19 resultados para molar tooth

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charcot-Marie-Tooth disease type 2A is an autosomal dominant axonal form of peripheral neuropathy caused by mutations in the mitofusin 2 gene. Mitofusin 2 encodes a mitochondrial outer membrane protein that participates in mitochondrial fusion in mammalian cells. How mutations in this protein lead to Charcot-Marie-Tooth disease type 2A pathophysiology remains unclear. We have generated a transgenic mouse expressing either a mutated (R94Q) or wild-type form of human mitofusin 2 in neurons to evaluate whether the R94Q mutation was sufficient for inducing a Charcot-Marie-Tooth disease type 2A phenotype. Only mice expressing mitofusin 2(R94Q) developed locomotor impairments and gait defects thus mimicking the Charcot-Marie-Tooth disease type 2A neuropathy. In these animals, the number of mitochondria per axon was significantly increased in the distal part of the sciatic nerve axons with a diameter smaller than 3.5 microm. Importantly, the analysis of R94Q transgenic animals also revealed an age-related shift in the size of myelinated axons leading to an over-representation of axons smaller than 3.5 microm. Together these data suggest a link between an increased number of mitochondria in axons and a shift in axonal size distribution in mitofusin 2(R94Q) transgenic animals that may contribute to their neurological phenotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charcot-Marie-Tooth disease (CMT) is a heterogeneous group of disorders of the peripheral nervous system, mainly characterized by distal muscle weakness and atrophy leading to motor handicap. With an estimated prevalence of 1 in 2,500, this condition is one of the most commonly inherited neurological disorders. Mutations in more than 30 genes affecting glial and/or neuronal functions have been associated with different forms of CMT leading to a substantial improvement in diagnostics of the disease and in the understanding of implicated pathophysiological mechanisms. However, recent data from systematic genetic screening performed in large cohorts of CMT patients indicated that molecular diagnosis could be established only in ∼50-70% of them, suggesting that additional genes are involved in this disease. In addition to providing an overview of genetic and functional data concerning various CMT forms, this review focuses on recent data generated through the use of highly parallel genetic technologies (SNP chips, sequence capture and next-generation DNA sequencing) in CMT families, and the current and future impact of these technologies on gene discovery and diagnostics of CMTs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mutations of the Ectodysplasin-A (EDA) gene are generally associated with the syndrome hypohidrotic ectodermal dysplasia (MIM 305100), but they can also manifest as selective, non-syndromic tooth agenesis (MIM300606). We have performed an in vitro functional analysis of six selective tooth agenesis-causing EDA mutations (one novel and five known) that are located in the C-terminal tumor necrosis factor homology domain of the protein. Our study reveals that expression, receptor binding or signaling capability of the mutant EDA1 proteins is only impaired in contrast to syndrome-causing mutations, which we have previously shown to abolish EDA1 expression, receptor binding or signaling. Our results support a model in which the development of the human dentition, especially of anterior teeth, requires the highest level of EDA-receptor signaling, whereas other ectodermal appendages, including posterior teeth, have less stringent requirements and form normally in response to EDA mutations with reduced activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with Charcot-Marie-Tooth neuropathy and gene targeting in mice revealed an essential role for the SH3TC2 gene in peripheral nerve myelination. SH3TC2 expression is restricted to Schwann cells in the peripheral nervous system, and the gene product, SH3TC2, localizes to the perinuclear recycling compartment. Here, we show that SH3TC2 interacts with the small guanosine triphosphatase Rab11, which is known to regulate the recycling of internalized membranes and receptors back to the cell surface. Results of protein binding studies and transferrin receptor trafficking are in line with a role of SH3TC2 as a Rab11 effector molecule. Consistent with a function of Rab11 in Schwann cell myelination, SH3TC2 mutations that cause neuropathy disrupt the SH3TC2/Rab11 interaction, and forced expression of dominant negative Rab11 strongly impairs myelin formation in vitro. Our data indicate that the SH3TC2/Rab11 interaction is relevant for peripheral nerve pathophysiology and place endosomal