83 resultados para mean speed
em Université de Lausanne, Switzerland
Resumo:
The microenvironment hosting a tumor actively participates in regulating tumor cell proliferation, migration, and invasion. Among the extracellular matrix proteins enriched in the stroma of carcinomas are the tenascin family members tenascin-C and tenascin-W. Whereas tenascin-C overexpression in gliomas is known to correlate with poor prognosis, the status of tenascin-W in brain tumors has not been investigated so far. In the present study, we analyzed protein levels of tenascin-W in 38 human gliomas and found expression of tenascin-W in 80% of the tumor samples, whereas no tenascin-W could be detected in control, nontumoral brain tissues. Double immunohistochemical staining of tenascin-W and von Willebrand factor revealed that tenascin-W is localized around blood vessels, exclusively in tumor samples. In vitro, the presence of tenascin-W increased the proportion of elongated human umbilical vein endothelial cells (HUVECs) and augmented the mean speed of cell migration. Furthermore, tenascin-W triggered sprouting of HUVEC spheroids to a similar extent as the proangiogenic factor tenascin-C. In conclusion, our study identifies tenascin-W as a candidate biomarker for brain tumor angiogenesis that could be used as a molecular target for therapy irrespective of the glioma subtype.-Martina, E., Degen, M., Rüegg, C., Merlo, A., Lino, M. M., Chiquet-Ehrismann, R., Brellier, F. Tenascin-W is a specific marker of glioma-associated blood vessels and stimulates angiogenesis in vitro.
Resumo:
PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.
Resumo:
PURPOSE: To explore whether triaxial accelerometric measurements can be utilized to accurately assess speed and incline of running in free-living conditions. METHODS: Body accelerations during running were recorded at the lower back and at the heel by a portable data logger in 20 human subjects, 10 men, and 10 women. After parameterizing body accelerations, two neural networks were designed to recognize each running pattern and calculate speed and incline. Each subject ran 18 times on outdoor roads at various speeds and inclines; 12 runs were used to calibrate the neural networks whereas the 6 other runs were used to validate the model. RESULTS: A small difference between the estimated and the actual values was observed: the square root of the mean square error (RMSE) was 0.12 m x s(-1) for speed and 0.014 radiant (rad) (or 1.4% in absolute value) for incline. Multiple regression analysis allowed accurate prediction of speed (RMSE = 0.14 m x s(-1)) but not of incline (RMSE = 0.026 rad or 2.6% slope). CONCLUSION: Triaxial accelerometric measurements allows an accurate estimation of speed of running and incline of terrain (the latter with more uncertainty). This will permit the validation of the energetic results generated on the treadmill as applied to more physiological unconstrained running conditions.
Resumo:
Activity monitors based on accelerometry are used to predict the speed and energy cost of walking at 0% slope, but not at other inclinations. Parallel measurements of body accelerations and altitude variation were studied to determine whether walking speed prediction could be improved. Fourteen subjects walked twice along a 1.3 km circuit with substantial slope variations (-17% to +17%). The parameters recorded were body acceleration using a uni-axial accelerometer, altitude variation using differential barometry, and walking speed using satellite positioning (DGPS). Linear regressions were calculated between acceleration and walking speed, and between acceleration/altitude and walking speed. These predictive models, calculated using the data from the first circuit run, were used to predict speed during the second circuit. Finally the predicted velocity was compared with the measured one. The result was that acceleration alone failed to predict speed (mean r = 0.4). Adding altitude variation improved the prediction (mean r = 0.7). With regard to the altitude/acceleration-speed relationship, substantial inter-individual variation was found. It is concluded that accelerometry, combined with altitude measurement, can assess position variations of humans provided inter-individual variation is taken into account. It is also confirmed that DGPS can be used for outdoor walking speed measurements, opening up new perspectives in the field of biomechanics.
Resumo:
BACKGROUND: Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. METHODS: Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATP) of vastus lateralis was determined in vivo by P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O consumption) was characterized using ATP per St3 respiration (ATP/St3). RESULTS: In vitro St3 respiration was significantly correlated with in vivo ATP (r = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO peak (r = .33, p = .006). ATP (r = .158, p = .03) and VO peak (r = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATP/St3 and VO peak in a multiple linear regression model improved the prediction of preferred walking speed (r = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. CONCLUSIONS: Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age.
