47 resultados para medullary canal diameter

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two new spumellarian radiolarian genera, Mendacastrum and Domuzdagia, are described from the lower Tithonian and lower Pliensbachian respectively. Both have a spherical cortical shell of actinommid type and a spherical or subspherical double medullary shell with the inner medullary shell of hagiastrid s.l. type. The inner medullary shell of Mendacastrum is of dactyliosphaerid or higumastrid s. sit. type, whereas that of Domuzdagia is of angulobracchiid type. Since they cannot be assigned to any described Mesozoic pyloniacean families, they are considered as type genera of two new families: Mendacastridae and Domuzdagiidae respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The early detection of medullary thyroid carcinoma (MTC) can improve patient prognosis, because histological stage and patient age at diagnosis are highly relevant prognostic factors. As a consequence, delay in the diagnosis and/or incomplete surgical treatment should correlate with a poorer prognosis for patients. Few papers have evaluated the specific capability of fine-needle aspiration cytology (FNAC) to detect MTC, and small series have been reported. This study conducts a meta-analysis of published data on the diagnostic performance of FNAC in MTC to provide more robust estimates. RESEARCH DESIGN AND METHODS: A comprehensive computer literature search of the PubMed/MEDLINE, Embase and Scopus databases was conducted by searching for the terms 'medullary thyroid' AND 'cytology', 'FNA', 'FNAB', 'FNAC', 'fine needle' or 'fine-needle'. The search was updated until 21 March 2014, and no language restrictions were used. RESULTS: Fifteen relevant studies and 641 MTC lesions that had undergone FNAC were included. The detection rate (DR) of FNAC in patients with MTC (diagnosed as 'MTC' or 'suspicious for MTC') on a per lesion-based analysis ranged from 12·5% to 88·2%, with a pooled estimate of 56·4% (95% CI: 52·6-60·1%). The included studies were statistically heterogeneous in their estimates of DR (I-square >50%). Egger's regression intercept for DR pooling was 0·03 (95% CI: -3·1 to 3·2, P = 0·9). The study that reported the largest MTC series had a DR of 45%. Data on immunohistochemistry for calcitonin in diagnosing MTC were inconsistent for the meta-analysis. CONCLUSIONS: The presented meta-analysis demonstrates that FNAC is able to detect approximately one-half of MTC lesions. These findings suggest that other techniques may be needed in combination with FNAC to diagnose MTC and avoid false negative results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To report a single-center experience in 19 patients (pts) with anal canal cancer treated with helical tomotherapy (HT) and concurrent chemotherapy, and compare the dosimetric results with fixed-field intensitymodulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D RT). Materials and Methods: Between 2007 and 2008, 19 consecutive pts were treated with HT and concurrent CT for anal canal cancer. Median age was 59 years (range, 38−83), and female/male ratio was 14/5. The majority of the pts had T2 or T3 tumours (68.4%), and 52.6% had positive lymph nodes. In all 19 pts, pelvic and inguinal nodes, and tumour irradiation was given using HT upto a median dose of 36 Gy (1.8 Gy/fr) followed by a 1-week gap. A boost dose of 23.4 Gy (1.8 Gy/fr) was delivered to the tumour and involved nodes using 3DRT (n = 12), HT (n = 6), or IMRT (n = 1). Simultaneous integrated boost was used in none of the pts. All but one patient with a T1N0 tumour received concomitant mitomycin/5- fluorouracil (n = 12) or mitomycin/capecitabin (n = 7) CT. Toxicity was scored according to the Common Terminology Criteria for Adverse Events (NCICTCAE v3.0). HT plans and treatments were generated using Tomotherapy, Inc., software and hardware; and 3D or IMRT boost plans with the CMS treatment planning system (TPS), using 6−18 MV photons from a Siemens Primus accelerator. For dosimetric comparison, computed tomography data sets of 10 pts were imported into the TPS, and 3D and 5-field step-andshoot IMRT plans were generated for each case. Plans were optimized with the aim of assessing organs at risk (OAR) and healthy-tissue sparing while enforcing highly conformal target coverage, and evaluated by dose-volume histograms (DVH) of planning target volumes (PTV) and OAR. Results: With a median follow-up of 13 months (range, 3−18), all pts are alive and well; except one patient developing local recurrence at 12 months. No patient developed grade 3 or more acute toxicity. No unplanned treatment interruption was necessary because of toxicity. With 360-degree-of-freedom beam projection, HT showed an advantage over 3D or IMRT plans in terms of dose conformity around the PTV, and dose gradients were steeper outside the PTV, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards. Conclusion: We conclude that HT combined with concurrent chemotherapy for anal canal cancer is effective and tolerable. Compared to 3DRT or 5-field IMRT, there is better conformity around the PTV, and OAR