recycling on the list of cellular mechanisms involved in Schwann cell myelination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charcot-Marie-Tooth disease (CMT) comprises a clinically and genetically heterogeneous group of peripheral neuropathies characterized by progressive distal muscle weakness and atrophy, foot deformities and distal sensory loss. Following the analysis of two consanguineous families affected by a medium to late-onset recessive form of intermediate CMT, we identified overlapping regions of homozygosity on chromosome 1p36 with a combined maximum LOD score of 5.4. Molecular investigation of the genes from this region allowed identification of two homozygous mutations in PLEKHG5 that produce premature stop codons and are predicted to result in functional null alleles. Analysis of Plekhg5 in the mouse revealed that this gene is expressed in neurons and glial cells of the peripheral nervous system, and that knockout mice display reduced nerve conduction velocities that are comparable with those of affected individuals from both families. Interestingly, a homozygous PLEKHG5 missense mutation was previously reported in a recessive form of severe childhood onset lower motor neuron disease (LMND) leading to loss of the ability to walk and need for respiratory assistance. Together, these observations indicate that different mutations in PLEKHG5 lead to clinically diverse outcomes (intermediate CMT or LMND) affecting the function of neurons and glial cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain typical gait characteristics such as foot-drop and foot supination are well described in Charcot-Marie-Tooth disease. These are directly related to the primary disease and due to the weakness of ankle dorsiflexors and everters characteristic of this hereditary neuropathy. We analysed 16 subjects aged 8-52 years old (11 with type I, 5 with type II Charcot-Marie-Tooth disease) using three-dimensional gait analysis and identified kinematic features previously unreported. These patients showed a combination of tight tendo achillei, foot-drop, failure of plantar flexion and increased foot supination, but also presented with excessive internal rotation of the knee and/or tibia, knee hyperextension in stance, excessive external rotation at the hips and decreased hip adduction in stance (typical of a broad based gait). These proximal features could have been an adaptation to or consequence of the disrupted ankle and foot biomechanics, however a direct relation to the neuropathy is also possible since sub-normal muscle power was observed at the proximal levels in most subjects on both manual testing and kinetic analysis. Gait analysis is a useful tool in defining the characteristic gait of patients with Charcot-Marie-Tooth disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'ectodysplasine Al (EDA1 ou EDA), un ligand de la famille du TNF, et son récepteur EDAR favorisent le développement des poils, des dents et de plusieurs types de glandes. Chez l'humain, une déficience en EDA cause une dysplasie ectodermique liée à l'X, caractérisée par la genèse défectueuse des phanères. Les souris Tabby, déficientes en Eda, présentent des symptômes similaires. Nous démontrons que les souris Tabby sont en moyenne 7% plus légères que les contrôles au moment du sevrage. Ce phénotype ne dépend pas du génotype des petits, mais exclusivement de celui de la mère, suggérant que l'absence d'EDA perturbe la fonction mammaire. La glande mammaire se développe en plusieurs étapes, principalement à la puberté et pendant la grossesse. Nous avons généré des anticorps pour activer ou inhiber la signalisation d'EDAR. Les anticorps agonistes corrigent le développement de souris ou de chiens déficients en EDA, alors que les antagonistes provoquent une dysplasie ectodermique chez les souris saines. L'exposition répétée de souris Tabby aux anticorps agonistes après le sevrage accroît la taille et la fonction des glandes sébacées, démonstration pharmacologique qu'EDA contrôle l'homéostasie de la glande sébacée adulte. Ces outils seront utiles pour étudier la fonction d'EDA aux diverses étapes du développement de la glande mammaire. Fc-EDAl, un stimulateur d'EDAR, est en phase d'évaluation clinique. Nous avons montré que les structures dépendantes d'EDA qui se forment à différentes étapes du développement répondent à l'action du Fc-EDAl dans des fenêtres temporelles étroites ou larges. De plus, certaines structures peuvent être induites plusieurs jours après le début naturel de leur formation. Alors que la plupart des structures se forment suite à un seul jour d'activation d'EDAR, d'autre demandent un temps de stimulation plus long. La formation des dents est régulée par des signaux activateurs et