Resumo:
BACKGROUND: Habitual walking speed predicts many clinical conditions later in life, but it declines with age. However, which particular exercise intervention can minimize the age-related gait speed loss is unclear. PURPOSE: Our objective was to determine the effects of strength, power, coordination, and multimodal exercise training on healthy old adults' habitual and fast gait speed. METHODS: We performed a computerized systematic literature search in PubMed and Web of Knowledge from January 1984 up to December 2014. Search terms included 'Resistance training', 'power training', 'coordination training', 'multimodal training', and 'gait speed (outcome term). Inclusion criteria were articles available in full text, publication period over past 30 years, human species, journal articles, clinical trials, randomized controlled trials, English as publication language, and subject age ≥65 years. The methodological quality of all eligible intervention studies was assessed using the Physiotherapy Evidence Database (PEDro) scale. We computed weighted average standardized mean differences of the intervention-induced adaptations in gait speed using a random-effects model and tested for overall and individual intervention effects relative to no-exercise controls. RESULTS: A total of 42 studies (mean PEDro score of 5.0 ± 1.2) were included in the analyses (2495 healthy old adults; age 74.2 years [64.4-82.7]; body mass 69.9 ± 4.9 kg, height 1.64 ± 0.05 m, body mass index 26.4 ± 1.9 kg/m(2), and gait speed 1.22 ± 0.18 m/s). The search identified only one power training study, therefore the subsequent analyses focused only on the effects of resistance, coordination, and multimodal training on gait speed. The three types of intervention improved gait speed in the three experimental groups combined (n = 1297) by 0.10 m/s (±0.12) or 8.4 % (±9.7), with a large effect size (ES) of 0.84. Resistance (24 studies; n = 613; 0.11 m/s; 9.3 %; ES: 0.84), coordination (eight studies, n = 198; 0.09 m/s; 7.6 %; ES: 0.76), and multimodal training (19 studies; n = 486; 0.09 m/s; 8.4 %, ES: 0.86) increased gait speed statistically and similarly. CONCLUSIONS: Commonly used exercise interventions can functionally and clinically increase habitual and fast gait speed and help slow the loss of gait speed or delay its onset.
Resumo:
In contemporary society, religious signification and secular systems mix and influence each other. Holistic conceptions of a world in which man is integrated harmoniously with nature meet representations of a world run by an immanent God. On the market of the various systems, the individual goes from one system to another, following his immediate needs and expectations without necessarily leaving any marks in a meaningful long term system. This article presents the first results of an ongoing research in Switzerland on contemporary religion focusing on (new) paths of socialization of modern that individuals and the various (non-) belief systems that they simultaneously develop
Resumo:
Background: Previous studies reported an increase of mean platelet volume (MPV) in patients with acute ischemic stroke. However, its correlation with stroke severity has not been investigated. Moreover, studies on the association of MPV with functional outcome yielded inconsistent results. Methods: We included all consecutive ischemic stroke patients admitted to CHUV (Centre Hospitalier Universitaire Vaudois) Neurology Service within 24 h after stroke onset who had MPV measured on admission. The association of MPV with stroke severity (NIHSS score at admission and at 24 h) and outcome (Rankin Scale score at 3 and 12 months) was analyzed in univariate analysis. The chi(2) test was performed to compare the frequency of minor strokes (NIHSS score </=4) and good functional outcome (Rankin Scale score </=2) across MPV quartiles. The ANOVA test was used to compare MPV between stroke subtypes according to the TOAST classification. Student's two-tailed unpaired t test was performed to compare MPV between lacunar and nonlacunar strokes. MPV was generated at admission by the Sysmex XE-2100 automated cell counter (Sysmex Corporation, Kobe, Japan) from EDTA blood samples. Results: There was no significant difference in the frequency of minor strokes (p = 0.46) and good functional outcome (p = 0.06) across MPV quartiles. MPV was not associated with stroke severity or outcome in univariate analysis. There was no significant difference in MPV between stroke subtypes according to the TOAST classification (p = 0.173) or between lacunar and nonlacunar strokes (10.50 +/- 0.91 vs. 10.40 +/- 0.81 fl, p = 0.322). Conclusions: MPV, assessed within 24 h after ischemic stroke onset, is not associated with stroke severity or functional outcome.
