20 resultados para linear prediction signal subspace fitting

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Pulmonary hypoplasia is a determinant parameter for extra-uterine life. In the last years, MRI appears as a complement to US in order to evaluate the degree of pulmonary hypoplasia in foetuses with congenital anomalies, by using different methods - fetal lung volumetry (FLV), lung-to-liver signal intensity ratio (LLSIR)-. But until now, information about the correlation between the MRI prediction and the real postnatal outcome is limited. Methods and materials: We retrospectively reviewed the fetal MRI performed at our Institution in the last 8 years and selected the cases with suspicion of fetal pulmonary hypoplasia (n = 30). The pulmonary volumetry data of these foetuses were collected and the lung-to-liver signal intensity ratio (LLSIR) measures performed. These data were compared with those obtained from a control group of 25 foetuses considered as normal at MRI. The data of the study group were also correlated with the autopsy records or the post-natal clinical information of the patients. Results: As expected, the control group showed higher FLV and LLSIR values than the problem group at all gestational ages. Higher values of FLV and LLSIR were associated with a better post-natal outcome. Sensitivity, specificity, positive and negative predictive values and accuracy for the relative LLSIR and the relative FLV showed no significant differences. Conclusion: Our data show that not only the FLV but also the relative LLSIR inform about the degree of fetal lung development. This information may help to predict the fetal outcome and to evaluate the need for neonatal intensive care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As fitness returns during a breeding attempt are context-dependent, parents are predicted to bias their food allocation within a brood from poor towards good condition nestlings when environmental conditions deteriorate. We tested this prediction in the Alpine swift and the European starling, two migratory bird species, by modifying an ultraviolet (UV) visual signal of condition in nestlings and exploring how parents allocate food to their young as the season progresses. We show in both species that: (i) UV light reflected by the body skin of offspring positively correlates with their stature (i.e. body mass and skeletal size) and (ii) parental favouritism towards young with more UV reflective skin gradually increases as the season progresses. Early-breeding parents supplied food preferentially to UV pale (i.e. small stature) nestlings, whereas late-breeding parents favoured UV bright offspring (i.e. large stature). These results emphasize that parents use UV signals of offspring condition to adjust their feeding strategies depending on the ecological context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background/objectives:Bioelectrical impedance analysis (BIA) is used in population and clinical studies as a technique for estimating body composition. Because of significant under-representation in existing literature, we sought to develop and validate predictive equation(s) for BIA for studies in populations of African origin.Subjects/methods:Among five cohorts of the Modeling the Epidemiologic Transition Study, height, weight, waist circumference and body composition, using isotope dilution, were measured in 362 adults, ages 25-45 with mean body mass indexes ranging from 24 to 32. BIA measures of resistance and reactance were measured using tetrapolar placement of electrodes and the same model of analyzer across sites (BIA 101Q, RJL Systems). Multiple linear regression analysis was used to develop equations for predicting fat-free mass (FFM), as measured by isotope dilution; covariates included sex, age, waist, reactance and height(2)/resistance, along with dummy variables for each site. Developed equations were then tested in a validation sample; FFM predicted by previously published equations were tested in the total sample.Results:A site-combined equation and site-specific equations were developed. The mean differences between FFM (reference) and FFM predicted by the study-derived equations were between 0.4 and 0.6âeuro0/00kg (that is, 1% difference between the actual and predicted FFM), and the measured and predicted values were highly correlated. The site-combined equation performed slightly better than the site-specific equations and the previously published equations.Conclusions:Relatively small differences exist between BIA equations to estimate FFM, whether study-derived or published equations, although the site-combined equation performed slightly better than others. The study-derived equations provide an important tool for research in these understudied populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article we present a novel approach for diffusion MRI global tractography. Our formulation models the signal in each voxel as a linear combination of fiber-tract basis func- tions, which consist of a comprehensive set of plausible fiber tracts that are locally compatible with the measured MR signal. This large dictionary of candidate fibers is directly estimated from the data and, subsequently, efficient convex optimization techniques are used for recovering the smallest subset globally best fitting the measured signal. Experimen- tal results conducted on a realistic phantom demonstrate that our approach significantly reduces the computational cost of global tractography while still attaining a reconstruction quality at least as good as the state-of-the-art global methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Escherichia coli-based bioreporters for arsenic detection