inhibiteurs. Une forte stimulation d'EDAR spécifiquement appliquée aux deux premières molaires induit des signaux négatifs qui avortent la formation de la troisième molaire, alors qu'une forte stimulation donnée à la troisième molaire la rend hypertrophique tout en induisant parfois une quatrième molaire jamais observée chez les souris de type sauvage ou Tabby. EDA est donc un activateur important de la formation dentaire. Pris dans leur ensemble, ces résultats ont des implications pour la thérapie des dysplasies ectodermiques. - The TNF family ligand Ectodysplasin Al (EDA1 or EDA) and its receptor ED AR regulate embryonic development of hair, teeth and several types of glands. In humans, EDA mutations cause X-linked hypohidrotic ectodermal dysplasia (XLHED), a condition characterized by defective development of skin appendages. £da-deficient (Tabby) mice suffer from similar defects. We observed that Tabby pups at weaning were on average 7% smaller than WT controls, a phenotype that was curiously not linked to the genotype of pups, but to that of mothers, suggesting decreased mammary gland function in the absence of EDA. Mammary glands develop in several steps, most of which are post-natal. We generated monoclonal antibodies to block or activate EDAR signaling. Agonist antibodies rescued developmental defects when administered timely in £cfo-deficient mice and dogs, whereas blocking antibodies induced ectodermal dysplasia in WT mice. Agonist antibodies administered after weaning in £da-deficient mice for several months markedly increased both size and function of sebaceous glands, providing the first demonstration that pharmacological activation of the EDAR pathway in adults can correct important aspects of the dry skin phenotype. This also highlights a role for EDA1 in the homeostasis of adult sebaceous glands. These tools will be useful to study the function of EDA 1 at different stages of mammary gland development. Another EDAR agonist, Fc-EDAl, is currently evaluated in clinical trials. We found that EDA 1-dependent structures forming at different time points during development can respond to Fc-EDAl during time response windows that are narrow or wide. Also, some structures can be triggered up to several days after their normal time of induction. While most structures could be rescued by a single day of EDAR signaling, others required longer exposure times to form. Tooth formation is regulated by activating and inhibitory signals that impact one on the other. When strong EDAR signals were specifically given to the first two molars, overwhelming inhibitory signals completely inhibited formation of the third molar. In contrast, strong signals specifically given to the third molar induced hypertrophy of the later with occasional appearance of a fourth molar never observed in WT or £da-deficient mice. This clearly positions EDA as an important activating signal in tooth formation. Taken together, these results have implications for the therapy of ectodermal dysplasias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

tabby and downless mutant mice have apparently identical defects in teeth, hair and sweat glands. Recently, genes responsible for these spontaneous mutations have been identified. downless (Dl) encodes Edar, a novel member of the tumour necrosis factor (TNF) receptor family, containing the characteristic extracellular cysteine rich fold, a single transmembrane region and a death homology domain close to the C terminus. tabby (Ta) encodes ectodysplasin-A (Eda) a type II membrane protein of the TNF ligand family containing an internal collagen-like domain. As predicted by the similarity in adult mutant phenotype and the structure of the proteins, we demonstrate that Eda and Edar specifically interact in vitro. We have compared the expression pattern of Dl and Ta in mouse development, taking the tooth as our model system, and find that they are not expressed in adjacent cells as would have been expected. Teeth develop by a well recorded series of epithelial-mesenchymal interactions, similar to those in hair follicle and sweat gland development, the structures found to be defective in tabby and downless mice. We have analysed the downless mutant teeth in detail, and have traced the defect in cusp morphology back to initial defects in the structure of the tooth enamel knot at E13. Significantly, the defect is distinct from that of the tabby mutant. In the tabby mutant, there is a recognisable but small enamel knot, whereas in the downless mutant the knot is absent, but enamel knot cells are organised into a different shape, the enamel rope, showing altered expression of signalling factors (Shh, Fgf4, Bmp4 and Wnt10b). By adding a soluble form of Edar to tooth germs, we were