Resumo:
Challenging environmental conditions, including heat and humidity, cold, and altitude, pose particular risks to the health of Olympic and other high-level athletes. As a further commitment to athlete safety, the International Olympic Committee (IOC) Medical Commission convened a panel of experts to review the scientific evidence base, reach consensus, and underscore practical safety guidelines and new research priorities regarding the unique environmental challenges Olympic and other international-level athletes face. For non-aquatic events, external thermal load is dependent on ambient temperature, humidity, wind speed and solar radiation, while clothing and protective gear can measurably increase thermal strain and prompt premature fatigue. In swimmers, body heat loss is the direct result of convection at a rate that is proportional to the effective water velocity around the swimmer and the temperature difference between the skin and the water. Other cold exposure and conditions, such as during Alpine skiing, biathlon and other sliding sports, facilitate body heat transfer to the environment, potentially leading to hypothermia and/or frostbite; although metabolic heat production during these activities usually increases well above the rate of body heat loss, and protective clothing and limited exposure time in certain events reduces these clinical risks as well. Most athletic events are held at altitudes that pose little to no health risks; and training exposures are typically brief and well-tolerated. While these and other environment-related threats to performance and safety can be lessened or averted by implementing a variety of individual and event preventative measures, more research and evidence-based guidelines and recommendations are needed. In the mean time, the IOC Medical Commission and International Sport Federations have implemented new guidelines and taken additional steps to mitigate risk even further.
Resumo:
PURPOSE: The aim of this study was to compare the mechanical external work (per kg) and pendular energy transduction at preferred walking speed (PWS) in obese versus normal body mass subjects to investigate whether obese adults adopt energy conserving gait mechanics. METHODS: The mechanical external work (Wext) and the fraction of mechanical energy recovered by the pendular mechanism (Rstep) were computed using kinematic data acquired by an optoelectronic system and were compared in 30 obese (OG; body mass index [BMI] = 39.6 +/- 0.6 kg m(-2); 29.5 +/- 1.3 yr) and 19 normal body mass adults (NG; BMI = 21.4 +/- 0.5 kg m(-2); 31.2 +/- 1.2 yr) walking at PWS. RESULTS: PWS was significantly lower in OG (1.18 +/- 0.02 m s(-1)) than in NG (1.33 +/- 0.02 m s(-1); P <or= 0.001). There was no significant difference in Wext per unit mass between groups (OG: 0.36 +/- 0.03 J kg(-1) m(-1); NG: 0.31 +/- 0.02 J kg(-1) m(-1); P = 0.12). Rstep was significantly lower in OG (68.4% +/- 2.0%) compared with NG (74.4% +/- 1.0%; P = 0.01). In OG only, Wext per unit mass was positively correlated with PWS (r = 0.57; P < 0.001). CONCLUSION: Obese adults do not appear to alter their gait to improve pendular energy transduction and may select slower PWS to reduce mechanical and metabolic work.
Resumo:
BACKGROUND: Cost effective means of assessing the levels of risk factors in the population have to be defined in order to monitor these factors over time and across populations. This study is aimed at analyzing the difference in population estimates of the mean levels of body mass index (BMI) and the prevalences of overweight, between health examination survey and telephone survey. METHODS: The study compares the results of two health surveys, one by telephone (N=820) and the other by physical examination (N=1318). The two surveys, based on independent random samples of the population, were carried out over the same period (1992-1993) in the same population (canton of Vaud, Switzerland). RESULTS: Overall participation rates were 67% and 53% for the health interview survey (HIS) and the health examination survey (HES) respectively. In the HIS, the reporting rate was over 98% for weight and height values. Self-reported weight was on average lower than measured weight, by 2.2 kg in men and 3.5 kg in women, while self-reported height was on average greater than measured height, by 1.2 cm in men and 1.9 cm in women. As a result, in comparison to HES, HIS led to substantially lower mean levels of BMI, and to a reduction of the prevalence rates of obesity (BMI>30 kg/m(2)) by more than a half. These differences are larger for women than for men. CONCLUSION: The two surveys were based on different sampling procedures. However, this difference in design is unlikely to explain the systematic bias observed between self-reported and measured values for height and weight. This bias entails the overall validity of BMI assessment from telephone surveys.
Resumo:
A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy±precision for both groups was 3.4±4.6cm for stride length, 4.3±4.2cm/s for speed and 0.5±2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.
