7 resultados para methylene blue sensitized poly(vinyl alcohol)

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Is surgery for primary hyperparathyroidism easier when methylene blue (MB) is given preoperatively? This retrospective study compares the durations of interventions for primary hyperparathyroidism carried out after i.v. MB administration to those when no MB was given. Over a period of 20 years (June 1976 to December 1996), 175 consecutive patients (56 men and 119 women, with ages ranging from 16 to 92, mean 59.6) were operated upon for primary hyperparathyrodism; 55 were operated before February 1986--the period when BM was introduced routinely, and 120 after. Thirty-two other patients were excluded from the study: 14 had had a previous cervicotomy and 18 another procedure in addition to the parathyroidectomy (usually on the thyroid gland), two conditions which prolonged the time devoted to parathyroid identification and excision. Preoperative calcemia averaged 2.97 mmol/L (2.34 to 4.59) and mean preoperative PTH was equal to 2.6 times the upper normal limit (0.5 to 24.1). Both groups were similar for as age, sex, preoperative calcium and PTH, and histologies. Methylene blue was administered intravenously (5 mg/kg diluted in 500 cc of 5% glucose) over a period of time of one hour starting two hours prior to surgery. All 175 procedures were performed by two surgeons and duration of surgery was recorded from the anesthesiologist's notes. There were 149 adenomas (85%), 24 hyperplasias (14%), a combination of both in two, and unspecified in two others. Except for a case of acute lower back pain synchronous to the injection of the dye (which was immediately stopped), MB was well tolerated. Mean duration for the 55 interventions performed without MB was 68 minutes (35 to 140, median 60), compared to 49 minutes for the 120 procedures carried out after MB had been given (20 to 155, median 45). Differences in operative, times were highly significant (p < 10(-6) and represented a gain of time of 27%. Surgery for primary hyperparathyroidism was significantly shorter when it was preceded by the administration of MB, a dye which facilitates the identification of pathologic parathyroid gland(s).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methylene blue (MB) and light are used for virus inactivation of plasma for transfusion. However, the presence of MB has been the subject of concern, and efforts have been made to efficiently remove the dye after photo-treatment. For this study, plasma was collected by apheresis from 10 donors (group A), then treated using the MacoPharma THERAFLEX procedure (MB; 1 microM, and light exposure; 180 J/cm(2)) (group B), and finally filtered in order to remove the dye (group C). Proteins were analyzed by two-dimensional electrophoresis, and peptides showing modifications were characterized by mass spectrometry. Clottable and antigenic fibrinogen levels, as well as fibrin polymerization time were measured. Analyses of the gels focused on a region corresponding to pI between 4.5 and 6.5, and M(r) from 7000 to 58 000. In this area, 387 +/- 47 spots matched, and four of these spots presented significant modifications. They corresponded to changes of the gamma-chain of fibrinogen, of transthyretin, and of apolipoprotein A-I, respectively. A decrease of clottable fibrinogen and a prolongation of fibrin polymerization time were observed in groups B and C. Removal of MB by filtration was not responsible for additional protein alterations. The effect of over-treatment of plasma by very high concentrations of MB (50 microM) in association with prolonged light exposure (3 h) was also analyzed, and showed complex alterations of most of the plasma proteins, including fibrinogen gamma-chain, transthyretin, and apolipoprotein A-I. Our data indicates that MB treatment at high concentration and prolonged illumination severely injure plasma proteins. By contrast, at the MB concentration used to inactivate viruses, damages are apparently very restricted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the use of in situ implant formation that incorporates superparamagnetic iron oxide nanoparticles (SPIONs) as a form of minimally invasive treatment of cancer lesions by magnetically induced local hyperthermia. We developed injectable formulations that form gels entrapping magnetic particles into a tumor. We used SPIONs embedded in silica microparticles to favor syringeability and incorporated the highest proportion possible to allow large heating capacities. Hydrogel, single-solvent organogel and cosolvent (low-toxicity hydrophilic solvent) organogel formulations were injected into human cancer tumors xenografted in mice. The thermoreversible hydrogels (poloxamer, chitosan), which accommodated 20% w/v of the magnetic microparticles, proved to be inadequate. Alginate hydrogels, however, incorporated 10% w/v of the magnetic microparticles, and the external gelation led to strong implants localizing to the tumor periphery, whereas internal gelation failed in situ. The organogel formulations, which consisted of precipitating polymers dissolved in single organic solvents, displayed various microstructures. A 8% poly(ethylene-vinyl alcohol) in DMSO containing 40% w/v of magnetic microparticles formed the most suitable implants in terms of tumor