are typically based on the natural feedback loop that controls ars operon transcription. Feedback loops are known to show a wide range linear response to the detriment of the overall amplification of the incoming signal. While being a favourable feature in controlling arsenic detoxification for the cell, a feedback loop is not necessarily the most optimal for obtaining highest sensitivity and response in a designed cellular reporter for arsenic detection. Here we systematically explore the effects of uncoupling the topology of arsenic sensing circuitry on the developed reporter signal as a function of arsenite concentration input. A model was developed to describe relative ArsR and GFP levels in feedback and uncoupled circuitry, which was used to explore new ArsR-based synthetic circuits. The expression of arsR was then placed under the control of a series of constitutive promoters, which differed in promoter strength, and which could be further modulated by TetR repression. Expression of the reporter gene was maintained under the ArsR-controlled Pars promoter. ArsR expression in the systems was measured by using ArsR-mCherry fusion proteins. We find that stronger constitutive ArsR production decreases arsenite-dependent EGFP output from Pars and vice versa. This leads to a tunable series of arsenite-dependent EGFP outputs in a variety of systematically characterized circuitries. The higher expression levels and sensitivities of the response curves in the uncoupled circuits may be useful for improving field-test assays using arsenic bioreporters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Risks of significant infant drug exposurethrough breastmilk are poorly defined for many drugs, and largescalepopulation data are lacking. We used population pharmacokinetics(PK) modeling to predict fluoxetine exposure levels ofinfants via mother's milk in a simulated population of 1000 motherinfantpairs.METHODS: Using our original data on fluoxetine PK of 25breastfeeding women, a population PK model was developed withNONMEM and parameters, including milk concentrations, wereestimated. An exponential distribution model was used to account forindividual variation. Simulation random and distribution-constrainedassignment of doses, dosing time, feeding intervals and milk volumewas conducted to generate 1000 mother-infant pairs with characteristicssuch as the steady-state serum concentrations (Css) and infantdose relative to the maternal weight-adjusted dose (relative infantdose: RID). Full bioavailability and a conservative point estimate of1-month-old infant CYP2D6 activity to be 20% of the adult value(adjusted by weigth) according to a recent study, were assumed forinfant Css calculations.RESULTS: A linear 2-compartment model was selected as thebest model. Derived parameters, including milk-to-plasma ratios(mean: 0.66; SD: 0.34; range, 0 - 1.1) were consistent with the valuesreported in the literature. The estimated RID was below 10% in >95%of infants. The model predicted median infant-mother Css ratio was0.096 (range 0.035 - 0.25); literature reported mean was 0.07 (range0-0.59). Moreover, the predicted incidence of infant-mother Css ratioof >0.2 was less than 1%.CONCLUSION: Our in silico model prediction is consistent withclinical observations, suggesting that substantial systemic fluoxetineexposure in infants through human milk is rare, but further analysisshould include active metabolites. Our approach may be valid forother drugs. [supported by CIHR and Swiss National Science Foundation(SNSF)]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microtubule plus-end-tracking proteins (+TIPs) specifically localize to the growing plus-ends of microtubules to regulate microtubule dynamics and functions. A large group of +TIPs contain a short linear motif, SXIP, which is essential for them to bind to end-binding proteins (EBs) and target microtubule ends. The SXIP sequence site thus acts as a widespread microtubule tip localization signal (MtLS). Here we have analyzed the sequence-function relationship of a canonical MtLS. Using synthetic peptide arrays on membrane supports, we identified the residue preferences at each amino acid position of the SXIP motif and its surrounding sequence with respect to EB binding. We further developed an assay based on fluorescence polarization to assess the mechanism of the EB-SXIP interaction and to correlate EB binding and microtubule tip tracking of MtLS sequences from different +TIPs. Finally, we investigated the role of phosphorylation in regulating the EB-SXIP interaction. Together, our results define the sequence determinants of a canonical MtLS and provide the experimental data for bioinformatics approaches to carry out genome-wide predictions of novel +TIPs in multiple organisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The relevance of the SYNTAX score for the particular case of patients with acute ST- segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI)  has previously only been studied in the setting of post hoc analysis of large prospective randomized clinical trials. A "real-life" population approach has never been explored before. The aim of this study was to evaluate the impact of the SYNTAX score for the prediction of the myocardial infarction size, estimated by the creatin-kinase (CK) peak value, using the SYNTAX score in patients treated with primary coronary intervention for acute ST-segment elevation myocardial infarction. Methods The primary endpoint of the study was myocardial infarction size as measured by the CK peak value. The SYNTAX score was calculated retrospectively in 253 consecutive patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI) in a large tertiary referral center