62 resultados para intravascular hemolysis
em Université de Lausanne, Switzerland
Resumo:
Purpose: The purpose of this study was to compare the plaque morphology between coronary and peripheral arteries using intravascular ultrasound (IVUS). Methods: IVUS was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Results: Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P=NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P=0.02) was observed in all arteries. Compared to coronary arteries, VH-FA was less frequently observed in renal (P<0.001) and iliac arteries (P<0.006), while VH-PIT and VH-FC were prevalent in both of these peripheral arteries. Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary, carotid, and renal arteries compared to those with intermediate/negative remodeling (all P<0.01). There was positive relationship between RI and percent necrotic core area in all four arteries. Conclusions: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries. In contrast, the associations of remodeling mode with plaque phenotype and composition were similar among the various arterial beds.
Resumo:
Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.
Resumo:
PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.
Resumo:
The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.
Resumo:
Les infections liées aux accès vasculaires sont à l'origine d'une proportion importante des infections nosocomiales. Elles comprennent leur colonisation par des micro-organismes, les infections du site d'insertion et les bactériémies et fongémies qui leur sont associées ou attribuées. Une bactériémie complique l'insertion de 3 à 5 % des voies veineuses, correspondant à une incidence de 2 à 14 épisodes pour 1000 jourcathéters. Cette proportion ne représente toutefois que la partie visible de l'iceberg puisque la plupart des épisodes de sepsis clinique sans foyer infectieux associé sont également considérés comme liés aux accès vasculaires. Après un rappel de leur physiopathologie, cet article passe en revue les éléments importants pour leur prévention, y compris ceux concernant l'utilisation de cathéters imprégnés de désinfectants ou d'antibiotiques. Pour terminer, nous discutons en détail les stratégies préventives globales. Fondées sur la prise en compte d'un ensemble d'éléments spécifiques, ces approches sont centrées sur l'éducation du personnel au respect des règles d'hygiène de base et sur l'introduction de recommandations précises pour l'insertion et l'utilisation des accès vasculaires.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
In three-dimensional (3D) coronary magnetic resonance angiography (MRA), the in-flow contrast between the coronary blood and the surrounding myocardium is attenuated as compared to thin-slab two-dimensional (2D) techniques. The application of a gadolinium (Gd)-based intravascular contrast agent may provide an additional source of signal and contrast by reducing T(1blood) and supporting the visualization of more distal or branching segments of the coronary arterial tree. In six healthy adults, the left coronary artery (LCA) system was imaged pre- and postcontrast with a 0.075-mmol/kg bodyweight dose of the intravascular contrast agent B-22956. For imaging, an optimized free-breathing, navigator-gated and -corrected 3D inversion recovery (IR) sequence was used. For comparison, state-of-the-art baseline 3D coronary MRA with T(2) preparation for non-exogenous contrast enhancement was acquired. The combination of IR 3D coronary MRA, sophisticated navigator technology, and B-22956 allowed for an extensive visualization of the LCA system. Postcontrast, a significant increase in both the signal-to-noise ratio (SNR; 46%, P < 0.05) and contrast-to-noise ratio (CNR; 160%, P < 0.01) was observed, while vessel sharpness of the left anterior descending (LAD) artery and the left coronary circumflex (LCX) were improved by 20% (P < 0.05) and 18% (P < 0.05), respectively.
Resumo:
Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.
Resumo:
INTRODUCTION: to assess the outcome of endovascular aortic aneurysm repair (EVAR) using intravascular ultrasound (IVUS) without angiography. MATERIALS/METHODS: eighty consecutive patients (median age 69 years (range 25-90): male 72 (90%), female 8 (10%)) underwent endovascular aneurysm repair (AAA 68 (85%), TAA 12 (15%)) using either angiography in 31/80 patients (39%) or IVUS in 49/80 patients (61%) in accordance to the surgeons preference. RESULTS: hospital mortality was 2/80 (3%), 1/68 for AAA (2%), 1/12 for TAA (8%), 2/31 for angiography (7%), and 0/49 for IVUS (0.0%: NS). Median quantity of contrast medium was 190 ml (range: 20-350) for angiography versus 0 ml for IVUS (p<0.01). Median X-ray exposure time 24 min (range 9-65 min) versus 8 min (range 0-60 min) for IVUS (p<0.05). No coverage of renal or suprarenal artery orifices occurred in either group. Conversion to open surgery was necessary in 4/80 patients (5%), 1/31 for angiography (3%) and 3/49 patients for IVUS (6%: NS). Early endoleaks were observed in 13/80 patients (16%): 8/31 patients for angiography (26%) versus 5/49 for IVUS (10%: p<0.05): 5/13 endoleaks resolved spontaneously (39%) whereas 8/13 (61%) required additional procedures. CONCLUSIONS: IVUS is a reliable tool for EVAR. In most cases, perprocedural angiography is not necessary.