able to mimic the tabby enamel knot phenotype, demonstrating the involvement of endogenous Eda in tooth development. We could not, however, reproduce the downless phenotype, suggesting the existence of yet another ligand or receptor, or of ligand-independent activation mechanisms for Edar. Changes in the structure of the enamel knot signalling centre in downless tooth germs provide functional data directly linking the enamel knot with tooth cusp morphogenesis. We also show that the Lef1 pathway, thought to be involved in these mutants, functions independently in a parallel pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the clinical fracture rate of crowns fabricated with the pressable, leucite-reinforced ceramic IPS Empress, and relate the results to the type of tooth restored. Materials and Methods: The database SCOPUS was searched for clinical studies involving full-coverage crowns made of IPS Empress. To assess the fracture rate of the crowns in relation to the type of restored tooth and study, Poisson regression analysis was used. Results: Seven clinical studies were identified involving 1,487 adhesively luted crowns (mean observation time: 4.5 +/- 1.7 years) and 81 crowns cemented with zinc-phosphate cement (mean observation time: 1.6 +/- 0.8 years). Fifty-seven of the adhesively luted crowns fractured (3.8%). The majority of fractures (62%) occurred between the third and sixth year after placement. There was no significant influence regarding the test center on fracture rate, but the restored tooth type played a significant role. The hazard rate (per year) for crowns was estimated to be 5 in every 1,000 crowns for incisors, 7 in every 1,000 crowns for premolars, 12 in every 1,000 crowns for canines, and 16 in every 1,000 crowns for molars. One molar crown in the zinc-phosphate group fractured after 1.2 years. Conclusion: Adhesively luted IPS Empress crowns showed a low fracture rate for incisors and premolars and a somewhat higher rate for molars and canines. The sample size of the conventionally luted crowns was too small and the observation period too short to draw meaningful conclusions. Int J Prosthodont 2010;23:129-133.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fossil bones and teeth of Late Pleistocene terrestrial mammals from Rhine River gravels (RS) and the North Sea (NS), that have been exposed to chemically and isotopically distinct diagenetic fluids (fresh water versus seawater), were investigated to study the effects of early diagenesis on biogenic apatite. Changes in phosphate oxygen isotopic composition (delta O-18(PO4)), nitrogen content (wt.% N) and rare earth element (REE) concentrations were measured along profiles within bones that have not been completely fossilized, and in skeletal tissues (bone, dentine, enamel) with different susceptibilities to diagenetic alteration. Early diagenetic changes of elemental and isotopic compositions of apatite in fossil bone are related to the loss of the stabilizing collagen matrix. The REE concentration is negatively correlated with the nitrogen content, and therefore the amount of collagen provides a sensitive proxy for early diagenetic alteration. REE patterns of RS and NS bones indicate initial fossilization in a fresh water fluid with similar REE compositions. Bones from both settings have nearly collagen-free, REE-, U-, F- and Sr-enriched altered outer rims, while the collagen-bearing bone compacta in the central part often display early diagenetic pyrite void-fillings. However, NS bones exposed to Holocene seawater have outer rim delta O-18(PO4) values that are 1.1 to 2.6 parts per thousand higher compared to the central part of the same bones (delta O-18(PO4) = 18.2 +/- 0.9 parts per thousand, n = 19). Surprisingly, even the collagen-rich bone compacta with low REE contents and apatite crystallinity seems altered, as NS tooth enamel (delta O-18(PO4) =15.0 +/- 0.3 parts per thousand, n=4) has about 3%. lower delta O-18(PO4) values, values that are also similar to those of enamel from RS teeth. Therefore, REE concentration, N content and apatite crystallinity are in this case only poor proxies for the alteration of delta O-18(PO4) values. Seawater exposure of a few years up to 8 kyr can change the delta O-18(PO4) values of the bone apatite by > 3 parts per thousand. Therefore, bones fossilized in marine settings must be treated with caution for palaeoclimatic reconstructions. However, enamel seems to preserve pristine delta O-18(PO4) values on this time scale. Using species-specific calibrations for modern mammals, a mean delta O-18(H2O) value can be reconstructed for Late Pleistocene mammalian drinking water of around -9.2 +/- 0.5 parts per thousand, which is similar to that of Late Pleistocene groundwater from central Europe. