vanish when treatment was prolonged to 5 days. In contrast, sparfloxacin was very effective against the penicillin-resistant isolate, an organism against which ceftriaxone therapy failed in vivo. No sparfloxacin-resistant mutant was selected during therapy. Thus, in the present experimental setting, this new, investigational, parenteral form of sparfloxacin was effective against severe infections caused by both penicillin-susceptible and penicillin-resistant streptococci.
Resumo:
Undernutrition is a widespread problem in intensive care unit and is associated with a worse clinical outcome. A state of negative energy balance increases stress catabolism and is associated with increased morbidity and mortality in ICU patients. Undernutrition-related increased morbidity is correlated with an increase in the length of hospital stay and health care costs. Enteral nutrition is the recommended feeding route in critically ill patients, but it is often insufficient to cover the nutritional needs. The initiation of supplemental parenteral nutrition, when enteral nutrition is insufficient, could optimize the nutritional therapy by preventing the onset of early energy deficiency, and thus, could allow to reduce morbidity, length of stay and costs, shorten recovery period and, finally, improve quality of life. (C) 2009 Elsevier Masson SAS. All rights reserved.
Resumo:
OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.