190 resultados para multi-purpose trips

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The algorithmic approach to data modelling has developed rapidly these last years, in particular methods based on data mining and machine learning have been used in a growing number of applications. These methods follow a data-driven methodology, aiming at providing the best possible generalization and predictive abilities instead of concentrating on the properties of the data model. One of the most successful groups of such methods is known as Support Vector algorithms. Following the fruitful developments in applying Support Vector algorithms to spatial data, this paper introduces a new extension of the traditional support vector regression (SVR) algorithm. This extension allows for the simultaneous modelling of environmental data at several spatial scales. The joint influence of environmental processes presenting different patterns at different scales is here learned automatically from data, providing the optimum mixture of short and large-scale models. The method is adaptive to the spatial scale of the data. With this advantage, it can provide efficient means to model local anomalies that may typically arise in situations at an early phase of an environmental emergency. However, the proposed approach still requires some prior knowledge on the possible existence of such short-scale patterns. This is a possible limitation of the method for its implementation in early warning systems. The purpose of this paper is to present the multi-scale SVR model and to illustrate its use with an application to the mapping of Cs137 activity given the measurements taken in the region of Briansk following the Chernobyl accident.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: An optimal target for glucose control in ICU patients remains unclear. This prospective randomized controlled trial compared the effects on ICU mortality of intensive insulin therapy (IIT) with an intermediate glucose control. METHODS: Adult patients admitted to the 21 participating medico-surgical ICUs were randomized to group 1 (target BG 7.8-10.0 mmol/L) or to group 2 (target BG 4.4-6.1 mmol/L). RESULTS: While the required sample size was 1,750 per group, the trial was stopped early due to a high rate of unintended protocol violations. From 1,101 admissions, the outcomes of 542 patients assigned to group 1 and 536 of group 2 were analysed. The groups were well balanced. BG levels averaged in group 1 8.0 mmol/L (IQR 7.1-9.0) (median of all values) and 7.7 mmol/L (IQR 6.7-8.8) (median of morning BG) versus 6.5 mmol/L (IQR 6.0-7.2) and 6.1 mmol/L (IQR 5.5-6.8) for group 2 (p < 0.0001 for both comparisons). The percentage of patients treated with insulin averaged 66.2 and 96.3%, respectively. Proportion of time spent in target BG was similar, averaging 39.5% and 45.1% (median (IQR) 34.3 (18.5-50.0) and 39.3 (26.2-53.6)%) in the groups 1 and 2, respectively. The rate of hypoglycaemia was higher in the group 2 (8.7%) than in group 1 (2.7%, p < 0.0001). ICU mortality was similar in the two groups (15.3 vs. 17.2%). CONCLUSIONS: In this prematurely stopped and therefore underpowered study, there was a lack of clinical benefit of intensive insulin therapy (target 4.4-6.1 mmol/L), associated with an increased incidence of hypoglycaemia, as compared to a 7.8-10.0 mmol/L target. (ClinicalTrials.gov # NCT00107601, EUDRA-CT Number: 200400391440).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Significant progress has been made with regard to the quantitative integration of geophysical and hydrological data at the local scale for the purpose of improving predictions of groundwater flow and solute transport. However, extending corresponding approaches to the regional scale still represents one of the major challenges in the domain of hydrogeophysics. To address this problem, we have developed a regional-scale data integration methodology based on a two-step Bayesian sequential simulation approach. Our objective is to generate high-resolution stochastic realizations of the regional-scale hydraulic conductivity field in the common case where there exist spatially exhaustive but poorly resolved measurements of a related geophysical parameter, as well as highly resolved but spatially sparse collocated measurements of this geophysical parameter and the hydraulic conductivity. To integrate this multi-scale, multi-parameter database, we first link the low- and high-resolution geophysical data via a stochastic downscaling procedure. This is followed by relating the downscaled geophysical data to the high-resolution hydraulic conductivity distribution. After outlining the general methodology of the approach, we demonstrate its application to a realistic synthetic example where we consider as data high-resolution measurements of the hydraulic and electrical conductivities at a small number of borehole locations, as well as spatially exhaustive, low-resolution estimates of the electrical conductivity obtained from surface-based electrical resistivity tomography. The different stochastic realizations of the hydraulic conductivity field obtained using our procedure are validated by comparing their solute transport behaviour with that of the underlying ?true? hydraulic conductivity field. We find that, even in the presence of strong subsurface heterogeneity, our proposed procedure allows for the generation of faithful representations of the regional-scale hydraulic conductivity structure and reliable predictions of solute transport over long, regional-scale distances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:To describe the indications, the surgical procedure and the clinical outcome of MLAM in the treatment of non traumatic corneal perforations and descemetoceles . Methods:A prospective, non comparative, interventional case series of eight consecutive patients (mean age 59 years old, 6 men and 2 women) with non traumatic corneal perforations or descemetoceles.The surgery consisted