4 resultados para online course materials

em Université de Lausanne, Switzerland


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Pearson marrow-pancreas syndrome (PS) is usually a fatal mitochondrial disease, mostly diagnosed during infancy or postmortem. PS is caused by the deletions or duplications of mitochondrial DNA (mtDNA). The tissue distribution and relative proportions of expressed abnormal mtDNA determine the phenotype and the clinical course. MATERIALS AND METHODS: We describe the case of a term baby boy who was diagnosed with PS early in the neonatal period due to severe aregenerative anemia and persistent lactic acidosis. RESULTS: His neurological examination was abnormal since birth. Brain magnetic resonance imaging (MRI) at term was abnormal, indicating that mitochondrial encephalopathy in PS can be already manifested in the neonatal period. To our knowledge, neonatal encephalopathy in PS has not been previously described. CONCLUSION: PS is a rare condition diagnosed in the newborn. It should be suspected in the presence of severe anemia and persistent lactic acidosis, and may manifest with early encephalopathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Optimal induction and maintenance immunosuppressive therapies in renal transplantation are still a matter of debate.Chronic corticosteroid usage is a major cause of morbidity but steroid-free immunosuppression (SF) can result in unacceptably high rates of acute rejection and even graft loss. Methods and materials: We have conducted a prospective openlabelled clinical trial in the Geneva-Lausanne Transplant Network from March 2005 to May 2008. 20 low immunological risk (<20% PRA, no DSA) adult recipients of a primary kidney allograft received a 4-day course of thymoglobulin (1.5 mg/kg/d) with methylprednisolone and maintenance based immunosuppression of tacrolimus and entericcoated mycophenolic acid (MPA). The control arm consisted of 16 matched recipients treated with basiliximab induction, tacrolimus, mycophenolate mofetil and corticosteroids. Primary endpoints were the percentage of recipients not taking steroids and the percentage of rejection-free recipients at 12 months.Secondary end points were allograft survival at 12 months and significant thymoglobulin and/or other drugs side effects. Results: In the SF group, 85% of the kidney recipients remained steroid-free at 12 months. The 3 cases of steroids introduction were due to one acute tubulo-interstitial rejection occurring at day 11, one tacrolimus withdrawal due to thrombotic microangiopathy and one MPA withdrawal because of multiple sinusitis and CMV reactivations. No BK viremia was detected nor CMV disease. The 6 CMV negative patients who received a positive CMV allograft had a symptomatic primoinfection after their 6-month course valgancyclovir prophylaxis. In the steroid-based group, 3 acute rejection episodes (acute humoral rejection, acute tubulointerstitial Banff IA and vascular Banff IIA) occurred in 2 recipients, 3 BK virus nephropathies were diagnosed between 45 and 135 days post transplant No side effects were associated with thymoglobulin infusion.In the SF group, 4 recipients presented severe leukopenia or agranulocytosis and one recipient had febrile hepatitis leading to transient MPA withdrawal. Discontinuation of MPA was needed in 2 patients for recurrent sinusitis and CMV reactivations. Patient and graft survival was 100% in both groups at 12 month follow-up. Conclusion: Steroid-free with short-course thymoglobulin induction therapy was a safe protocol in low-risk renal transplant recipients. Lower rates of acute rejection and BK virus infections episodes were seen compared to the steroid-based control group. A longer follow-up will be needed to determine whether this SF immunosuppressive regimen will result in higher graft and patient survival.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: (1) To evaluate the changes in surface roughness and gloss after simulated toothbrushing of 9 composite materials and 2 ceramic materials in relation to brushing time and load in vitro; (2) to assess the relationship between surface gloss and surface roughness. METHODS: Eight flat specimens of composite materials (microfilled: Adoro, Filtek Supreme, Heliomolar; microhybrid: Four Seasons, Tetric EvoCeram; hybrid: Compoglass F, Targis, Tetric Ceram; macrohybrid: Grandio), two ceramic materials (IPS d.SIGN and IPS Empress polished) were fabricated according to the manufacturer's instructions and optimally polished with up to 4000 grit SiC. The specimens were subjected to a toothbrushing (TB) simulation device (Willytec) with rotating movements, toothpaste slurry and at three different loads (100g/250g/350g). At hourly intervals from 1h to 10h TB, mean surface roughness Ra was measured with an optical sensor and the surface gloss (Gl) with a glossmeter. Statistical analysis was performed for log-transformed Ra data applying two-way ANOVA to evaluate the interaction between load and material and load and brushing time. RESULTS: There was a significant interaction between material and load as well as between load and brushing time (p<0.0001). The microhybrid and hybrid materials demonstrated more surface deterioration with higher loads, whereas with the microfilled resins Heliomolar and Adoro it was vice versa. For ceramic materials, no or little deterioration was observed over time and independent of the load. The ceramic materials and 3 of the composite materials (roughness) showed no further deterioration after 5h of toothbrushing. Mean surface gloss was the parameter which discriminated best between the materials, followed by mean surface roughness Ra. There was a strong correlation between surface gloss and surface roughness for all the materials except the ceramics. The evaluation of the deterioration curves of individual specimens revealed a more or less synchronous course suspecting hinting specific external conditions and not showing the true variability in relation to the tested material. SIGNIFICANCE: The surface roughness and gloss of dental materials changes with brushing time and load and thus results in different material rankings. Apart from Grandio, the hybrid composite resins were more prone to surface changes than microfilled composites. The deterioration potential of a composite material can be quickly assessed by measuring surface gloss. For this purpose, a brushing time of 10h (=72,000 strokes) is needed. In further comparative studies, specimens of different materials should be tested in one series to estimate the true variability.