26 resultados para mismatched beams

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D dose reconstruction is a verification of the delivered absorbed dose. Our aim was to describe and evaluate a 3D dose reconstruction method applied to phantoms in the context of narrow beams. A solid water phantom and a phantom containing a bone-equivalent material were irradiated on a 6 MV linac. The transmitted dose was measured by using one array of a 2D ion chamber detector. The dose reconstruction was obtained by an iterative algorithm. A phantom set-up error and organ interfraction motion were simulated to test the algorithm sensitivity. In all configurations convergence was obtained within three iterations. A local reconstructed dose agreement of at least 3% / 3mm with respect to the planned dose was obtained, except in a few points of the penumbra. The reconstructed primary fluences were consistent with the planned ones, which validates the whole reconstruction process. The results validate our method in a simple geometry and for narrow beams. The method is sensitive to a set-up error of a heterogeneous phantom and interfraction heterogeneous organ motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Converging evidence favors an abnormal susceptibility to oxidative stress in schizophrenia. Decreased levels of glutathione (GSH), the major cellular antioxidant and redox regulator, was observed in cerebrospinal-fluid and prefrontal cortex of patients. Importantly, abnormal GSH synthesis of genetic origin was observed: Two case-control studies showed an association with a GAG trinucleotide repeat (TNR) polymorphism in the GSH key synthesizing enzyme glutamate-cysteine-ligase (GCL) catalytic subunit (GCLC) gene. The most common TNR genotype 7/7 was more frequent in controls, whereas the rarest TNR genotype 8/8 was three times more frequent in patients. The disease associated genotypes (35% of patients) correlated with decreased GCLC protein, GCL activity and GSH content. Similar GSH system anomalies were observed in early psychosis patients. Such redox dysregulation combined with environmental stressors at specific developmental stages could underlie structural and functional connectivity anomalies. In pharmacological and knock-out (KO) models, GSH deficit induces anomalies analogous to those reported in patients. (a) morphology: spine density and GABA-parvalbumine immunoreactivity (PV-I) were decreased in anterior cingulate cortex. KO mice showed delayed cortical PV-I at PD10. This effect is exacerbated in mice with increased DA from PD5-10. KO mice exhibit cortical impairment in myelin and perineuronal net known to modulate PV connectivity. (b) physiology: In cultured neurons, NMDA response are depressed by D2 activation. In hippocampus, NMDA-dependent synaptic plasticity is impaired and kainate induced g-oscillations are reduced in parallel to PV-I. (c) cognition: low GSH models show increased sensitivity to stress, hyperactivity, abnormal object recognition, olfactory integration and social behavior. In a clinical study, GSH precursor N-acetyl cysteine (NAC) as add on therapy, improves the negative symptoms and decreases the side effects of antipsychotics. In an auditory oddball paradigm, NAC improves the mismatched negativity, an evoked potential related to pre-attention and to NMDA receptors function. In summary, clinical and experimental evidence converge to demonstrate that a genetically induced dysregulation of GSH synthesis combined with environmental insults in early development represent a major risk factor contributing to the development of schizophrenia Conclusion Based on these data, we proposed a model for PSIP1 promoter activity involving a complex interplay between yet undefined regulatory elements to modulate gene expression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiotherapy is a widely used treatment option in cancer. However, recent evidence suggests that doses of ionizing radiation (IR) delivered inside the tumor target volume, during fractionated radiotherapy, can promote tumor invasion and metastasis. Furthermore, the tissues that surround the tumor area are also exposed to low doses of IR that are lower than those delivered inside the tumor mass, because external radiotherapy is delivered to the tumor through multiple radiation beams, in order to prevent damage of organs at risk. The biological effects of these low doses of IR on the healthy tissue surrounding the tumor area, and in particular on the vasculature remain largely to be determined. We found that doses of IR lower or equal to 0.8 Gy enhance endothelial cell migration without impinging on cell proliferation or survival. Moreover, we show that low-dose IR induces a rapid phosphorylation of several endothelial cell proteins, including the Vascular Endothelial Growth Factor (VEGF) Receptor-2 and induces VEGF production in hypoxia mimicking conditions. By activating the VEGF Receptor-2, low-dose IR enhances endothelial cell migration and prevents endothelial cell death promoted by an