66 resultados para optimization of the fracture parameters

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integrating and expressing stably a transgene into the cellular genome remain major challenges for gene-based therapies and for bioproduction purposes. While transposon vectors mediate efficient transgene integration, expression may be limited by epigenetic silencing, and persistent transposase expression may mediate multiple transposition cycles. Here, we evaluated the delivery of the piggyBac transposase messenger RNA combined with genetically insulated transposons to isolate the transgene from neighboring regulatory elements and stabilize expression. A comparison of piggyBac transposase expression from messenger RNA and DNA vectors was carried out in terms of expression levels, transposition efficiency, transgene expression and genotoxic effects, in order to calibrate and secure the transposition-based delivery system. Messenger RNA reduced the persistence of the transposase to a narrow window, thus decreasing side effects such as superfluous genomic DNA cleavage. Both the CTF/NF1 and the D4Z4 insulators were found to mediate more efficient expression from a few transposition events. We conclude that the use of engineered piggyBac transposase mRNA and insulated transposons offer promising ways of improving the quality of the integration process and sustaining the expression of transposon vectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human connectome represents a network map of the brain's wiring diagram and the pattern into which its connections are organized is thought to play an important role in cognitive function. The generative rules that shape the topology of the human connectome remain incompletely understood. Earlier work in model organisms has suggested that wiring rules based on geometric relationships (distance) can account for many but likely not all topological features. Here we systematically explore a family of generative models of the human connectome that yield synthetic networks designed according to different wiring rules combining geometric and a broad range of topological factors. We find that a combination of geometric constraints with a homophilic attachment mechanism can create synthetic networks that closely match many topological characteristics of individual human connectomes, including features that were not included in the optimization of the generative model itself. We use these models to investigate a lifespan dataset and show that, with age, the model parameters undergo progressive changes, suggesting a rebalancing of the generative factors underlying the connectome across the lifespan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a phenomenologically motivated magneto-mechanically coupled finite strain elastic framework for simulating the curing process of polymers in the presence of a magnetic load is proposed. This approach is in line with previous works by Hossain and co-workers on finite strain curing modelling framework for the purely mechanical polymer curing (Hossain et al., 2009b). The proposed thermodynamically consistent approach is independent of any particular free energy function that may be used for the fully-cured magneto-sensitive polymer modelling, i.e. any phenomenological or micromechanical-inspired free energy can be inserted into the main modelling framework. For the fabrication of magneto-sensitive polymers, micron-size ferromagnetic particles are mixed with the liquid matrix material in the uncured stage. The particles align in a preferred direction with the application of a magnetic field during the curing process. The polymer curing process is a complex (visco) elastic process that transforms a fluid to a solid with time. Such transformation process is modelled by an appropriate constitutive relation which takes into account the temporal evolution of the material parameters appearing in a particular energy function. For demonstration in this work, a frequently used energy function is chosen, i.e. the classical Mooney-Rivlin free energy enhanced by coupling terms. Several representative numerical examples are demonstrated that prove the capability of our approach to correctly capture common features in polymers undergoing curing processes in the presence of a magneto-mechanical coupled load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of ORAMED work package 4 was the optimization of the medical practices in nuclear medicine during the preparation of radiopharmaceuticals and their administration to the patient. During the project a wide campaign of measurements was performed in the nuclear medicine departments of the collaborating hospitals. Such data were intrinsically characterized by a large variability that depended on the procedure, the employed techniques and the operator's habits. That variability could easily hide some important parameter, for example, the effectiveness of the adopted shielding (for syringe and vial) or the effect of the distances from the source. This information is necessary for a valuable optimization purpose of radiation protection. To this end a sensitivity analysis was carried out through Monte Carlo simulations employing voxel models, representing operator's hand during the considered practices. Such analysis allowed understanding at what extent the range of personal dose equivalent evaluated during measurements can be considered intrinsically