95 resultados para modified ground plane

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cross-hole radar tomography is a useful tool for mapping shallow subsurface electrical properties viz. dielectric permittivity and electrical conductivity. Common practice is to invert cross-hole radar data with ray-based tomographic algorithms using first arrival traveltimes and first cycle amplitudes. However, the resolution of conventional standard ray-based inversion schemes for cross-hole ground-penetrating radar (GPR) is limited because only a fraction of the information contained in the radar data is used. The resolution can be improved significantly by using a full-waveform inversion that considers the entire waveform, or significant parts thereof. A recently developed 2D time-domain vectorial full-waveform crosshole radar inversion code has been modified in the present study by allowing optimized acquisition setups that reduce the acquisition time and computational costs significantly. This is achieved by minimizing the number of transmitter points and maximizing the number of receiver positions. The improved algorithm was employed to invert cross-hole GPR data acquired within a gravel aquifer (4-10 m depth) in the Thur valley, Switzerland. The simulated traces of the final model obtained by the full-waveform inversion fit the observed traces very well in the lower part of the section and reasonably well in the upper part of the section. Compared to the ray-based inversion, the results from the full-waveform inversion show significantly higher resolution images. At either side, 2.5 m distance away from the cross-hole plane, borehole logs were acquired. There is a good correspondence between the conductivity tomograms and the natural gamma logs at the boundary of the gravel layer and the underlying lacustrine clay deposits. Using existing petrophysical models, the inversion results and neutron-neutron logs are converted to porosity. Without any additional calibration, the values obtained for the converted neutron-neutron logs and permittivity results are very close and similar vertical variations can be observed. The full-waveform inversion provides in both cases additional information about the subsurface. Due to the presence of the water table and associated refracted/reflected waves, the upper traces are not well fitted and the upper 2 m in the permittivity and conductivity tomograms are not reliably reconstructed because the unsaturated zone is not incorporated into the inversion domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Adaptations to Internal (IR) and external (ER) rotator shoulder muscles improving overhead throwing kinematics could lead to muscular strength imbalances and be considered an intrinsic risk factor for shoulder injury, as well as modified shoulder range of motion (RoM). OBJECTIVE: To establish profiles of internal and external rotation RoM and isokinetic IR and ER strength in adolescent- and national-level javelin throwers. METHODS: Fourteen healthy subjects were included in this preliminary cross-sectional study, 7 javelin throwers (JTG) and 7 nonathletes (CG). Passive internal and external rotation RoM were measured at 90 degrees of shoulder abduction. Isokinetic strength of dominant and non-dominant IR and ER was evaluated during concentric (60, 120 and 240 degrees/s) and eccentric (60 degrees/s) contractions by Con-Trex (R) dynamometer with the subject in a seated position with 45 degrees of shoulder abduction in the scapular plane. RESULTS: We reported significantly lower internal rotation and significantly higher external rotation RoM in JTG than in CG. Concentric and eccentric IR and ER strength were significantly higher for the dominant shoulder side in JTG (P < 0.05), without significant differences in ER/IR ratios. CONCLUSIONS: The main finding of this preliminary study confirmed static and dynamic shoulder stabilizer adaptations due to javelin throw practice in a population of adolescent- and national-level javelin throwers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Tissue engineering methods can be applied to regenerate diseased, or congenitally missing, urinary tract tissues. Urinary tract tissue cell cultures must be established in vitro and adequate matrices, acting as cell carriers, must be developed. Although degradable and nondegradable polymer matrices offer adequate mechanical stability, they are not optimal for cell adherence and growth. To overcome this problem, extracellular matrix proteins, permitting cell adhesion and regulation of cell proliferation and differentiation, can be adsorbed to the surface-modified polymer. METHODS: In this study, nondegradable polymer films, poly(ethylene terephthalate), were used as an experimental model. Films were modified by graft polymerization of acrylic acid to