anti-angiogenic drug, bevacizumab. In addition, we observed that low-dose IR accelerates embryonic angiogenic sprouting during zebrafish development and promotes adult angiogenesis during zebrafish fin regeneration and in the murine Matrigel assay. Using murine experimental models of leukemia and orthotopic breast cancer, we show that low-dose IR promotes tumor growth and metastasis and that these effects were prevented by the administration of a VEGF receptor-tyrosine kinase inhibitor immediately before IR exposure. These findings demonstrate a new mechanism to the understanding of the potential pro-metastatic effect of IR and may provide a new rationale basis to the improvement of current radiotherapy protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Allogeneic MHC-incompatible organ or cell grafts are usually promptly rejected by immunocompetent hosts. Here we tested allogeneic beta-islet cell graft acceptance by immune or naive C57BL/6 mice rendered diabetic with streptozotocin (STZ). Fully MHC-mismatched insulin-producing growth-regulated beta-islet cells were transplanted under the kidney capsule or s.c. Although previously or simultaneously primed mice rejected grafts, STZ-treated diabetic mice accepted islet cell grafts, and hyperglycemia was corrected within 2-4 weeks in absence of conventional immunosuppression. Allogeneic grafts that controlled hyperglycemia expressed MHC antigens, were not rejected for >100 days, and resisted a challenge by allogeneic skin grafts or multiple injections of allogeneic cells. Importantly, the skin grafts were rejected in a primary fashion by the grafted and corrected host, indicating neither tolerization nor priming. Such strictly extralymphatic cell grafts that are immunologically largely ignored should be applicable clinically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To achieve the goal of sustained donor-specifi c transplantation (Tx) tolerance, research efforts are now focusing on therapies based on specifi c cell subsets with regulatory properties. We and others have previously highlighted the therapeutic potential of naturally occurring CD4+CD25+Foxp3+ regulatory T cells (nTreg) in promoting long-term graft acceptance. Using more stringent experimental Tx models, we were however confronted to limitations. Indeed, while the transfer of antigenspecifi c nTreg promoted long-term MHC-mismatched skin allograft acceptance in lymphopenic mice in the absence of any immunosuppressive drug, allograft survival was only slightly prolonged when nTreg were transferred alone into non-lymphopenic mice. This suggested that in more stringent conditions, adjuvant therapies may be needed to effectively control alloreactive T cells (Teff). Whether and how the expansion of the Treg pool could be best combined with current immunosuppressive regimens in clinical settings remains to be defi ned. In this study, we have used in vitro assays and an in vivo skin Tx model to investigate the effects of various immunosuppressive drugs on the survival, proliferation and effector function of Teff and nTreg in response to alloantigens. Teff proliferation was inhibited in a dose-dependent manner by rapamycin and cyclosporine A, while anti-CD154 mAb only marginally affected Teff survival, proliferation and effector fucntion in vitro. Rapamycin promoted apoptosis of Teff as compared to nTreg that were more resistant in the presence of IL-2. In vivo, the transfer and/or expansion of Treg could be advantageously combined with rapamycin and anti-CD154 mAb treatment to signifi cantly prolong MHC-mismatched skin allografts survival in non-lymphopenic recipients. Taken together our data indicate that immunosuppressive drugs differentially target T-cell subsets and that some regimens could promote Treg expansion while controlling the Teff pool in response to alloantigens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many experimental models, CD4+CD25+Foxp3+ regulatory T cells (nTreg) have been identifi ed as key players in promoting peripheral transplantation (Tx) tolerance. We have been focusing on therapies based on antigen-specifi c nTreg that can control effector T cells (Teff) and prevent allograft rejection. The use of nTreg in immunotherapeutic protocols for solid organ Tx is however limited by their overall low numbers as well as the low precursor frequency of alloantigen cross-reactive nTreg expected to be found in a normal individual. Moreover, although we previously described robust protocols to generate and expand antigen-specifi c nTreg in vitro, the process requires careful selection of highly pure nTreg and cumbersome ex-vivo manipulations, rendering this strategy not easily applicable in clinical solid organ Tx. In this study, we aimed to expand Treg directly in vivo and determine their suppressive function, effi cacy and stability in promoting donor-specifi c tolerance in a stringent murine Tx model. Our data suggest that IL-2-based therapies lead to a signifi cant increase of Treg in vivo. The expanded Treg suppressed Teff