7 resultados para microtensile bond strength test
em Université de Lausanne, Switzerland
Resumo:
Purpose: To evaluate whether the correlation between in vitro bond strength data and estimated clinical retention rates of cervical restorations after two years depends on pooled data obtained from multicenter studies or single-test data. Materials and Methods: Pooled mean data for six dentin adhesive systems (Adper Prompt L-Pop, Clearfil SE, OptiBond FL, Prime & Bond NT, Single Bond, and Scotchbond Multipurpose) and four laboratory methods (macroshear, microshear, macrotensile and microtensile bond strength test) (Scherrer et al, 2010) were correlated to estimated pooled two-year retention rates of Class V restorations using the same adhesive systems. For bond strength data from a single test institute, the literature search in SCOPUS revealed one study that tested all six adhesive systems (microtensile) and two that tested five of the six systems (microtensile, macroshear). The correlation was determined with a database designed to perform a meta-analysis on the clinical performance of cervical restorations (Heintze et al, 2010). The clinical data were pooled and adjusted in a linear mixed model, taking the study effect, dentin preparation, type of isolation and bevelling of enamel into account. A regression analysis was carried out to evaluate the correlation between clinical and laboratory findings. Results: The results of the regression analysis for the pooled data revealed that only the macrotensile (adjusted R2 = 0.86) and microtensile tests (adjusted R2 = 0.64), but not the shear and the microshear tests, correlated well with the clinical findings. As regards the data from a single-test institute, the correlation was not statistically significant. Conclusion: Macrotensile and microtensile bond strength tests showed an adequate correlation with the retention rate of cervical restorations after two years. Bond strength tests should be carried out by different operators and/or research institutes to determine the reliability and technique sensitivity of the material under investigation.
Resumo:
OBJECTIVE: To determine if the results of resin-dentin microtensile bond strength (µTBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations. METHODS: Resin-dentin µTBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The µTBS testing was performed 8h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the µTBS values were calculated subsequently. RESULTS: Thirty-six clinical studies with 15 adhesive/restorative systems for which µTBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p<0.05). There was a significant correlation between µTBS values both after 8h and 6 months of storage and marginal discoloration (r=0.54 and r=0.67, respectively). However, the same correlation was not found between µTBS values and the retention rate, clinical index or marginal integrity. SIGNIFICANCE: As µTBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations.
Resumo:
OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.
Resumo:
This study was conducted to analyze whether internal (IR) and external (ER) rotator shoulder muscles weakness and/or imbalance collected through a preseason assessment could be predictors of subsequent shoulder injury during a season in handball players. In preseason, 16 female elite handball players (HPG) and 14 healthy female nonathletes (CG) underwent isokinetic IR and ER strength test with use of a Con-Trex® dynamometer in a seated position with 45° shoulder abduction in scapular plane, at 60, 120 and 240°/s in concentric and at 60°/s in eccentric, for both sides. An imbalanced muscular strength profile was determined using -statistically selected cut-offs from CG values. For HPG, all newly incurred shoulder injuries were reported during the season. There were significant differences between HPG and CG only for dominant eccentric IR strength, ER/IR ratio at 240°/s and for IRecc/ERcon ratio. In HPG, IR and ER strength was higher, and ER/IR ratios lower for dominant than for nondominant side. The relative risk was 2.57 (95%CI: 1.60-3.54; P<0.05) if handball players had an imbalanced muscular strength profile. In youth female handball players IR and ER muscle strength increases on the dominant side without ER/IR imbalances; and higher injury risk was associated with imbalanced muscular strength profile.