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: (1) To quantify wear of two different denture tooth materials in vivo with two study designs, (2) to relate tooth variables to vertical loss. METHODS: Two different denture tooth materials had been used (experimental material=test; DCL=control). In study 1 (split-mouth, 6 test centers) 60 subjects received complete dentures, in study 2 (two-arm, 1 test center) 29 subjects. In study 1 the mandibular dentures were supported by implants in 33% of the subjects, in study 2 only in 3% of the subjects. Impressions of the dentures were taken and poured with improved stone at baseline and after 6, 12, 18 and 24 months. Each operator evaluated the wear subjectively. Wear analysis was carried out with a laser scanning device. Maximal vertical loss of the attrition zones was calculated for each tooth cusp and tooth. A mixed linear model was used to statistically analyse the logarithmically transformed wear data. RESULTS: Due to drop-outs and unmatchable casts, only 47 subjects of study 1 and 14 of study 2 completed the 2-year recall. Overall, 75% of all teeth present could be analysed. There was no statistically difference in the overall wear between the test and control material for either study 1 or study 2. The relative increase in wear over time was similar in both study designs. However, a strong subject effect and center effect were observed. The fixed factors included in the model (time, tooth, center, etc.) accounted for 43% of the variability, whereas the random subject effect accounted for another 30% of the variability, leaving about 28% of unexplained variability. More wear was consistently recorded in the maxillary teeth compared to the mandibular teeth and in the first molar teeth compared to the premolar teeth and the second molars. Likewise, the supporting cusps showed more wear than the non-supporting cusps. The amount of wear did not depend on whether or not the lower dentures were supported by implants. The subjective wear was correct in about 67% of the cases if it is postulated that a wear difference of 100μm should be subjectively detectable. SIGNIFICANCE: The clinical wear of denture teeth is highly variable with a strong patient effect. More wear can be expected in maxillary denture teeth compared to mandibular teeth, first molars compared to premolars and supported cusps compared to non-supported cusps. Laboratory data on the wear of denture tooth materials may not be confirmed in well-structured clinical trials probably due to the large inter-individual variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Cette étude a démontré l'effet individuel sur la coagulation sanguine humaine des deux principales caractéristiques de la molécule d'hydroxyéthylamidon (HES) : la substitution molaire et le rapport C2/C6. L'analyse par thrombélastographe (TEG®) indique que la molécule de HES dont la substitution molaire est de 0.42 et le rapport C2/C6 de 2.7 a le moins d'effet sur la coagulation sanguine chez l'être humain. Objectifs de l'étude Le développement d'hydroxyéthylamidons (HES) qui ont à la fois peu d'impact sur la coagulation sanguine et une longue persistance intravasculaire est d'un grand intérêt clinique. Une précédente étude in vitro a démontré qu'une solution de HES de haut poids moléculaire et de bas degré de substitution molaire ne compromettait pas plus la coagulation sanguine qu'une solution HES de poids moléculaire moyen (1). La présente étude examine l'effet individuel de la substitution molaire et du rapport C2/C6 d'une solution de HES de haut poids moléculaire (700 kDa) sur la coagulation sanguine. Matériel et méthode Nous avons prélevé du sang chez 30 adultes en bonne santé; le sang a été mélangé avec 6 solutions de HES qui diffèrent par leur degré de substitution molaire (0.42 et 0.51) et leur rapport C2/C6 (2.7, 7 et 14) à trois degrés de dilution : 20%, 40% et 60%. Les échantillons ont ensuite été analysés par thrombélastographe. Les données ont été étudiées par analyse de variance à trois voies pour mesures répétées sur une voie (dilution). Résultats Plus la substitution molaire est élevée, plus la coagulation sanguine est compromise et ce concernant tous les paramètres du TEG® (tous les p sont < à 0.05). La solution HES avec le rapport C2/C6 le plus bas a l'effet le moins prononcé sur le temps r (p<0.001), l'angle α (p=0.003) et l'Index de Coagulation CI (p<0.001) ; on n'a pas observé d'effet sur le temps k (p=0.513) et l'amplitude maximale (p=0.699) concernant ce paramètre. Conclusion L'analyse par thrombélastographe révèle qu'une molécule de HES avec une substitution molaire de 0.42 et un rapport C2/C6 de 2.7 a un effet minimal sur la coagulation sanguine humaine in vitro.