subsequently allow collagen type I and III immobilization. The following adhesion, proliferation of human urothelial cells, and induction of their stratification were analyzed. RESULTS: Collagen adsorption on 0.2 microg/cm2 poly(acrylic acid)-grafted polymer films rendered the matrix apt for human urothelial cell adhesion and proliferation. Furthermore, stratification of urothelial cells was demonstrated on these surface-modified matrices. CONCLUSIONS: These results have shown that surface-modified polymer matrices can be used to act as cell carriers for cultured human urothelial cells. Such a cell-matrix construct could be applied in reparative surgery of the urinary tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to present a multitechnique approach to define the geometry, the kinematics, and the failure mechanism of a retrogressive large landslide (upper part of the La Valette landslide, South French Alps) by the combination of airborne and terrestrial laser scanning data and ground-based seismic tomography data. The advantage of combining different methods is to constrain the geometrical and failure mechanism models by integrating different sources of information. Because of an important point density at the ground surface (4. 1 points m?2), a small laser footprint (0.09 m) and an accurate three-dimensional positioning (0.07 m), airborne laser scanning data are adapted as a source of information to analyze morphological structures at the surface. Seismic tomography surveys (P-wave and S-wave velocities) may highlight the presence of low-seismic-velocity zones that characterize the presence of dense fracture networks at the subsurface. The surface displacements measured from the terrestrial laser scanning data over a period of 2 years (May 2008?May 2010) allow one to quantify the landslide activity at the direct vicinity of the identified discontinuities. An important subsidence of the crown area with an average subsidence rate of 3.07 m?year?1 is determined. The displacement directions indicate that the retrogression is controlled structurally by the preexisting discontinuities. A conceptual structural model is proposed to explain the failure mechanism and the retrogressive evolution of the main scarp. Uphill, the crown area is affected by planar sliding included in a deeper wedge failure system constrained by two preexisting fractures. Downhill, the landslide body acts as a buttress for the upper part. Consequently, the progression of the landslide body downhill allows the development of dip-slope failures, and coherent blocks start sliding along planar discontinuities. The volume of the failed mass in the crown area is estimated at 500,000 m3 with the sloping local base level method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantitative assessment of the age-dependent number of neuritic plaques is essential for the diagnosis of Alzheimer type dementia. This study reports the superiority of a modified Hortega-Globus stain compared to Bielschowsky and Bodian stains applied to samples obtained from ten brains of patients with a clinical history of progressive dementia. In two of ten cases only the modified Hortega-Globus stain allowed confirmation of the diagnosis of senile dementia of the Alzheimer type (SDAT). The counts of neuritic plaques in sections stained by other methods were not sufficient to establish the histological diagnosis of SDAT. These results indicate that the choice of the most sensitive staining method is critical for the correct histopathologic diagnosis of the Alzheimer type dementia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHESEBUTLe but de cette étude est de suivre prospectivement les résultats d'une sclérectomie profonde (SP) modifiée en utilisant le tube Ex-PRJESS LR-50, associée à une phacoémulsification avec implantation d'une lentille intraoculaire (LIO), dans la chirurgie combinée du glaucome et de la cataracte.METHODENous avons inclus dans l'étude 24 yeux de 24 patients présentant un glaucome médicalement non contrôlé et une cataracte justifiant son ablation.Une phacoémulsification avec implantation d'une LIO est effectuée. Puis le tube Ex-PRESS LR-50 est inséré au niveau du canal de Schlemm, dans la chambre antérieure, sous un volet scléral. Une SP postérieure partielle est ensuite pratiquée afin de créer une bulle de filtration intrasclérale.Le taux de succès complet a été défini par une pression intraoculaire (PIO) <18 mmHg sans traitement et le taux de succès relatif par une PIO <18 mmHg avec ou sans traitement. En cas de fibrose ou de kyste de la bulle de filtration, une injection sous-conjonctivale d'une solution de Mitomycin C à 0.02% est réalisée, avec ou sans needling.RESULTATSLe suivi moyen était de 40.1±10.8 [moyenne±DS] mois. En préopératoire, la PIO se situait à 18.1 ±5.3 mmHg; la meilleure acuité