proliferation (albeit slightly less effi ciently than nTreg isolated from control mice) and allowed prolonged graft survival of major MHC-mismatched skin grafts in wild-type non-lymphopenic recipients. The expanded Treg alone were however not suffi cient to induce tolerance in stringent experimental conditions. Rapamycin reduced the frequency of Teff but did not impede expansion of Treg. Pro-infl ammatory stimuli hindered the expansion of Treg and resulted in an increase in the frequency of CD4+IFN-γ+ and CD4+IL17+ T cells. We propose that IL-2-based treatments would be an effi cient method for expanding functional Treg in vivo without affecting other immune cell populations, thereby favorably shifting the pool of alloreactive T cells towards regulation in response to an allograft. However, we also highlight some potential limitations of Treg expansion such as concomitant infl ammatory events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Establishment of mixed chimerism through transplantation of allogeneic donor bone marrow (BM) into sufficiently conditioned recipients is an effective experimental approach for the induction of transplantation tolerance. Clinical translation, however, is impeded by the lack of feasible protocols devoid of cytoreductive conditioning (i.e. irradiation and cytotoxic drugs/mAbs). The therapeutic application of regulatory T cells (Tregs) prolongs allograft survival in experimental models, but appears insufficient to induce robust tolerance on its own. We thus investigated whether mixed chimerism and tolerance could be realized without the need for cytoreductive treatment by combining Treg therapy with BM transplantation (BMT). Polyclonal recipient Tregs were cotransplanted with a moderate dose of fully mismatched allogeneic donor BM into recipients conditioned solely with short-course costimulation blockade and rapamycin. This combination treatment led to long-term multilineage chimerism and donor-specific skin graft tolerance. Chimeras also developed humoral and in vitro tolerance. Both deletional and nondeletional mechanisms contributed to maintenance of tolerance. All tested populations of polyclonal Tregs (FoxP3-transduced Tregs, natural Tregs and TGF-beta induced Tregs) were effective in this setting. Thus, Treg therapy achieves mixed chimerism and tolerance without cytoreductive recipient treatment, thereby eliminating a major toxic element impeding clinical translation of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Early assessment of radiotherapy (RT) quality in the ongoing EORTC trial comparing primary temozolomide versus RT in low-grade gliomas. MATERIALS AND METHODS: RT plans provided for dummy cases were evaluated and compared against expert plans. We analysed: (1) tumour and organs-at-risk delineation, (2) geometric and dosimetric characteristics, (3) planning parameters, compliance with dose prescription and Dmax for OAR (4) indices: RTOG conformity index (CI), coverage factor (CF), tissue protection factor (PF); conformity number (CN = PF x CF); dose homogeneity in PTV (U). RESULTS: Forty-one RT plans were evaluated. Only two (5%) centres were requested to repeat CTV-PTV delineations. Three (7%) plans had a significant under-dosage and dose homogeneity in one deviated > 10%. Dose distribution was good with mean values of 1.5, 1, 0.68, and 0.68 (ideal values = 1) for CI, CF, PF, and CN, respectively. CI and CN strongly correlated with PF and they correlated with PTV. Planning with more beams seems to increase PTV(Dmin), improving CF. U correlated with PTV(Dmax). CONCLUSION: Preliminary results of the dummy run procedure indicate that most centres conformed to protocol requirements. To quantify plan quality we recommend systematic calculation of U and either CI or CN, both of which measure the amount of irradiated normal brain tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Allogeneic bone marrow donors can be incompatible at different levels. Even HLA-identical pairs will be still incompatible for numerous minor histocompatibility antigens (mHag). Nevertheless, some incompatibilities are found to be associated with an increased risk of graft-versus-host disease (GVHD), which could be related to the way the immune system recognizes these antigens. METHODS: We determined the specificity of cytotoxic T-cell clones isolated during acute GVHD or during bone marrow graft rejection in patients (n=14) transplanted with marrow from donors who were histoincompatible for different minor and/or major histocompatibility antigens. RESULTS: We found a clear hierarchy among the different types of histoincompatibilities. In three combinations mismatched for a class I allele, all 27 clones isolated during GVHD were specific for the incompatible HLA molecule. In the 11 class I-identical combinations, 14 different mHags were recognized. The mHag HA-1, known to have a significant impact on the development of GVHD, was recognized in the two HA-1-incompatible combinations. In one of these combinations, which was sex mismatched, all 56 