casting and heat delivery. Importantly, it is of great clinical interest to develop cosolvent formulations with up to 20% w/v of magnetic microparticles that show reduced toxicity and centered tumor implantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biological and therapeutic responses to hyperthermia, when it is envisaged as an anti-tumor treatment modality, are complex and variable. Heat delivery plays a critical role and is counteracted by more or less efficient body cooling, which is largely mediated by blood flow. In the case of magnetically mediated modality, the delivery of the magnetic particles, most often superparamagnetic iron oxide nanoparticles (SPIONs), is also critically involved. We focus here on the magnetic characterization of two injectable formulations able to gel in situ and entrap silica microparticles embedding SPIONs. These formulations have previously shown suitable syringeability and intratumoral distribution in vivo. The first formulation is based on alginate, and the second on a poly(ethylene-co-vinyl alcohol) (EVAL). Here we investigated the magnetic properties and heating capacities in an alternating magnetic field (141 kHz, 12 mT) for implants with increasing concentrations of magnetic microparticles. We found that the magnetic properties of the magnetic microparticles were preserved using the formulation and in the wet implant at 37 degrees C, as in vivo. Using two orthogonal methods, a common SLP (20 Wg(-1)) was found after weighting by magnetic microparticle fraction, suggesting that both formulations are able to properly carry the magnetic microparticles in situ while preserving their magnetic properties and heating capacities. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The radicality of wound debridement is an important feature of the surgical treatment of pressure sores. Several methods such as injection of methylene blue or hydrogen peroxide have been proposed to facilitate and optimise the surgical debridement technique, but none of them proved to be sufficient. We present an innovative modification of the pseudo-tumour technique consisting in the injection of fluid silicone. Vulcanisation of the silicone leads to pressure-sore moulding, permitting a more radical and sterile excision. In a series of 10 paraplegic patients presenting with ischial pressure sores, silicone moulding was used to facilitate debridement. Radical en bloc debridement was achieved in all patients. After a minimal follow-up of 2 years, no complications and recurrences occurred. A three-dimensional (3D) analysis of the silicone prints objectified the pyramidal shape of ischial pressure sores. Our study showed that complete resection without capsular lesion can be easily achieved. Further, it allows the surgeon to analyse the shape and size of the resected defect, which might be helpful to select the appropriate defect coverage technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The antifungal agent fluconazole (FLC) is widely used in clinical practice. Monitoring FLC levels is useful in complicated clinical settings and in experimental infection models. A bioassay using Candida pseudotropicalis, a simple and cost-effective method, is validated only for FLC levels ranging from 5 to 40 mg/liter. An extension of the analytical range is needed to cover most yeast MICs. A new bioassay in RPMI agar containing methylene blue was developed using C. albicans DSY1024, a mutant rendered hypersusceptible to FLC constructed by the deletion of the multidrug efflux transporter genes CDR1, CDR2, CaMDR1, and FLU1. Reproducible standard curves were obtained with FLC concentrations in plasma ranging from 1 to 100 mg/liter (quadratic regression coefficient &gt; 0.997). The absolute sensitivity was 0.026 microg of FLC. The method was internally validated according to current guidelines for analytical method validation. Both accuracy and precision lied in the required +/-15% range. FLC levels measured by bioassay and by high-performance liquid chromatography (HPLC) performed with 62 plasma samples from humans and rats showed a strong correlation (coefficients, 0.979 and 0.995, respectively; percent deviations of bioassay from HPLC values, 0.44% +/- 15.31% and 2.66% +/- 7.54%, respectively). In summary, this newly developed bioassay is sensitive, simple, rapid, and inexpensive. It allows nonspecialized laboratories to determine FLC levels in plasma to within the clinically relevant concentration range and represents a useful tool for experimental treatment models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protein oxidation mechanisms result in a wide array of modifications, from backbone cleavage or protein crosslinking to more subtle modifications such as side chain oxidations. Protein oxidation occurs as part of normal regulatory processes, as a defence mechanism against oxidative stress, or as a deleterious processes when antioxidant defences are overcome. Because blood is continually exposed to reactive oxygen and nitrogen species, blood proteomics should inherently adopt redox proteomic strategies. In this review, we recall the biochemical basis of protein oxidation, review the proteomic methodologies applied to analyse redox modifications, and highlight some physiological and in vitro responses to oxidative stress of various blood components.