in Switzerland, between January 2009 and June 2010. Linear regression analysis was performed to compare myocardial infarction size with the SYNTAX score. This same endpoint was then stratified according to SYNTAX score tertiles: low <22 (n=178), intermediate [22-32] (n=60), and high >=33 (n=15). Results There were no significant differences in terms of clinical characteristics between the three groups. When stratified according to the SYNTAX score tertiles, average CK peak values of 1985 (low<22), 3336 (intermediate [22-32]) and 3684 (high>=33) were obtained with a p-value <0.0001. Bartlett's test for equal variances between the three groups was 9.999 (p-value <0.0067). A moderate Pearson product-moment correlation coefficient (r=0.4074) with a high statistical significance level (p-value <0.0001) was found. The coefficient of determination (R^2=0.1660) showed that approximately 17% of the variation of CK peak value (myocardial infarction size) could be explained by the SYNTAX score, i.e. by the coronary disease complexity. Conclusion In an all-comers population, the SYNTAX score is an additional tool in predicting myocardial infarction size in patients treated with primary percutaneous coronary intervention (PPCI). The stratification of patients in different risk groups according to SYNTAX enables to identify a high-risk population that may warrant particular patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To explore whether triaxial accelerometric measurements can be utilized to accurately assess speed and incline of running in free-living conditions. METHODS: Body accelerations during running were recorded at the lower back and at the heel by a portable data logger in 20 human subjects, 10 men, and 10 women. After parameterizing body accelerations, two neural networks were designed to recognize each running pattern and calculate speed and incline. Each subject ran 18 times on outdoor roads at various speeds and inclines; 12 runs were used to calibrate the neural networks whereas the 6 other runs were used to validate the model. RESULTS: A small difference between the estimated and the actual values was observed: the square root of the mean square error (RMSE) was 0.12 m x s(-1) for speed and 0.014 radiant (rad) (or 1.4% in absolute value) for incline. Multiple regression analysis allowed accurate prediction of speed (RMSE = 0.14 m x s(-1)) but not of incline (RMSE = 0.026 rad or 2.6% slope). CONCLUSION: Triaxial accelerometric measurements allows an accurate estimation of speed of running and incline of terrain (the latter with more uncertainty). This will permit the validation of the energetic results generated on the treadmill as applied to more physiological unconstrained running conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microstructure imaging from diffusion magnetic resonance (MR) data represents an invaluable tool to study non-invasively the morphology of tissues and to provide a biological insight into their microstructural organization. In recent years, a variety of biophysical models have been proposed to associate particular patterns observed in the measured signal with specific microstructural properties of the neuronal tissue, such as axon diameter and fiber density. Despite very appealing results showing that the estimated microstructure indices agree very well with histological examinations, existing techniques require computationally very expensive non-linear procedures to fit the models to the data which, in practice, demand the use of powerful computer clusters for large-scale applications. In this work, we present a general framework for Accelerated Microstructure Imaging via Convex Optimization (AMICO) and show how to re-formulate this class of techniques as convenient linear systems which, then, can be efficiently solved using very fast algorithms. We demonstrate this linearization of the fitting problem for two specific models, i.e. ActiveAx and NODDI, providing a very attractive alternative for parameter estimation in those techniques; however, the AMICO framework is general and flexible enough to work also for the wider space of microstructure imaging methods. Results demonstrate that AMICO represents an effective means to accelerate the fit of existing techniques drastically (up to four orders of magnitude faster) while preserving accuracy and precision in the estimated model parameters (correlation above 0.9). We believe that the availability of such ultrafast algorithms will help to accelerate the spread of microstructure imaging to larger cohorts of patients and to study a wider spectrum of neurological disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MicroRNAs (miRs) are involved in the pathogenesis of several neoplasms; however, there are no data on their expression patterns and possible roles in adrenocortical tumors. Our objective was to study adrenocortical tumors by an integrative bioinformatics analysis involving miR and transcriptomics profiling, pathway analysis, and a novel, tissue-specific miR target prediction approach. Thirty-six tissue samples including normal adrenocortical tissues, benign adenomas, and adrenocortical carcinomas (ACC) were studied by simultaneous miR and mRNA profiling. A novel data-processing software was used to identify all predicted miR-mRNA interactions retrieved from PicTar, TargetScan, and miRBase. Tissue-specific target prediction was achieved by filtering out mRNAs with undetectable expression and searching for mRNA targets with inverse expression alterations as their regulatory miRs. Target sets and significant microarray data were subjected to Ingenuity Pathway Analysis. Six miRs with significantly different expression were found. miR-184 and miR-503 showed significantly higher, whereas miR-511 and miR-214 showed significantly lower expression in ACCs than in other groups. Expression of miR-210 was significantly lower in cortisol-secreting adenomas than in ACCs. By calculating the difference between dCT(miR-511) and dCT(miR-503) (delta cycle threshold), ACCs could be distinguished from benign adenomas with high sensitivity and specificity. Pathway analysis revealed the possible involvement of G2/M checkpoint damage in ACC pathogenesis. To our knowledge, this is the first report describing miR expression patterns and pathway analysis in sporadic adrenocortical tumors. miR biomarkers may be helpful for the diagnosis of adrenocortical malignancy. This tissue-specific target prediction approach may be used in other tumors too.