sparing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mixed medullary-follicular thyroid carcinoma denotes a rare and heterogeneous group of tumors displaying morphological and immunophenotypical features of both origins within the same lesion. METHOD: We report a case of a 41-year-old woman with a lump in the right side of the neck, increasing in pain and size over several weeks. Serum levels of calcitonine (1140 ng/L) and carcinoembryonic antigen (288 microg/L) were very high. Fine-needle aspiration cytology suggested a diagnosis of medullary thyroid carcinoma. Total thyroidectomy, along with bilateral functional neck and mediastinal lymph-node dissection, were performed. RESULTS: The histopathological examination yielded a diagnosis of medullary carcinoma in the right thyroid lobe, closely intermingled with a nonencapsulated classical papillary carcinoma. One ipsilateral lymph node showed micrometastasis of the medullary counterpart. CONCLUSION: When compared with other cases reported in literature, this particular presentation should be recognized, if required, morphologic and functional criteria are used. The treatment is mostly surgical, driven by the medullary component. The presence of micrometastasis in 1 ipsilateral cervical lymph-node underlines the importance of cervicomediastinal lymph-node dissection and careful searching for metastatic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Measures of the degree of lumbar spinal stenosis (LSS) such as antero-posterior diameter of the canal, and dural sac cross sectional area vary, and do not correlate with symptoms or results of surgery. We created a grading system, comprised of seven categories, based on the morphology of the dural sac and its contents as seen on T2 axial images. The categories take into account the ratio of rootlet/ CSF content. Grade A indicates no significant compression, grade D is equivalent to a total myelograhic block. We compared this classification with commonly used criteria of severity of stenosis. Methods: Fifty T2 axial MRI images taken at disc level from 27 symptomatic LSS patients undergoing decompressive surgery were classified twice by two radiologists and three spinal surgeons working at different institutions and countries. Dural sac cross-sectional surface area and AP diameter of the canal were measured both at disc and pedicle level from DICOM images using OsiriX software. Intraand inter-observer reliability were assessed using Cohen's, Fleiss' kappa statistics, and t test. Results: For the morphological grading the average intra-and inter observer kappas were 0.76 and 0.69+, respectively, for physicians working in the study originating country. Combining all observers the kappa values were 0.57 ± 0.19. and 0.44 ± 0.19, respectively. AP diameter and dural sac cross-sectional area measurements showed no statistically significant differences between observers. No correlation between morphological grading and AP diameter or dural sac crosssectional areawas observed in 13 (26%) and 8 cases (16%), respectively. Discussion: The proposed morphological grading relies on the identification of the dural sac and CSF better seen on full MRI series. This was not available to the external observers, which might explain the lower overall kappa values. Since no specific measurement tools are needed the grading suits everyday clinical practice and favours communication of degree of stenosis between practising physicians. The absence of a strict correlation with the dural sac surface suggests that measuring the surface alone might be insufficient in defining LSS as it is essentially a mismatch between the spinal canal and its contents. This grading is now adopted in our unit and further studies concentrating on relation between morphology, clinical symptoms and surgical results are underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfully and the patient made an uneventfully recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Quantitative measures of degree of lumbar spinal stenosis (LSS) such as antero-posterior diameter of the canal or dural sac cross sectional area vary widely and do not correlate with clinical symptoms or results of surgical decompression. In an effort to improve quantification of stenosis we have developed a grading system based on the morphology of the dural sac and its contents as seen on T2 axial images. The grading comprises seven categories ranging form normal to the most severe stenosis and takes into account the ratio of rootlet/CSF content. Material and methods: Fifty T2 axial MRI images taken at disc level from twenty seven symptomatic lumbar spinal stenosis patients who underwent decompressive surgery were classified into seven categories by five observers and reclassified 2 weeks later by the same investigators. Intra- and inter-observer reliability of the classification were assessed using Cohen's and Fleiss' kappa statistics, respectively. Results: Generally, the morphology grading system itself was well adopted by the observers. Its success in application is strongly influenced by the identification of the dural sac. The average intraobserver Cohen's kappa was 0.53 ± 0.2. The inter-observer Fleiss' kappa was 0.38 ± 0.02 in the first rating and 0.3 ± 0.03 in the second rating repeated after two weeks. Discussion: In this attempt, the teaching of the observers was limited to an introduction to the general idea of the morphology grading system and one example MRI image per category. The identification of the dimension of the dural sac may be a difficult issue in absence of complete T1 T2 MRI image series as it was the case here. The similarity of the CSF to possibly present fat on T2 images was the main reason of mismatch in the assignment of the cases to a category. The Fleiss correlation factors of the five observers are fair and the proposed morphology grading system is promising.