80 resultados para new method
em Université de Lausanne, Switzerland
Resumo:
MOTIVATION: Microarray results accumulated in public repositories are widely reused in meta-analytical studies and secondary databases. The quality of the data obtained with this technology varies from experiment to experiment, and an efficient method for quality assessment is necessary to ensure their reliability. RESULTS: The lack of a good benchmark has hampered evaluation of existing methods for quality control. In this study, we propose a new independent quality metric that is based on evolutionary conservation of expression profiles. We show, using 11 large organ-specific datasets, that IQRray, a new quality metrics developed by us, exhibits the highest correlation with this reference metric, among 14 metrics tested. IQRray outperforms other methods in identification of poor quality arrays in datasets composed of arrays from many independent experiments. In contrast, the performance of methods designed for detecting outliers in a single experiment like Normalized Unscaled Standard Error and Relative Log Expression was low because of the inability of these methods to detect datasets containing only low-quality arrays and because the scores cannot be directly compared between experiments. AVAILABILITY AND IMPLEMENTATION: The R implementation of IQRray is available at: ftp://lausanne.isb-sib.ch/pub/databases/Bgee/general/IQRray.R. CONTACT: Marta.Rosikiewicz@unil.ch SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Resumo:
A new electrical method is proposed for determining the apparent resistivity of multi-earth layers located underwater. The method is based on direct current geoelectric sounding principles. A layered earth model is used to simulate the stratigraphic target. The measurement array is of pole-pole type; it is located underwater and is orientated vertically. This particular electrode configuration is very useful when conventional electrical methods cannot be used, especially if the water depth becomes very important. The calculated apparent resistivity shows a substantial quality increase in the measured signal caused by the underwater targets, from which little or no response is measured using conventional surface electrode methods. In practice, however, different factors such as water stratification, underwater streams or meteorological conditions complicate the interpretation of the field results. A case study is presented, where field surveys carried out on Lake Geneva were interpreted using the calculated apparent resistivity master-curves.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
A New Method for ECG Tracking of Persistent Atrial Fibrillation Termination during Stepwise Ablation
Resumo:
Stepwise radiofrequency catheter ablation (step-CA) has become the treatment of choice for the restoration of sinus rhythm (SR) in patients with long-standing persistent atrial fibrillation (pers-AF). Its success rate appears limited as the amount of ablation to achieve long term SR is unknown. Multiple organization indexes (OIs) have been previously developed to track the organization of AF during step-CA, however, with limited success. We report an adaptive method for tracking AF termination (AF-term) based on OIs characterizing the relationship between harmonic components of atrial activity from the surface ECG of AF activity. By computing their relative evolution during the last two steps preceding AF-term, we found that the performance of our OIs was superior to classical indices to track the efficiency of step-CA "en route" to AF-term. Our preliminary results suggest that the gradual synchronization between the fundamental and its first harmonic of AF activity appears as a promising parameter for predicting AF-term during step-CA.
Resumo:
AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
Resumo:
PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.
Resumo:
The purpose of this study was to evaluate a new method of measuring rolling resistance in treadmill cycling and to establish its sensitivity and reproducibility. One participant was asked to keep a bicycle in equilibrium on a treadmill without pedalling at a constant speed of 5.56 m x s(-1), which was held in place in the front by a dynamometer. For each condition, the method consisted of 11 measurements of the force required to hold the cycle at different treadmill slopes (0-10%, increment 1%). The coefficient of rolling resistance was calculated based on the forces applied to the bicycle in equilibrium. To test the sensitivity of the method, the bicycle was successively equipped with three tyre types (700 x 28, 700 x 23, 700 x 22) and inflation pressure was set at 150, 300, 600, 900, and 1100 kPa. To test the reproducibility of the method, a second experimenter repeated all measurements done with the 700 x 23 tyres. The method was sensitive enough to detect an effect of both tyre type and inflation pressure (P < 0.001: two-way ANOVA). The measurement of the coefficient of rolling resistance by two separate experimenters resulted in a small bias of 0.00029 (95% CI, -0.00011 to 0.00068). In conclusion, the new method is sensitive and reliable, as well as being simple and affordable.
Resumo:
Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.
Resumo:
A new method is used to estimate the volumes of sediments of glacial valleys. This method is based on the concept of sloping local base level and requires only a digital terrain model and the limits of the alluvial valleys as input data. The bedrock surface of the glacial valley is estimated by a progressive excavation of the digital elevation model (DEM) of the filled valley area. This is performed using an iterative routine that replaces the altitude of a point of the DEM by the mean value of its neighbors minus a fixed value. The result is a curved surface, quadratic in 2D. The bedrock surface of the Rhone Valley in Switzerland was estimated by this method using the free digital terrain model Shuttle Radar Topography Mission (SRTM) (~92 m resolution). The results obtained are in good agreement with the previous estimations based on seismic profiles and gravimetric modeling, with the exceptions of some particular locations. The results from the present method and those from the seismic interpretation are slightly different from the results of the gravimetric data. This discrepancy may result from the presence of large buried landslides in the bottom of the Rhone Valley.
Resumo:
The presence of the Etruscan shrew Suncus etruscus is hard to prove where its predator, the barn owl Tyto alba, is absent, because most live traps are not triggered by it. I therefore developed a new trapping method involving a feeding period of 1 week followed by one night of trapping using modified Trip Trap traps. I show here in detail how I caught four Etruscan shrews in 2010 with 24 traps in the Valley of Dora Baltea (Piemonte, Italy). In 2011, another 11 Etruscan shrews were caught in Piemonte and Lombardia, Italy, and Ticino, Switzerland. The proposed new method is useful for establishing the presence of the species.
Resumo:
OBJECTIVE: To describe a method to obtain a profile of the duration and intensity (speed) of walking periods over 24 hours in women under free-living conditions. DESIGN: A new method based on accelerometry was designed for analyzing walking activity. In order to take into account inter-individual variability of acceleration, an individual calibration process was used. Different experiments were performed to highlight the variability of acceleration vs walking speed relationship, to analyze the speed prediction accuracy of the method, and to test the assessment of walking distance and duration over 24-h. SUBJECTS: Twenty-eight women were studied (mean+/-s.d.) age: 39.3+/-8.9 y; body mass: 79.7+/-11.1 kg; body height: 162.9+/-5.4 cm; and body mass index (BMI) 30.0+/-3.8 kg/m(2). RESULTS: Accelerometer output was significantly correlated with speed during treadmill walking (r=0.95, P<0.01), and short unconstrained walks (r=0.86, P<0.01), although with a large inter-individual variation of the regression parameters. By using individual calibration, it was possible to predict walking speed on a standard urban circuit (predicted vs measured r=0.93, P<0.01, s.e.e.=0.51 km/h). In the free-living experiment, women spent on average 79.9+/-36.0 (range: 31.7-168.2) min/day in displacement activities, from which discontinuous short walking activities represented about 2/3 and continuous ones 1/3. Total walking distance averaged 2.1+/-1.2 (range: 0.4-4.7) km/day. It was performed at an average speed of 5.0+/-0.5 (range: 4.1-6.0) km/h. CONCLUSION: An accelerometer measuring the anteroposterior acceleration of the body can estimate walking speed together with the pattern, intensity and duration of daily walking activity.