21 resultados para iodine-125

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copper-67 has comparable beta-particle emissions to that of 131I, but it displays more favorable gamma emission characteristics for application in radioimmunotherapy (RIT). This study investigates the potential of 67Cu-labeled monoclonal antibody (MAb) 35 for RIT of colorectal carcinoma. METHODS: Biokinetics of simultaneously injected 67Cu- and 125I-labeled MAb35 were studied in six patients scheduled for surgery of primary colorectal cancer. RESULTS: Whole-body clearance (T 1/2) of 67Cu, estimated from sequential anterior and posterior whole-body scans and corrected for decay of 67Cu, was 41 hr. Serum clearance of 67Cu was faster (27.41 hr) than that of 125I (38.33 hr). Mean tumor uptake of the 67Cu-labeled compound (0.0133% ID/g) exceeded that of 125I (0.0095% ID/g), and tumor-to-blood ratios were higher for 67Cu than for 125I, with averages of 6.07 and 2.41, respectively. The average 67Cu/125I ratio was 1.9 for tumor uptake, 0.7 for blood and 2.6 for tumor-to-blood ratios. Nonspecific liver uptake of 67Cu as calculated from whole-body scans was high in four patients, up to 25% of residual whole-body activity at 48 hr, but did not increase with time. We also observed some nonspecific bowel activity, as well as moderate to high uptake in benign polyps. CONCLUSION: Copper-67-labeled MAb35 is more favorable than its radioiodine-labeled counterpart for RIT of colorectal carcinoma due to higher tumor-to-blood ratios, but the problem of nonspecific liver and bowel uptake must first be overcome. The absolute accumulation of activity in tumor remains low, however, so the probability of cure with this compound alone is questionable. The use of 67Cu as one component of a multimodality adjuvant treatment seems to remain the most appropriate application for RIT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The risk/benefit profile of intravitreal melphalan injection for treatment of active vitreous seeds in retinoblastoma remains uncertain. We report clinical and electroretinography results after 6 months of one patient who has shown a favorable initial clinical response to intravitreal melphalan injections for treatment of refractory vitreous seeds. METHODS: Clinical case report. PATIENT: The patient presented at age 17 months with bilateral retinoblastoma [OD: International Classification (ICRB) group E, Reese-Ellsworth (R-E) class Vb; OS: ICRB D, R-E Vb] with no known prior family history. The right eye was enucleated primarily. The patient received systemic chemotherapy and extensive local treatment to the left eye. Ten months later, she presented with recurrent disease, including fine, diffuse vitreous seeds. Tumor control was established with intra-arterial chemotherapy and local treatment. Subsequent recurrence was treated with further intra-arterial chemotherapy, local treatment, and plaque radiotherapy with iodine-125. Persistent free-floating spherical vitreous seeds were treated with 4 cycles of intravitreal melphalan injection via the pars plana, with doses of 30, 30, 30, and 20 μg. RESULTS: After 6 months of follow-up, the left eye remained free of active tumor. Visual acuity was 20/40. Photopic ERGs amplitudes were unchanged compared with those recorded prior to the intravitreal injection treatments. CONCLUSIONS: Intravitreal melphalan injection for refractory spherical vitreous seeds of retinoblastoma with favorable tumor response is compatible with good central visual acuity and preservation of retinal function as indicated by photopic ERG recordings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biodistribution and tumor uptake of a chimeric human-mouse monoclonal antibody (MAb) and the original mouse MAb have been comparatively studied. METHODS: Eighteen patients with suspected colorectal cancer scheduled for surgery underwent immunoscintigraphy with 123I-labeled chimeric anti-CEA MAb. Iodine-125 and 131I trace-labeled chimeric and original mouse MAb were simultaneously injected for biodistribution studies. RESULTS: Similar serum kinetics and a low immunogenicity were observed for both antibodies. Mean binding capacity to CEA measured in PBS after radiolabeling was identical for both MAbs and it was slightly decreased when measured in serum 1-4 hr after injection. Radiochromatograms of patients sera showed immune complex formation related to the amount of circulating CEA. Postoperative ex vivo radioactivity counting in tissue samples revealed similar antibody distributions with notably similar antibody uptakes in tumors. High tumor uptakes (between 0.02 to 0.06% injected dose per g) were observed in 3 of 13 patients operated for primary or metastatic colorectal cancer. CONCLUSION: In this dual-label technique, the radioiodinated anti-CEA IgG4 chimeric MAb and the original mouse IgG1 MAb were shown to have very similar behavior in colorectal cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preparation of a novel radioiodination reagent, the (aminooxy)acetyl derivative of (p-[125]-iodophenyl)ethylamine, is described. Conventional radioiodination