in a MLAM transplantation of a cryopreservated human amniotic membrane. The series included: three active herpetic keratitis, one rosacea, one perforation of an hydrops, one cicatricial pemphigoid, one perforation after an abcess in a corneal graft and one perforation after protonbeamtherapy. The clinical outcome included: the follow-up, the integrity of the eye, corneal epithelialization, inflammation and neovascularization, and the integration of the MLAM. Stromal thickness was followed precisely with the slit lamp. A corneal graft was performed at one patient after the MLAM, allowing microscopic investigation of the removed MLAM integrated in the cornea. Results:The mean follow-up was 8.78 months (range 3.57 to 30.17). Amniotic membrane transplantation was successful and reduced inflammation in 7 patients out of 8 ,after one procedure.One patient who presented a large herpetic keratitis epithelial defect with corneal anaesthesia had his MLAM dissolved after two weeks with an aqueous leakage. Epithelium healed within 3 weeks above 7 MLAM and remained stable at 3 months in 7 out of 8 patients. MLAM opacification gradually disappeared over a few months, however, stromal layers filling in the corneal perforations or above the descemetoceles remained stable. Conclusions:MLAM transplantation is a safe, effective and useful technique to cure non traumatic corneal perforations and descemetoceles. It can be performed in emergency despite the presence of an active inflammation or infection. By facilitating epithelialization, reducing inflammation and neovascularization, it allows corneal surface reconstruction in patients with persistent epithelial defects and corneal melting that usually ends in a perforation. For full visual rehabilitation, a delayed penetrating keratoplasty is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To objectively characterize different heart tissues from functional and viability images provided by composite-strain-encoding (C-SENC) MRI. MATERIALS AND METHODS: C-SENC is a new MRI technique for simultaneously acquiring cardiac functional and viability images. In this work, an unsupervised multi-stage fuzzy clustering method is proposed to identify different heart tissues in the C-SENC images. The method is based on sequential application of the fuzzy c-means (FCM) and iterative self-organizing data (ISODATA) clustering algorithms. The proposed method is tested on simulated heart images and on images from nine patients with and without myocardial infarction (MI). The resulting clustered images are compared with MRI delayed-enhancement (DE) viability images for determining MI. Also, Bland-Altman analysis is conducted between the two methods. RESULTS: Normal myocardium, infarcted myocardium, and blood are correctly identified using the proposed method. The clustered images correctly identified 90 +/- 4% of the pixels defined as infarct in the DE images. In addition, 89 +/- 5% of the pixels defined as infarct in the clustered images were also defined as infarct in DE images. The Bland-Altman results show no bias between the two methods in identifying MI. CONCLUSION: The proposed technique allows for objectively identifying divergent heart tissues, which would be potentially important for clinical decision-making in patients with MI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The field of Connectomic research is growing rapidly, resulting from methodological advances in structural neuroimaging on many spatial scales. Especially progress in Diffusion MRI data acquisition and processing made available macroscopic structural connectivity maps in vivo through Connectome Mapping Pipelines (Hagmann et al, 2008) into so-called Connectomes (Hagmann 2005, Sporns et al, 2005). They exhibit both spatial and topological information that constrain functional imaging studies and are relevant in their interpretation. The need for a special-purpose software tool for both clinical researchers and neuroscientists to support investigations of such connectome data has grown. Methods: We developed the ConnectomeViewer, a powerful, extensible software tool for visualization and analysis in connectomic research. It uses the novel defined container-like Connectome File Format, specifying networks (GraphML), surfaces (Gifti), volumes (Nifti), track data (TrackVis) and metadata. Usage of Python as programming language allows it to by cross-platform and have access to a multitude of scientific libraries. Results: Using a flexible plugin architecture, it is possible to enhance functionality for specific purposes easily. Following features are already implemented: * Ready usage of libraries, e.g. for complex network analysis (NetworkX) and data plotting (Matplotlib). More brain connectivity measures will be implemented in a future release (Rubinov et al, 2009). * 3D View of networks with node positioning based on corresponding ROI surface patch. Other layouts possible. * Picking functionality to select nodes, select edges, get more node information (ConnectomeWiki), toggle surface representations * Interactive thresholding and modality selection of edge properties using filters * Arbitrary metadata can be stored for networks, thereby allowing e.g. group-based analysis or meta-analysis. * Python Shell for scripting. Application data is exposed and can be modified or used for further post-processing. * Visualization pipelines using filters and modules can be composed with Mayavi (Ramachandran et al, 2008). * Interface to TrackVis to visualize track data. Selected nodes are converted to ROIs for fiber filtering The Connectome Mapping Pipeline (Hagmann et al, 2008) processed 20 healthy subjects into an average Connectome dataset. The Figures show the ConnectomeViewer user interface using this dataset. Connections are shown that occur in all 20 subjects. The dataset is freely available from the homepage (connectomeviewer.org). Conclusions: The ConnectomeViewer is a cross-platform, open-source software tool that provides extensive