Resumo:
CONTEXT: Fatigue-induced alterations in foot mechanics may lead to structural overload and injury. OBJECTIVES: To investigate how a high-intensity running exercise to exhaustion modifies ankle plantar-flexor and dorsiflexor strength and fatigability, as well as plantar-pressure distribution in adolescent runners. DESIGN: Controlled laboratory study. SETTING: Academy research laboratory. PATIENTS OR OTHER PARTICIPANTS: Eleven male adolescent distance runners (age = 16.9 ± 2.0 years, height = 170.6 ± 10.9 cm, mass = 54.6 ± 8.6 kg) were tested. INTERVENTION(S): All participants performed an exhausting run on a treadmill. An isokinetic plantar-flexor and dorsiflexor maximal-strength test and a fatigue test were performed before and after the exhausting run. Plantar-pressure distribution was assessed at the beginning and end of the exhausting run. MAIN OUTCOME MEASURE(S): We recorded plantar-flexor and dorsiflexor peak torques and calculated the fatigue index. Plantar-pressure measurements were recorded 1 minute after the start of the run and before exhaustion. Plantar variables (ie, mean area, contact time, mean pressure, relative load) were determined for 9 selected regions. RESULTS: Isokinetic peak torques were similar before and after the run in both muscle groups, whereas the fatigue index increased in plantar flexion (28.1%; P = .01) but not in dorsiflexion. For the whole foot, mean pressure decreased from 1 minute to the end (-3.4%; P = .003); however, mean area (9.5%; P = .005) and relative load (7.2%; P = .009) increased under the medial midfoot, and contact time increased under the central forefoot (8.3%; P = .01) and the lesser toes (8.9%; P = .008). CONCLUSIONS: Fatigue resistance in the plantar flexors declined after a high-intensity running bout performed by adolescent male distance runners. This phenomenon was associated with increased loading under the medial arch in the fatigued state but without any excessive pronation.
Resumo:
The atomic force microscope is not only a very convenient tool for studying the topography of different samples, but it can also be used to measure specific binding forces between molecules. For this purpose, one type of molecule is attached to the tip and the other one to the substrate. Approaching the tip to the substrate allows the molecules to bind together. Retracting the tip breaks the newly formed bond. The rupture of a specific bond appears in the force-distance curves as a spike from which the binding force can be deduced. In this article we present an algorithm to automatically process force-distance curves in order to obtain bond strength histograms. The algorithm is based on a fuzzy logic approach that permits an evaluation of "quality" for every event and makes the detection procedure much faster compared to a manual selection. In this article, the software has been applied to measure the binding strength between tubuline and microtubuline associated proteins.
Resumo:
The 2013 survey addressed the following objectives: Primary objectives : a) Distribution of health behaviors related to NCDs, particularly tobacco use, alcohol drinking, and physical activity ; b) Distribution of the main modifiable risk factors of NCDs, particularly blood pressure, adiposity markers, diabetes and blood lipids ; c) Rates of awareness, treatment and control of hypertension, diabetes and dyslipidemia ; d) Comparison of findings in the survey 2013 with results in previous similar NCD surveys in 1989, 1994, 2004 ; e) Dietary patterns ; f) Knowledge, attitudes and practices related to NCDs and NCD risk factors. Secondary objectives : g) Assessment of indicators of quality of health (e.g. SF‐12) ; h) Assessment of psychological stress and relation with NCD ; i) Assessment of several indicators of frailty (e.g. handgrip strength test, chair strand test, functional limitations) ; j) Assessment of knowledge and level of agreement with current policies on tobacco control ; k) Use of public and private health care services, particularly for NCDs ; l) Exposure to advice on health behaviors given by health professionals at health care level ; m) Burden of chronic diseases not related to the main NCDs (e.g. musculoskeletal, mental health, etc) ; n) Screening of selected cancers ; o) Assessment of the kidney function ; p) Frequency of heart arrhythmias (one‐lead ECG) and heart murmurs (auscultation) ; q) Assessment of bone mineral density (ultrasound of calcaneus) ; r) Exposure of the population to mass media, particularly in relation to health programs, and use by the population of new communication technologies ; s) Assessment of a number of social variables and their association with the variables measured in the survey ; t) More generally, the survey provides broad information (medical, social, environment, etc) that can be useful for tailoring NCD prevention and control programs.