8 resultados para occupational noise

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Highway maintenance workers are constantly and simultaneously exposed to traffic-related particle and noise emissions, and both have been linked to increased cardiovascular morbidity and mortality in population-based epidemiology studies. OBJECTIVES: We aimed to investigate short-term health effects related to particle and noise exposure. METHODS: We monitored 18 maintenance workers, during as many as five 24-hour periods from a total of 50 observation days. We measured their exposure to fine particulate matter (PM2.5), ultrafine particles, noise, and the cardiopulmonary health endpoints: blood pressure, pro-inflammatory and pro-thrombotic markers in the blood, lung function and fractional exhaled nitric oxide (FeNO) measured approximately 15 hours post-work. Heart rate variability was assessed during a sleep period approximately 10 hours post-work. RESULTS: PM2.5 exposure was significantly associated with C-reactive protein and serum amyloid A, and negatively associated with tumor necrosis factor α. None of the particle metrics were significantly associated with von Willebrand factor or tissue factor expression. PM2.5 and work noise were associated with markers of increased heart rate variability, and with increased HF and LF power. Systolic and diastolic blood pressure on the following morning were significantly associated with noise exposure after work, and non-significantly associated with PM2.5. We observed no significant associations between any of the exposures and lung function or FeNO. CONCLUSIONS: Our findings suggest that exposure to particles and noise during highway maintenance work might pose a cardiovascular health risk. Actions to reduce these exposures could lead to better health for this population of workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computerized handheld procedure is presented in this paper. It is intended as a database complementary tool, to enhance prospective risk analysis in the field of occupational health. The Pendragon forms software (version 3.2) has been used to implement acquisition procedures on Personal Digital Assistants (PDAs) and to transfer data to a computer in an MS-Access format. The data acquisition strategy proposed relies on the risk assessment method practiced at the Institute of Occupational Health Sciences (IST). It involves the use of a systematic hazard list and semi-quantitative risk assessment scales. A set of 7 modular forms has been developed to cover the basic need of field audits. Despite the minor drawbacks observed, the results obtained so far show that handhelds are adequate to support field risk assessment and follow-up activities. Further improvements must still be made in order to increase the tool effectiveness and field adequacy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exposure to dust and polynuclear aromatic hydrocarbons (PAH) of 15 truck drivers from Geneva, Switzerland, was measured. The drivers were divided between "long-distance" drivers and "local" drivers and between smokers and nonsmokers and were compared with a control group of 6 office workers who were also divided into smokers and nonsmokers. Dust was measured on 1 workday both by a direct-reading instrument and by sampling. The local drivers showed higher exposure to dust (0.3 mg/m3) and PAH than the long-distance drivers (0.1 mg/m3), who showed no difference with the control group. This observation may be due to the fact that the local drivers spend more time in more polluted areas, such as streets with heavy traffic and construction sites, than do the long-distance drivers. Smoking does not influence exposure to dust and PAH of professional truck drivers, as measured in this study, probably because the ventilation rate of the truck cabins is relatively high even during cold days (11-15 r/h). The distribution of dust concentrations was shown in some cases to be quite different from the expected log-normal distribution. The contribution of diesel exhaust to these exposures could not be estimated since no specific tracer was used. However, the relatively low level of dust exposure dose not support the hypothesis that present day levels of diesel exhaust particulates play a significant role in the excess occurrence of lung cancer observed in professional truck drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polychlorinated biphenyls (PCBs) are carcinogenic. Estimating PCB half-life in the body based on levels in sera from exposed workers is complicated by the fact that occupational exposure to PCBs was to commercial PCB products (such as Aroclors 1242 and 1254) comprised of varying mixtures of PCB congeners. Half-lives were estimated using sera donated by 191 capacitor manufacturing plant workers in 1976 during PCB use (1946-1977), and post-exposure (1979, 1983, and 1988). Our aims were to: (1) determine the role of covariates such as gender on the half-life estimates, and (2) compare our results with other published half-life estimates based on exposed workers. All serum PCB levels were adjusted for PCB background levels. A linear spline model with a single knot was used to estimate two separate linear equations for the first two serum draws (Equation A) and the latter two (Equation B). Equation A gave half-life estimates of 1.74 years and 6.01 years for Aroclor 1242 and Aroclor 1254, respectively. Estimates were 21.83 years for Aroclor 1242 and 133.33 years for Aroclor 1254 using Equation B. High initial body burden was associated with rapid PCB elimination in workers at or shortly after the time they were occupationally exposed and slowed down considerably when the dose reached background PCB levels. These concentration-dependent half-life estimates had a transition point of 138.57 and 34.78 ppb for Aroclor 1242 and 1254, respectively. This result will help in understanding the toxicological and epidemiological impact of exposure to PCBs in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Because of its high prevalence, early screening for occupational asthma (OA) is crucial. We aimed to evaluate the screening performance of the Occupational Asthma Screening Questionnaire-11 items (OASQ-11) in a clinical setting. METHODS: Between January 2009 and December 2011, 169 workers referred for potential OA to our hospital completed the OASQ-11 and underwent workups to determine the final diagnosis. The discriminative abilities of the OASQ-11 as a whole and in relation to demographic and exposure parameters were determined by the area under the receiving operator characteristic curve (AUC). RESULTS: Model 1, consisting of the OASQ's items, showed fair discrimination (AUC, 0.69; 95% confidence interval, 0.58 to 0.80). Addition of age and exposure duration to model 1 improved discrimination (AUC, 0.80; confidence interval, 0.72 to 0.88). CONCLUSION: A simple model consisting of the OASQ-11's items, age, and exposure duration could well discriminate subjects with OA in a clinical setting.