193 resultados para nuclear resonance, medical diagnostic, lung

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies in adults have shown that late gadolinium enhanced cardiac magnetic resonance is a safe and noninvasive diagnostic tool which allows one to differentiate myocardial infarction from myocarditis. We believe that it may also be highly useful in the paediatric population for the same purpose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Toperform a meta-analysis of FDG-PET performances in the diagnosis of largevessels vasculitis (Giant Cell Arteritis (GCA) associated or not withPolymyalgia Rheumatica(PMR), Takayasu). Materials and methods : The MEDLINE,Cochrane Library, Embase were searched for relevant original articlesdescribing FDG-PET for vasculitis assessment, using MesH terms ("GiantCell Arteritis or Vasculitis" AND "PET"). Criteria for inclusionwere:(1)FDG-PET for diagnosis of vasculitis(2)American College of Rheumatologycriteria as reference standard(3)control group. After data extraction, analyseswere performed using a random-effects model. Results : Of 184 citations(database search and references screening),70 articles were reviewed of which12 eligible studies were extracted (sensitivity range from 32% to 97%). 7studies fulfilled all inclusion criteria. Owing to overlapping population, 1study was excluded. Statistical heterogeneity justified the random-effectsmodel. Pooled 6 studies analysis(116 vasculitis,224 controls) showed a 81%sensitivity (95%CI:70-89%);a 89% specificity (95%CI:77-95%);a 85%PPV(95%CI:63-95%); a 90% NPV(95%CI:79-95%);a 7.1 positive LR(95%CI:3.4-14.9); a0.2 negative LR(95%CI:0.14-0.35) and 90.1 DOR(95%CI: 18.6-437). Conclusion :FDG-PET has good diagnostic performances in the detection of large vesselsvasculitis. Its promising role could be extended to follow up patients undertreatment, but further studies are needed to confirm this possibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Inhalation of bioaerosols has been hypothesised to cause "toxic pneumonitis" that should increase lung epithelial permeability at the bronchioloalveolar level. Serum Clara cell protein (CC16) and serum surfactant protein B (SPB) have been proposed as sensitive markers of lung epithelial injury. This study was aimed at looking for increased lung epithelial permeability by determining CC16 and SPB in workers exposed to bioaerosols from wastewater or garbage. METHODS: Subjects (778 wastewater, garbage and control workers; participation 61%) underwent a medical examination, lung function tests [American Thoracic Society (ATS) criteria], and determination of CC16 and SPB. Symptoms of endotoxin exposure and several potential confounders (age, gender, smoking, kidney function, obesity) were looked for. Results were examined with multiple linear or logistic regression. RESULTS: Exposure to bioaerosols increased CC16 concentration in the wastewater workers. No effect of exposure on SPB was found. No clue to work-related respiratory diseases was found. CONCLUSIONS: The increase in CC16 in serum supports the hypothesis that bioaerosols cause subclinical "toxic pneumonitis", even at low exposure. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE:: Lactic acid bacteria (LAB) are used in food industries as probiotic agents. The aim of this study is to assess the potential health effects of airborne exposure to a mix of preblend (LAB and carbohydrate) and milk powder in workers. METHODS:: A medical questionnaire, lung function tests, and immunologic tests were carried out on 50 workers. Occupational exposure to inhalable dust and airborne LAB was measured. RESULTS:: Workers not using respiratory masks reported more symptoms of irritation than workers using protection. Workers from areas with higher levels of airborne LAB reported the most health symptoms and the immune responses of workers to LAB was higher than the immune responses of a control population. CONCLUSIONS:: Measures to reduce exposure to airborne LAB and milk powder in food industries are recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The knowledge of the relationship that links radiation dose and image quality is a prerequisite to any optimization of medical diagnostic radiology. Image quality depends, on the one hand, on the physical parameters such as contrast, resolution, and noise, and on the other hand, on characteristics of the observer that assesses the image. While the role of contrast and resolution is precisely defined and recognized, the influence of image noise is not yet fully understood. Its measurement is often based on imaging uniform test objects, even though real images contain anatomical backgrounds whose statistical nature is much different from test objects used to assess system noise. The goal of this study was to demonstrate the importance of variations in background anatomy by quantifying its effect on a series of detection tasks. Several types of mammographic backgrounds and signals were examined by psychophysical experiments in a two-alternative forced-choice detection task. According to hypotheses concerning the strategy used by the human observers, their signal to noise ratio was determined. This variable was also computed for a mathematical model based on the statistical decision theory. By comparing theoretical model and experimental results, the way that anatomical structure is perceived has been analyzed. Experiments showed that the observer's behavior was highly dependent upon both system noise and the anatomical background. The anatomy partly acts as a signal recognizable as such and partly as a pure noise that disturbs the detection process. This dual nature of the anatomy is quantified. It is shown that its effect varies according to its amplitude and the profile of the object being detected. The importance of the noisy part of the anatomy is, in some situations, much greater than the system noise. Hence, reducing the system noise by increasing the dose will not improve task performance. This observation indicates that the tradeoff between dose and image quality might be optimized by accepting a higher system noise. This could lead to a better resolution, more contrast, or less dose.