of proteins involves the formation of iodotyrosine residues, but for in vivo applications such as thyroid or stomach immunoscintigraphy, the susceptibility of these residues to tissue dehalogenases constitutes a serious disadvantage. Using our new compound, which has a particularly nonreactive aromatic ring, we confirm and extend studies published by other workers indicating the much greater in vivo stability of iodophenyl compounds compared to the more conventional iodophenolic ones. In addition, the aminooxy group of our reagent gives a stable and specific linkage to aldehyde groups formed by periodate oxidation on the sugar moiety of antibody molecules. In vitro, favorable binding activity and high stability was obtained with a (([125I]iodoaryl)amino)oxy labeled monoclonal antibody directed against carcinoembryonic antigen. In vivo, using paired labeling experiments in nude mice bearing colon carcinoma xenografts, the (([125I]iodoaryl)amino)oxy-MAb (MAb = monoclonal antibody) was compared with the same MAb 131I-labeled by conventional chloramine-T method. Tumor 125I concentration of (arylamino)oxy MAb (measured as percent injected dose per gram) was significantly higher as compared to values obtained with a conventionally labeled 131I antibody. Additionally, thyroid uptake, an indicator of iodine release from the antibody, was up to 25 times lower after injection of 125I-MAb obtained by the new method as compared to the conventionally iodinated 131I-MAb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is debated whether chronic hypertension increases the risk of cardiovascular incidents during anaesthesia. We studied all elective surgical operations performed in adults under general or regional anaesthesia between 2000 and 2004, in 24 hospitals collecting computerised clinical data on all anaesthetics since 1996. The focus was on cardiovascular incidents, though other anaesthesia-related incidents were also evaluated. Among 124,939 interventions, 27,881 (22%) were performed in hypertensive patients. At least one cardiovascular incident occurred in 7549 interventions (6% (95% CI 5.9-6.2%)). The average adjusted odds ratio of cardiovascular risk for chronic hypertension was 1.38 (95% CI 1.27-1.49). However, across hospitals, adjusted odd ratios varied from 0.41 up to 2.25. Hypertension did not increase the risk of other incidents. Hypertensive patients are still at risk of intra-operative cardiovascular incidents, while risk heterogeneity across hospitals, despite taking account of casemix and hospital characteristics, suggests variations in anaesthetic practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental studies in nude mice with human colon-carcinoma grafts demonstrated the therapeutic efficiency of F(ab')2 fragments to carcinoembryonic antigen (CEA) labeled with a high dose of 131Iodine. A phase I/II study was designed to determine the maximum tolerated dose of 131I-labeled F(ab')2 fragments (131I-F(ab')2) from anti-CEA monoclonal antibody F6, its limiting organ toxicity and tumor uptake. Ten patients with non-resectable liver metastases from colorectal cancer (9 detected by CT scan and 1 by laparotomy) were treated with 131I-F(ab')2, doses ranging from 87 mCi to 300 mCi for the first 5 patients, with a constant 300-mCi dose for the last 5 patients. For all the patients, autologous bone marrow was harvested and stored before treatment. Circulating CEA ranged from 2 to 126 ng/ml. No severe adverse events were observed during or immediately following infusion of therapeutic doses. The 9 patients with radiologic evidence of liver metastases showed uptake of 131I-F(ab')2 in the metastases, as observed by single-photon-emission tomography. The only toxicity was hematologic, and no severe aplasia was observed when up to 250 mCi was infused. At the 300-mCi dose, 5 out of 6 patients presented grade-3 or -4 hematologic toxicity, with a nadir for neutrophils and thrombocytes ranging from 25 to 35 days after infusion. In these 5 cases, bone marrow was re-infused. No clinical complications were observed during aplasia. The tumor response could be evaluated in 9 out of 10 patients. One patient showed a partial response of one small liver metastasis (2 cm in diameter) and a stable evolution of the other metastases, 2 patients had stable disease, and 6 showed tumor progression at the time of evaluation (2 or 3 months after injection) by CT scan. This phase-I/II study demonstrated that a dose of 300 mCi of 131I-F(ab')2 from the anti-CEA Mab F6 is well tolerated with bone-marrow rescue, whereas a dose of 200 mCi can be infused without severe bone-marrow toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of radioimmunotherapy (RIT) with radiolabeled anti-carcinoembryonic antigen antibodies after complete resection of liver metastases (LM) from colorectal cancer. Patients and Methods: Twenty-two patients planned for surgery of one to four LM received a preoperative diagnostic dose of a 131I-F(ab')2-labeled anti-carcinoembryonic antigen monoclonal antibody F6 (8-10 mCi/5 mg). 