clones analyzed were directed against HA-1, demonstrating the dominance of this mHag. In the four HA-1-compatible, sex-mismatched combinations, the anti-H-Y response was directed against one immunodominant epitope rather than against multiple Y-chromosome-encoded epitopes. All male specific cytotoxic T lymphocytes (n=15) recognized the same high-performance liquid chromatography-purified peptide fraction presented by T2 cells. Moreover, all cytotoxic T lymphocytes tested (n=6) were specific for the SMCY-derived peptide FIDSYICQV, originally described as being the H-Y epitope recognized in the context of HLA-A*0201. CONCLUSIONS: Some histocompatibility antigens are recognized in an immunodominant fashion and will therefore be recognized in the majority of mismatched combinations. Only for such antigens, correlations between mismatches and the occurrence of GVHD or graft rejections will be found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While the influence of HLA-AB and -DRB1 matching on the outcome of bone marrow transplantation (BMT) with unrelated donors is clear, the evaluation of HLA-C has been hampered by its poor serological definition. Because the low resolution of standard HLA-C typing could explain the significant number of positive cytotoxic T lymphocyte precursor frequency (CTLpf) tests found among HLA-AB-subtype, DRB1/B3/B5-subtype matched patient/donor pairs, we have identified by sequencing the incompatibilities recognized by CD8+ CTL clones obtained from such positive CTLpf tests. In most cases the target molecules were HLA-C antigens that had escaped detection by serology (e.g. Cw*1601, 1502 or 0702). Direct recognition of HLA-C by a CTL clone was demonstrated by lysis of the HLA class I-negative 721.221 cell line transfected with Cw*1601 cDNA. Because of the functional importance of Cw polymorphism, a PCR-SSO oligotyping procedure was set up allowing the resolution of 29 Cw alleles. Oligotyping of a panel of 382 individuals (including 101 patients and their 272 potential unrelated donors, 5 related donors and 4 platelet donors) allowed to determine HLA-C and HLA A-B-Cw-DRB1 allelic frequencies, as well as a number of A-Cw, B-Cw, and DRB1-Cw associations. Two new HLA-Cw alleles (Cw*02023 and Cw*0707) were identified by DNA sequencing of PCR-amplified exon 2-intron 2-exon 3 amplicons. Furthermore, we determined the degree of HLA-C compatibility in 287 matched pairs that could be formed from 73 patients and their 184 potential unrelated donors compatible for HLA-AB by serology and for HLA-DRB1/ B3/B5 by oligotyping. Cw mismatches were identified in 42.1% of these pairs, and AB-subtype oligotyping showed that 30% of these Cw-incompatible pairs were also mismatched for A or B-locus subtype. The degree of HLA-C incompatibility was strongly influenced by the linkage with B alleles and by the ABDR haplotypes. Cw alleles linked with B*4403, B*5101, B18, and B62 haplotypes were frequently mismatched. Apparently high resolution DNA typing for HLA-AB does not result in full matching at locus C. Since HLA-C polymorphism is recognized by alloreactive CTLs, such incompatibilities might be as relevant as AB-subtype mismatches in clinical transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the end of the last millennium, the focused ion beam scanning electron microscopy (FIB-SEM) has progressively found use in biological research. This instrument is a scanning electron microscope (SEM) with an attached gallium ion column and the 2 beams, electrons and ions (FIB) are focused on one coincident point. The main application is the acquisition of three-dimensional data, FIB-SEM tomography. With the ion beam, some nanometres of the surface are removed and the remaining block-face is imaged with the electron beam in a repetitive manner. The instrument can also be used to cut open biological structures to get access to internal structures or to prepare thin lamella for imaging by (cryo-) transmission electron microscopy. Here, we will present an overview of the development of FIB-SEM and discuss a few points about sample preparation and imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Haematopoietic stem cell transplantation (HSCT) is a highly specialised procedure used to treat malignancies of the lymphohaematopoietic system as well as some acquired and inherited disorders of the blood. This analysis by the Swiss Blood Stem Cell Transplantation Group, based on data from 2008-2011, describes, treatment rates in Switzerland for specific indications and compares this with data from Germany, France, Italy and the Netherlands, corrected for the size of the population. Differences in transplant rates, in rates for particular indications, and in the use of specific transplant technologies such as use of unrelated donors, use of cord blood or mismatched family donors are described. These data are put in correlation with donor availability from international registries and with number of transplant teams and number of procedures per team all corrected for population size.