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: In spite of robust knowledge about underlying ischemic myocardial damage, acute coronary syndromes (ACS) with culprit-free angiograms raise diagnostic concerns. The present study aimed to evaluate the additional value of cardiac magnetic resonance (CMR) over commonly available non-CMR standard tests, for the differentiation of myocardial injury in patients with ACS and non-obstructed coronary arteries. MATERIAL/METHODS: Patients with ACS, elevated hs-TnT, and a culprit-free angiogram were prospectively enrolled into the study between January 2009 and July 2013. After initial evaluation with standard tests (ECG, echocardiography, hs-TnT) and provisional exclusion of acute myocardial infarction (AMI) in coronary angiogram, patients were referred for CMR with the suspicion of myocarditis or Takotsubo cardiomyopathy (TTC). According to the result of CMR, patients were reclassified as having myocarditis, AMI, TTC, or non-injured myocardium as assessed by late gadolinium enhancement. RESULTS: Out of 5110 patients admitted with ACS, 75 had normal coronary angiograms and entered the study; 69 of them (92%) were suspected for myocarditis and 6 (8%) for TTC. After CMR, 49 patients were finally diagnosed with myocarditis (65%), 3 with TTC (4%), 7 with AMI (9%), and 16 (21%) with non-injured myocardium. The provisional diagnosis was changed or excluded in 23 patients (31%), with a 9% rate of unrecognized AMI. CONCLUSIONS: The study results suggest that the evaluation of patients with ACS and culprit-free angiogram should be complemented by a CMR examination, if available, because the initial work-up with non-CMR tests leads to a significant proportion of misdiagnosed AMI.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Cardiovascular magnetic resonance (CMR) has favorable characteristics for diagnostic evaluation and risk stratification of patients with known or suspected CAD. CMR utilization in CAD detection is growing fast. However, data on its cost-effectiveness are scarce. The goal of this study is to compare the costs of two strategies for detection of significant coronary artery stenoses in patients with suspected coronary artery disease (CAD): 1) Performing CMR first to assess myocardial ischemia and/or infarct scar before referring positive patients (defined as presence of ischemia and/or infarct scar to coronary angiography (CXA) versus 2) a hypothetical CXA performed in all patients as a single test to detect CAD. METHODS: A subgroup of the European CMR pilot registry was used including 2,717 consecutive patients who underwent stress-CMR. From these patients, 21% were positive for CAD (ischemia and/or infarct scar), 73% negative, and 6% uncertain and underwent additional testing. The diagnostic costs were evaluated using invoicing costs of each test performed. Costs analysis was performed from a health care payer perspective in German, United Kingdom, Swiss, and United States health care settings. RESULTS: In the public sectors of the German, United Kingdom, and Swiss health care systems, cost savings from the CMR-driven strategy were 50%, 25% and 23%, respectively, versus outpatient CXA. If CXA was carried out as an inpatient procedure, cost savings were 46%, 50% and 48%, respectively. In the United States context, cost savings were 51% when compared with inpatient CXA, but higher for CMR by 8% versus outpatient CXA. CONCLUSION: This analysis suggests that from an economic perspective, the use of CMR should be encouraged as a management option for patients with suspected CAD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The aim of the present report is to describe abnormal (18)F-fluorodeoxyglucose (FDG) accumulation patterns in the pleura and lung parenchyma in a group of lung cancer patients in whom lung infarction was present at the time of positron emission tomography (PET). METHODS: Between November 2002 and December 2003, a total of 145 patients (102 males, 43 females; age range 38-85 years) were subjected to whole-body FDG PET for initial staging (n=117) or restaging (n=11) of lung cancer or for evaluation of solitary pulmonary nodules (n=17). Of these patients, 24 displayed abnormal FDG accumulation in the lung parenchyma that was not consistent with the primary lesion under investigation (ipsilateral n=12, contralateral n=9 or bilateral n=3). Without correlative imaging, this additional FDG uptake would have been considered indeterminate in differential diagnosis. RESULTS: Of the 24 patients who were identified as having such lesions, six harboured secondary tumour nodules diagnosed as metastases, while in three the diagnosis of a synchronous second primary lung tumour was established. Additionally, nine patients were identified as having post-stenotic pneumonia and/or atelectasis (n=6) or granulomatous lung disease (n=3). In the remaining six (4% of all patients), a diagnosis of recent pulmonary embolism that topographically matched the additional FDG accumulation (SUV(max) range 1.4-8.6, mean 3.9) was made. Four of these six patients were known to have pulmonary embolism, and hence false positive interpretation was avoided by correlating the PET findings with those of the pre-existing diagnostic work-up. The remaining two patients were harbouring small occult infarctions that mimicked satellite nodules in the lung periphery. Based on histopathological results, the abnormal FDG accumulation in these two patients was attributed to the inflammatory reaction and tissue repair associated with the pathological cascade of pulmonary embolism. CONCLUSION: In patients with pulmonary malignancies, synchronous lung infarction may induce pathological FDG accumulation that can mimic active tumour manifestations. Identifying this potential pitfall may allow avoidance of false positive FDG PET interpretation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effects of dark-induced stress on the evolution of the soluble metabolites present in senescent soybean (Glycine max L.) nodules were analysed in vitro using (13)C- and (31)P-NMR spectroscopy. Sucrose and trehalose were the predominant soluble storage carbons. During dark-induced stress, a decline in sugars and some key glycolytic metabolites was observed. Whereas 84% of the sucrose disappeared, only one-half of the trehalose was utilised. This decline coincides with the depletion of Gln, Asn, Ala and with an accumulation of ureides, which reflect a huge reduction of the N(2) fixation. Concomitantly, phosphodiesters and compounds like P-choline, a good marker of membrane phospholipids hydrolysis and cell autophagy, accumulated in the nodules. An autophagic process was confirmed by the decrease in cell fatty acid content. In addition, a slight increase in unsaturated fatty acids (oleic and linoleic acids) was observed, probably as a response to peroxidation reactions. Electron microscopy analysis revealed that, despite membranes dismantling, most of the bacteroids seem to be structurally intact. Taken together, our results show that the carbohydrate starvation induced in soybean by dark stress triggers a profound metabolic and structural rearrangement in the infected cells of soybean nodule which is representative of symbiotic cessation.