131I-F(ab')2 uptake was analyzed using direct radioactivity counting, and tumor-to-normal liver ratios were recorded. Ten patients with tumor-to-normal liver ratios of >5 and three others were treated with a therapeutic injection [180-200 mCi 131I/50 mg F(ab')2] 30 to 64 days after surgery. RESULTS: Median 131I-F(ab')2 immunoreactivity in patient serum remained at 91% of initial values for up to 96 hours after injection. The main and dose-limiting-toxicity was hematologic, with 92% and 85% grades 3 to 4 neutropenia and thrombocytopenia, respectively. Complete spontaneous recovery occurred in all patients. No human anti-mouse antibody response was observed after the diagnosis dose; however, 10 of the 13 treated patients developed human anti-mouse antibody approximately 3 months later. Two treated patients presented extrahepatic metastases at the time of RIT (one bone and one abdominal node) and two relapsed within 3 months of RIT (one in the lung and the other in the liver). Two patients are still alive, and one of these is disease-free at 93 months after resection. At a median follow-up of 127 months, the median disease-free survival is 12 months and the median overall survival is 50 months. CONCLUSION: RIT is feasible in an adjuvant setting after complete resection of LM from colorectal cancer and should be considered for future trials, possibly in combination with chemotherapy, because of the generally poor prognosis of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During one week, beginning 18 days after transplantation, nude mice bearing human colon carcinoma ranging from 115 to 943 mm3 (mean 335 mm3) were treated by repeated intravenous injections of either iodine-131-(131I) labeled intact antibodies or 131I-labeled corresponding F(ab')2 fragments of a pool of four monoclonal antibodies (MAbs) directed against distinct epitopes of carcinoembryonic antigen (CEA). Complete tumor remission was observed in 8 of 10 mice after therapy with F(ab')2 and 6 of the animals survived 10 mo in good health. In contrast, after treatment with intact MAbs, tumors relapsed in 7 of 8 mice after remission periods of 1 to 3.5 mo despite the fact that body weight loss and depression of peripheral white blood cells, symptoms of radiation toxicity, and the calculated radiation doses for liver, spleen, bone, and blood were increased or equal in these animals as compared to mice treated with F(ab')2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intratumoural (i.t.) injection of radio-iododeoxyuridine (IdUrd), a thymidine (dThd) analogue, is envisaged for targeted Auger electron- or beta-radiation therapy of glioblastoma. Here, biodistribution of [(125)I]IdUrd was evaluated 5 hr after i.t. injection in subcutaneous human glioblastoma xenografts LN229 after different intravenous (i.v.) pretreatments with fluorodeoxyuridine (FdUrd). FdUrd is known to block de novo dThd synthesis, thus favouring DNA incorporation of radio-IdUrd. Results showed that pretreatment with 2 mg/kg FdUrd i.v. in 2 fractions 0.5 hr and 1 hr before injection of radio-IdUrd resulted in a mean tumour uptake of 19.8% of injected dose (% ID), representing 65.3% ID/g for tumours of approx. 0.35 g. Tumour uptake of radio-IdUrd in non-pretreated mice was only 4.1% ID. Very low uptake was observed in normal nondividing and dividing tissues with a maximum concentration of 2.9% ID/g measured in spleen. Pretreatment with a higher dose of FdUrd of 10 mg/kg prolonged the increased tumour uptake of radio-IdUrd up to 5 hr. A competition experiment was performed in FdUrd pretreated mice using i.t. co-injection of excess dThd that resulted in very low tumour retention of [(125)I]IdUrd. DNA isolation experiments showed that in the mean >95% of tumour (125)I activity was incorporated in DNA. In conclusion, these results show that close to 20% ID of radio-IdUrd injected i.t. was incorporated in tumour DNA after i.v. pretreatment with clinically relevant doses of FdUrd and that this approach may be further exploited for diffusion and therapy studies with Auger electron- and/or beta-radiation-emitting radio-IdUrd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective treatment of ovarian cancer depends upon the early detection of the malignancy. Here, we report on the development of a new nanostructured immunosensor for early detection of cancer antigen 125 (CA-125). A gold electrode was modified with mercaptopropionic acid (MPA), and then consecutively conjugated with silica coated gold nanoparticles (AuNP@SiO2), CdSe quantum dots (QDs) and anti-CA-125 monoclonal antibody (mAb). The engineered MPA|AuNP@SiO2|QD|mAb immunosensor was characterised using transmission electron microscopy (TEM), atomic force microscopy (AFM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Successive conjugation of AuNP@SiO2, CdSe QD and anti-CA-125 mAb onto the gold electrode resulted in sensitive detection of CA-125 with a limit of detection (LOD) of 0.0016 U mL(-1) and a linear detection range (LDR) of 0-0.1 U mL(-1). Based on the high sensitivity and specificity of the immunosensor, we propose this highly stable and reproducible biosensor for the early detection of CA-125.