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The presence of a pre-existing narrow spinal canal may have an important place in the ethiopathogenesis of lumbar spinal stenosis. By consequence the study of the development of the spinal canal is crucial. The first goal of this work is to do a comprehensive literature search and to give an essential view on the development of spinal canal and its depending factors studied until now. The second goal is to give some considerations and hypothesize new leads for clinically useful researches. MATERIALS AND METHODS: A bibliographical research was executed using different search engines: PubMed, Google Schoolar ©, Ovid ® and Web Of Science ©. Free sources and avaible from the University of Lausanne (UNIL) and Centre Hospitalier Universitaire Vaudois (CHUV) were used. At the end of the bibliographic researches 114 references were found, 85 were free access and just 41 were cited in this work. Most of the found references are in English or in French. RESULTS AND DISCUSSION: The spinal canal is principally limited by the vertebrae which have a mesodermal origin. The nervous (ectodermal) tissue significantly influences the growth of the canal. The most important structure participating in the spinal canal growth is the neurocentral synchondrosis in almost the entire vertebral column. The fusion of the half posterior arches seems to have less importance for the canal size. The growth is not homogeneous but, depends on the vertebral level. Timing, rate and growth potentials differ by regions. Especially in the case of the lumbar segment, there is a craniocaudal tendency which entails a greater post-natal catch-up growth for distal vertebrae. Trefoil-shape of the L5 canal is the consequence of a sagittal growth deficiency. The spinal canal shares some developmental characteristics with different structures and systems, especially with the central nervous system. It may be the consequence of the embryological origin. It is supposed that not all the related structures would be affected by a growth impairment because of the different catch-up potentials. Studies found that narrower spinal canals might be related with cardiovascular and gastrointestinal symptoms, lower thymic function, bone mineral content, dental hypoplasia and Harris' lines. Anthropometric correlations found at birth disappear during the pediatric age. All factors which can affect bone and nervous growth might be relevant. Genetic predispositions are the only factors that can never be changed but the real impact is to ascertain. During the antenatal period, all the elements determining a good supply of blood and oxygen may influence the vertebral canal development, for example smoking during pregnancy. Diet is a crucial factor having an impact on both antenatal and postnatal growth. Proteins intake is the only proved dietetic relationship found in the bibliographic research of this work. The mechanical effects due to locomotion changes are unknown. Socioeconomic situation has an impact on several influencing factors and it is difficult to study it owing to numerous bias. CONCLUSIONS: A correct growth of spinal canal is evidently relevant to prevent not-degenerative stenotic conditions. But a "congenital" narrower canal may aggravate degenerative stenosis. This concerns specific groups of patient. If the size of the canal is highly involved in the pathogenesis of common back pains, a hypothetical measure to prevent developmental impairments could have a not- negligible impact on the society. It would be interesting to study more about dietetic necessities for a good spinal canal development. Understanding the relationship between nervous tissues and vertebra it might be useful in identifying what is needed for the ideal development. Genetic importance and the post-natal influences of upright standing on the canal growth remain unsolved questions. All these tracks may have a double purpose: knowing if it is possible to decrease the incidence of narrower spinal canal and consequently finding possible preventive measures. The development of vertebral canal is a complex subject which ranges over a wide variety of fields. The knowledge of this subject is an indispensable tool to understand and hypothesize the influencing factors that might lead to stenotic conditions. Unfortunately, a lack of information makes difficult to have a complete and satisfactory interdisciplinary vision.