related to the procedures. Furthermore, with the Monte Carlo simulations it was possible to study the appropriateness of the shielding usually utilized in these practices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Richer and healthier agents tend to hold riskier portfolios and spend proportionally less on health expenditures. Potential explanations include health and wealth effects on preferences, expected longevity or disposable total wealth. Using HRS data, we perform a structural estimation of a dynamic model of consumption, portfolio and health expenditure choices with recursive utility, as well as health-dependent income and mortality risk. Our estimates of the deep parameters highlight the importance of health capital, mortality risk control, convex health and mortality adjustment costs and binding liquidity constraints to rationalize the stylized facts. They also provide new perspectives on expected longevity and on the values of life and health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Greenstick fractures suffered during growth have a high risk for refracture and posttraumatic deformity, particularly at the forearm diaphysis. The use of a preemptive completion of the fracture by manipulation of the concave cortex is controversial and data supporting this approach are few. AIM: Aim of this study was to determine the factors which predispose to refracture and deformities, and to define therapeutic strategies. METHODS: We prospectively gathered clinical and radiographic data over a period of one year on greenstick fractures of the middle third of the forearm in children as part of a multi-centre study. Endpoint was a follow-up visit at one year. Radiographic deformity, state of consolidation at resumption of physical activities and refracture rate were analysed statistically (ANOVA, Student's t-test and Pearson's chi-square test) with regard to patient age, gender, fracture type, therapy and time in plaster. RESULTS: We collected the data of 103 patients (63 boys, 40 girls), average age 6.6 years (1.3-14.5 years), the vast majority of whom had a combined greenstick fracture of the radius and ulna. 6.7% of the patients sustained a refracture within 49 days (29-76) after plaster removal. They were significantly older (p=0.017) with a significantly higher incidence of manual completion of the fracture with radiographic signs of partial consolidation (p=0.025). Residual deformities were significantly smaller after completion of the fracture compared to reduction without completion (p=0.019) or plaster fixation alone (p<0.005). CONCLUSIONS: Completion of a greenstick fracture does not prevent refracture. Nevertheless, it diminishes the extent of secondary deformities in cases where the primary angulation exceeds the remodelling capacity. Prevention of refracture should include a routine radiographic follow-up 4-6 weeks after injury with continuation of plaster fixation in cases of partial consolidation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plain film radiography often underestimates the extent of injury in children with epiphyseal fracture. Especially Salter-Harris V fractures (crush fracture of the epiphyseal plate) are often primarily not detected. MRI of the ankle was performed in 10 children aged 9-17 (mean 14) years with suspected epiphyseal injury using 1.0-T Magnetom Expert. The fractures were classified according to the Salter-Harris-Rang-Odgen classification and compared with the results of plain radiography. In one case MRI could exclude epiphyseal injury; in four cases the MRI findings changed the therapeutic management. The visualisation of the fracture in three orthogonal planes and the possibility of detection of cartilage and ligamentous injury in MR imaging makes this method superior to conventional radiography and CT. With respect to radiation exposure MRI instead of CT should be used for the diagnosis of epiphyseal injuries in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider robust parametric procedures for univariate discrete distributions, focusing on the negative binomial model. The procedures are based on three steps: ?First, a very robust, but possibly inefficient, estimate of the model parameters is computed. ?Second, this initial model is used to identify outliers, which are then removed from the sample. ?Third, a corrected maximum likelihood estimator is computed with the remaining observations. The final estimate inherits the breakdown point (bdp) of the initial one and its efficiency can be significantly higher. Analogous procedures were proposed in [1], [2], [5] for the continuous case. A comparison of the asymptotic bias of various estimates under point contamination points out the minimum Neyman's chi-squared disparity estimate as a good choice for the initial step. Various minimum disparity estimators were explored by Lindsay [4], who showed that the minimum Neyman's chi-squared estimate has a 50% bdp under point contamination; in addition, it is asymptotically fully efficient at the model. However, the finite sample efficiency of this estimate under the uncontaminated negative binomial model is usually much lower than 100% and the bias can be strong. We show that its performance can then be greatly improved using the three step procedure outlined above. In addition, we compare the final estimate with the procedure described in

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.