Resumo:
Moderate alcohol consumption has been associated with lower coronary artery disease (CAD) risk. However, data on the CAD risk associated with high alcohol consumption are conflicting. The aim of this study was to examine the impact of heavier drinking on 10-year CAD risk in a population with high mean alcohol consumption. In a population-based study of 5,769 adults (aged 35 to 75 years) without cardiovascular disease in Switzerland, 1-week alcohol consumption was categorized as 0, 1 to 6, 7 to 13, 14 to 20, 21 to 27, 28 to 34, and > or =35 drinks/week or as nondrinkers (0 drinks/week), moderate (1 to 13 drinks/week), high (14 to 34 drinks/week), and very high (> or =35 drinks/week). Blood pressure and lipids were measured, and 10-year CAD risk was calculated according to the Framingham risk score. Seventy-three percent (n = 4,214) of the participants consumed alcohol; 16% (n = 909) were high drinkers and 2% (n = 119) very high drinkers. In multivariate analysis, increasing alcohol consumption was associated with higher high-density lipoprotein cholesterol (from a mean +/- SE of 1.57 +/- 0.01 mmol/L in nondrinkers to 1.88 +/- 0.03 mmol/L in very high drinkers); triglycerides (1.17 +/- 1.01 to 1.32 +/- 1.05 mmol/L), and systolic and diastolic blood pressure (127.4 +/- 0.4 to 132.2 +/- 1.4 mm Hg and 78.7 +/- 0.3 to 81.7 +/- 0.9 mm Hg, respectively) (all p values for trend <0.001). Ten-year CAD risk increased from 4.31 +/- 0.10% to 4.90 +/- 0.37% (p = 0.03) with alcohol use, with a J-shaped relation. Increasing wine consumption was more related to high-density lipoprotein cholesterol levels, whereas beer and spirits were related to increased triglyceride levels. In conclusion, as measured by 10-year CAD risk, the protective effect of alcohol consumption disappears in very high drinkers, because the beneficial increase in high-density lipoprotein cholesterol is offset by the increases in blood pressure levels.
Resumo:
Introduction: Falls efficacy, defined as confidence in performing activities without falling, is a measure of fear of falling associated with gait impairment, falls and functional decline in frail older people. This relationship has not been well studied in high-functioning older people. Objective: To evaluate the relationship between falls efficacy and gait performance in a cohort of high-functioning older people. Methods: Subjects (N = 864) were a subsample of communitydwelling older people aged 65 to 70 years, enrolled in the "Lc65+" cohort, who completed gait assessment at baseline. Data were collected on demographics, functional, cognitive, affective, and health status. Falls efficacy was assessed using the Falls Efficacy Scale- International (FES-I) that measures confidence in performing 16 activities of daily life (ADL) without falling (score from 16 to 64, higher score indicates lower confidence). Gait parameters were measured over a 20 m walk at preferred gait speed using Physilog, an ambulatory gait monitoring system. Results: Participants (mean age 68.0 ± 1.4 years, 55.0% women) had excellent physical (92.2% independent in basic ADL, mean gait speed 1.13 ± 0.16 m/sec) and cognitive (98.0% with MMSE 024) performance. Nevertheless, 22.1% reported depressive symptoms and 16.1% one or more fall in the previous year. Mean FES-I score was 18.8 ± 4.1. Falls efficacy was associated with gait speed (Spearman rho -0.23, P <.001) and gait variability (Spearman rho 0.10, P = .006), measured by the coefficient of variation of stride velocity. These associations remained in multivariate analysis for both gait speed (adj [beta] coeff: -0.008, 95%CI -0.005 to -0.010, P <.001) and gait variability (adj [beta] coeff 0.024, 95%CI 0.003 to 0.045, P = .023) independent of gender, falls, functional, affective, cognitive, and frailty (Fried's criteria) status. On average, compared to subjects with poor confidence in performing one ADL without falling, those with full confidence had a 0.02 m/sec (2%) faster gait speed and a 2% decrease in gait variability. Conclusion: Even in high-functioning older people, poor falls efficacy is associated with reduced gait speed and stability, independent of health, functional, and frailty status. The direction of this relationship needs to be investigated prospectively to determine causality and design interventions to improve gait performance, reduce fall risk, and prevent functional decline.