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: in a retrospective study, attempts have been made to identify individual organ-dysfunction risk profiles influencing the outcome after surgery for ruptured abdominal aortic aneurysms. METHODS: out of 235 patients undergoing graft replacement for abdominal aortic aneurysms, 57 (53 men, four women, mean age 72 years [s.d. 8.8]) were treated for ruptured aneurysms in a 3-year period. Forty-eight preoperative, 13 intraoperative and 34 postoperative variables were evaluated statistically. A simple multi-organ dysfunction (MOD) score was adopted. RESULTS: the perioperative mortality was 32%. Three patients died intraoperatively, four within 48 h and 11 died later. A significant influence for pre-existing risk factors was identified only for cardiovascular diseases. Multiple linear-regression analysis indicated that a haemoglobin <90 g/l, systolic blood pressure <80 mmHg and ECG signs of ischaemia at admission were highly significant risk factors. The cause of death for patients, who died more than 48 h postoperatively, was mainly MOD. All patients with a MOD score >/=4 died (n=7). These patients required 27% of the intensive-care unit (ICU) days of all patients and 72% of the ICU days of the non-survivors. CONCLUSION: patients with ruptured aortic aneurysms from treatment should not be excluded. However, a physiological scoring system after 48 h appears justifiable in order to decide on the appropriateness of continual ICU support.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: Total imatinib concentrations are currently measured for the therapeutic drug monitoring of imatinib, whereas only free drug equilibrates with cells for pharmacological action. Due to technical and cost limitations, routine measurement of free concentrations is generally not performed. In this study, free and total imatinib concentrations were measured to establish a model allowing the confident prediction of imatinib free concentrations based on total concentrations and plasma proteins measurements. METHODS: One hundred and fifty total and free plasma concentrations of imatinib were measured in 49 patients with gastrointestinal stromal tumours. A population pharmacokinetic model was built up to characterize mean total and free concentrations with inter-patient and intrapatient variability, while taking into account α1 -acid glycoprotein (AGP) and human serum albumin (HSA) concentrations, in addition to other demographic and environmental covariates. RESULTS: A one compartment model with first order absorption was used to characterize total and free imatinib concentrations. Only AGP influenced imatinib total clearance. Imatinib free concentrations were best predicted using a non-linear binding model to AGP, with a dissociation constant Kd of 319 ng ml(-1) , assuming a 1:1 molar binding ratio. The addition of HSA in the equation did not improve the prediction of imatinib unbound concentrations. CONCLUSION: Although free concentration monitoring is probably more appropriate than total concentrations, it requires an additional ultrafiltration step and sensitive analytical technology, not always available in clinical laboratories. The model proposed might represent a convenient approach to estimate imatinib free concentrations. However, therapeutic ranges for free imatinib concentrations remain to be established before it enters into routine practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Activity monitors based on accelerometry are used to predict the speed and energy cost of walking at 0% slope, but not at other inclinations. Parallel measurements of body accelerations and altitude variation were studied to determine whether walking speed prediction could be improved. Fourteen subjects walked twice along a 1.3 km circuit with substantial slope variations (-17% to +17%). The parameters recorded were body acceleration using a uni-axial accelerometer, altitude variation using differential barometry, and walking speed using satellite positioning (DGPS). Linear regressions were calculated between acceleration and walking speed, and between acceleration/altitude and walking speed. These predictive models, calculated using the data from the first circuit run, were used to predict speed during the second circuit. Finally the predicted velocity was compared with the measured one. The result was that acceleration alone failed to predict speed (mean r = 0.4). Adding altitude variation improved the prediction (mean r = 0.7). With regard to the altitude/acceleration-speed relationship, substantial inter-individual variation was found. It is concluded that accelerometry, combined with altitude measurement, can assess position variations of humans provided inter-individual variation is taken into account. It is also confirmed that DGPS can be used for outdoor walking speed measurements, opening up new perspectives in the field of biomechanics.