visuelle corrigée (MAVC) était mesurée à 0.6±0.3 (échelle de Snellen) et le nombre de médicaments hypotenseurs oculaires était de 2.3±1.1. La PIO a diminué de 25.4% à 24 mois et de 27.0% à 48 mois. A 24 mois, 19 patients (86.3%) avaient une MAVC supérieure ou égal à 0.5, et à 48 mois la MAVC était mesurée à 0.7±0.3. Lors de la dernière visite, le nombre moyen de médicaments se situait à 0.6±0.8 (p<0.05). Des injections sous conjonctivales d'une solution de Mitomycin C à 0.02% ont été nécessaires dans 5 yeux. Aucune érosion conjonctivale n'a été constatée. Deux complications majeures ont été observées. Une endophtalmie, deux jours après l'intervention chirurgicale avec phtisis secondaire du globe oculaire. Une obstruction du tube Ex-PRESS LR-50 par de la fibrine, ayant justifié son ablation avec SP classique en un autre site.CONCLUSIONLe tube Ex-PRESS LR-50 inséré dans la chambre antérieure avec une SP modifiée réduit efficacement la PIO dans la chirurgie combinée du glaucome et prévient l'érosion conjonctivale, une complication importante lorsque l'implant n'est pas couvert par un volet scléral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Morris water maze (MWM) task, proprioceptive information is likely to have a poor accuracy due to movement inertia. Hence, in this condition, dynamic visual information providing information on linear and angular acceleration would play a critical role in spatial navigation. To investigate this assumption we compared rat's spatial performance in the MWM and in the homing hole board (HB) tasks using a 1.5 Hz stroboscopic illumination. In the MWM, rats trained in the stroboscopic condition needed more time than those trained in a continuous light condition to reach the hidden platform. They expressed also little accuracy during the probe trial. In the HB task, in contrast, place learning remained unaffected by the stroboscopic light condition. The deficit in the MWM was thus complete, affecting both escape latency and discrimination of the reinforced area, and was thus task specific. This dissociation confirms that dynamic visual information is crucial to spatial navigation in the MWM whereas spatial navigation on solid ground is mediated by a multisensory integration, and thus less dependent on visual information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of biocontrol strain Pseudomonas fluorescens CHA0 and of its genetically modified, antibiotic-overproducing derivative CHA0/pME3424 on a reconstructed population of the plant-beneficial Sinorhizobium meliloti bacteria was assessed in gnotobiotic systems. In sterile soil, the final density of the reconstructed S. meliloti population decreased by more than one order of magnitude in the presence of either of the Pseudomonas strains when compared to a control without addition of P. fluorescens. Moreover, there was a change in the proportion of each individual S. meliloti strain within the population. Plant tests also revealed changes in the nodulating S. meliloti population in the presence of strains CHA0 or CHA0/pME3424. In both treatments one S. meliloti strain, f43, was significantly reduced in its root nodule occupancy. Analysis of alfalfa yields showed a slight but statistically significant increase in shoot dry weight when strain CHA0 was added to the reconstructed S. meliloti population whereas no such effect was observed with CHA0/pME3424.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to compare VO2 kinetics during constant power cycle exercise measured using a conventional facemask (CM) or a respiratory snorkel (RS) designed for breath-by-breath analysis in swimming. METHODS: VO2 kinetics parameters-obtained using CM or RS, in randomized counterbalanced order-were compared in 10 trained triathletes performing two submaximal heavy-intensity cycling square-wave transitions. These VO2 kinetics parameters (ie, time delay: td1, td2; time constant: τ1, τ2; amplitude: A1, A2, for the primary phase and slow component, respectively) were modeled using a double exponential function. In the case of the RS data, this model incorporated an individually determined snorkel delay (ISD). RESULTS: Only td1 (8.9 ± 3.0 vs 13.8 ± 1.8 s, P < .01) differed between CM and RS, whereas all other parameters were not different (τ1 = 24.7 ± 7.6 vs 21.1 ± 6.3 s; A1 = 39.4 ± 5.3 vs 36.8 ± 5.1 mL x min(-1) x kg(-1); td2 = 107.5 ± 87.4 vs 183.5 ± 75.9 s; A2' (relevant slow component amplitude) = 2.6 ± 2.4 vs 3.1 ± 2.6 mL x min(-1) x kg(-1) for CM and RS, respectively). CONCLUSIONS: Although there can be a small mixture of breaths allowed by the volume of the snorkel in the transition to exercise, this does not appear to significantly influence the results. Therefore, given the use of an ISD, the RS is a valid instrument for the determination of VO2 kinetics within submaximal exercise.