visualization and analysis capabilities for connectomic research. It has a modular architecture, integrates relevant datatypes and is completely scriptable. Visit www.connectomics.org to get involved as user or developer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Intraoperative adverse events significantly influence morbidity and mortality of laparoscopic colorectal resections. Over an 11-year period, the changes of occurrence of such intraoperative adverse events were assessed in this study. METHODS: Analysis of 3,928 patients undergoing elective laparoscopic colorectal resection based on the prospective database of the Swiss Association of Laparoscopic and Thoracoscopic Surgery was performed. RESULTS: Overall, 377 intraoperative adverse events occurred in 329 patients (overall incidence of 8.4 %). Of 377 events, 163 (43 %) were surgical complications and 214 (57 %) were nonsurgical adverse events. Surgical complications were iatrogenic injury to solid organs (n = 63; incidence of 1.6 %), bleeding (n = 62; 1.6 %), lesion by puncture (n = 25; 0.6 %), and intraoperative anastomotic leakage (n = 13; 0.3 %). Of note, 11 % of intraoperative organ/puncture lesions requiring re-intervention were missed intraoperatively. Nonsurgical adverse events were problems with equipment (n = 127; 3.2 %), anesthetic problems (n = 30; 0.8 %), and various (n = 57; 1.5 %). Over time, the rate of intraoperative adverse events decreased, but not significantly. Bleeding complications significantly decreased (p = 0.015), and equipment problems increased (p = 0.036). However, the rate of adverse events requiring conversion significantly decreased with time (p < 0.001). Patients with an intraoperative adverse event had a significantly higher rate of postoperative local and general morbidity (41.2 and 32.9 % vs. 18.0 and 17.2 %, p < 0.001 and p < 0.001, respectively). CONCLUSIONS: Intraoperative surgical complications and adverse events in laparoscopic colorectal resections did not change significantly over time and are associated with an increased postoperative morbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Recurrent head and neck cancer is associated to a poor survival prognosis. A high toxicity rate is demonstrated when surgery and/or radiotherapy and/or chemotherapy are combined. Furthermore, the duration of treatment is often not ethically compatible with the expected survival (median survival<1year). Normal tissues tolerance limits the use of reirradiation and stereotactic body radiotherapy (SBRT) could offer precise irradiation while sparing healthy tissues. After completion of a feasibility study, results of a multicentric study (Lille, Nancy & Nice) using SBRT with cetuximab are reported. The aim of the study was to deliver non toxic short course SBRT (2weeks) in order to get the same local control as the one demonstrated with longer protocols. METHODS AND MATERIALS: Patients with inoperable recurrent, or new primary tumor in a previously irradiated area, were included (WHO<3). Reirradiation (RT) dose was 36Gy in six fractions of 6Gy to the 85% isodose line covering 95% of the PTV with 5 injections of concomitant cetuximab (CT). All patients had previous radiotherapy, 85% had previous surgery and 48% previous chemotherapy. RESULTS: Between 11/2007 and 08/2010, 60 were included (46 men and 14 women), 56 received CT+RT, 3 were not treated and 1 received only CT. Median age was 60 (42-87)) and all 56 patients had squamous carcinoma and received concomitant cetuximab. Mean time between previous radiotherapy and the start of SBRT was 38months. Cutaneous toxicity was observed for 41 patients. There was one toxic death from hemorrhage and denutrition. Median follow-up was 11.4months. At 3months, response rate was 58.4% (95% CI: 43.2-72.4%) and disease control rate was 91.7% (95% CI: 80.0-97.7%). The one-year OS rate was 47.5% (95% CI: 30.8-62.4). CONCLUSION: These results suggest that short SBRT with cetuximab is an effective salvage treatment with good response rate in this poor prognosis population with previously irradiated HNC. Treatment is feasible and, with appropriate care to limiting critical structure, acute toxicities are acceptable. This combination may be the reference treatment is this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Emergency room reading performances have been a point of interest in recent studies comparing radiologists to other physician groups. Our objective was to evaluate and compare the reading performances of radiologists and surgeons in an emergency room setting of non-traumatic abdominal CTs. Methods and materials: A total of ten readers representing four groups participated in this study: three senior radiologists and visceral surgeons, respectively, and two junior radiologists and surgeons, respectively. Each observer blindedly evaluated a total of 150 multi-slice acute abdominal CTs. CTs were chosen representing established proportions of acute abdomen pathologies in a Level I trauma centre from 2003 to 2005. Each answer was interpretated as right or wrong regarding pathology location, diagnosis and need for operation. Gold standard was the intraoperative result, and the clinical patient follow-up for non-operated patients. Significance was assumed at a p <.05 level. Results: Senior radiologists had a mean score of 2.38 ± 1.14, junior radiologists a score of 2.34 ± 1.14, whereas senior surgeons scored 2.07 ± 1.30 and junior surgeons 1.62 ± 1.42. No significant difference was found between the two radiologist groups, but results were significantly better for senior surgeons as compared to junior surgeons and better for the two radiologist groups as compared to each of the surgeon groups (all p <.05). Conclusion: Abdominal CT reading in an acute abdomen setting should continue to rely on an evaluation by a radiologist, whether senior or junior. Satisfying reading results can be achieved by senior visceral surgeons, but junior surgeons need more experience for a good reading performance.