Resumo:
PURPOSE: To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND METHODS: Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA. RESULTS: No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA: 6.05 min; 49% vs. WH-CMRA: 5.51 min; 54%, both P = NS). CONCLUSION: Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.
Resumo:
PURPOSE: To evaluate gadocoletic acid (B-22956), a gadolinium-based paramagnetic blood pool agent, for contrast-enhanced coronary magnetic resonance angiography (MRA) in a Phase I clinical trial, and to compare the findings with those obtained using a standard noncontrast T2 preparation sequence. MATERIALS AND METHODS: The left coronary system was imaged in 12 healthy volunteers before B-22956 application and 5 (N = 11) and 45 (N = 7) minutes after application of 0.075 mmol/kg of body weight (BW) of B-22956. Additionally, imaging of the right coronary system was performed 23 minutes after B-22956 application (N = 6). A three-dimensional gradient echo sequence with T2 preparation (precontrast) or inversion recovery (IR) pulse (postcontrast) with real-time navigator correction was used. Assessment of the left and right coronary systems was performed qualitatively (a 4-point visual score for image quality) and quantitatively in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, visible vessel length, maximal luminal diameter, and the number of visible side branches. RESULTS: Significant (P < 0.01) increases in SNR (+42%) and CNR (+86%) were noted five minutes after B-22956 application, compared to precontrast T2 preparation values. A significant increase in CNR (+40%, P < 0.05) was also noted 45 minutes postcontrast. Vessels (left anterior descending artery (LAD), left coronary circumflex (LCx), and right coronary artery (RCA)) were also significantly (P < 0.05) sharper on postcontrast images. Significant increases in vessel length were noted for the LAD (P < 0.05) and LCx and RCA (both P < 0.01), while significantly more side branches were noted for the LAD and RCA (both P < 0.05) when compared to precontrast T2 preparation values. CONCLUSION: The use of the intravascular contrast agent B-22956 substantially improves both objective and subjective parameters of image quality on high-resolution three-dimensional coronary MRA. The increase in SNR, CNR, and vessel sharpness minimizes current limitations of coronary artery visualization with high-resolution coronary MRA.
Resumo:
INTRODUCTION: Mycobacterium tuberculosis may cause a large variety of clinical presentations due to its ability to disseminate by contiguity or hematogenously. Tuberculosis may remain undiagnosed for years due to the chronic course of the disease, with potentially life-threatening long-term complications. CASE PRESENTATION: In this case report, we describe a tuberculous aortic graft infection in a 72-year-old man documented by polymerase chain reaction and cultures. The patient presented with three episodes of hemoptysis following a remote history of miliary tuberculosis. The infection was treated by graft replacement and prolonged antimycobacterial therapy. CONCLUSION: Tuberculous infection of a vascular graft is an uncommon complication, but should be considered in patients with an intravascular device and a history of previous tuberculosis, especially when hematogenous spread may have occurred a few months after surgery, or when an active mycobacterial infection is present in close proximity to the graft.
Resumo:
INTRODUCTION: Solid tumors are known to have an abnormal vasculature that limits the distribution of chemotherapy. We have recently shown that tumor vessel modulation by low-dose photodynamic therapy (L-PDT) could improve the uptake of macromolecular chemotherapeutic agents such as liposomal doxorubicin (Liporubicin) administered subsequently. However, how this occurs is unknown. Convection, the main mechanism for drug transport between the intravascular and extravascular spaces, is mostly related to interstitial fluid pressure (IFP) and tumor blood flow (TBF). Here, we determined the changes of tumor and surrounding lung IFP and TBF before, during, and after vascular L-PDT. We also evaluated the effect of these changes on the distribution of Liporubicin administered intravenously (IV) in a lung sarcoma metastasis model. MATERIALS AND METHODS: A syngeneic methylcholanthrene-induced sarcoma cell line was implanted subpleurally in the lung of Fischer rats. Tumor/surrounding lung IFP and TBF changes induced by L-PDT were determined using the wick-in-needle technique and laser Doppler flowmetry, respectively. The spatial distribution of Liporubicin in tumor and lung tissues following IV drug administration was then assessed in L-PDT-pretreated animals and controls (no L-PDT) by epifluorescence microscopy. RESULTS: L-PDT significantly decreased tumor but not lung IFP compared to controls (no L-PDT) without affecting TBF. These conditions were associated with a significant improvement in Liporubicin distribution in tumor tissues compared to controls (P < .05). DISCUSSION: L-PDT specifically enhanced convection in blood vessels of tumor but not of normal lung tissue, which was associated with a significant improvement of Liporubicin distribution in tumors compared to controls.