313 resultados para intraocular prosthesis

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the efficacy of first-line chemotherapy (CT) in preventing external-beam radiotherapy (EBR) and/or enucleation in patients with retinoblastoma (Rbl). PATIENTS AND METHODS: Twenty-four patients with newly diagnosed unilateral or bilateral Rbl received CT associated with local treatment (LT). Two to five courses of etoposide and carboplatin were administered at 3- to 4-week intervals, depending on tumor response, and were completed each time by LT. RESULTS: Tumor response was observed in all eyes. Twenty-one of 24 patients showed a complete response (CR) that persisted at a median follow-up (FU) of 31 months (range, 4 to 41 months). Among the three patients who relapsed, two were lost to FU and one died of progressive disease. CR was achieved by CT and LT alone in 15 (71.4%) of 21 patients with less advanced disease (groups I to III). Six other patients with advanced disease (groups IV and V) experienced treatment failure and needed salvage treatment by EBR and/or enucleation. The difference between the two patient groups with regard to disease stage was statistically significant (P <.0001). EBR could be avoided in 13 (68.4%) of 19 patients, who presented with groups I to III (15 eyes) and group V (one eye) disease, whereas enucleation could be avoided in only two (40%) of five. CONCLUSION: CT combined with intensive LT is effective in patients with groups I to III Rbl, permitting the avoidance of EBR in the majority of these young children and, thus, reducing the risk of long-term sequelae. This is in contrast with the disappointing results for patients with groups IV and V Rbl, in whom EBR and/or enucleation was needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Extraskeletal myxoid chondrosarcoma (EMC) is a rare soft tissue tumour with a high risk for local recurrence and metastases. While this entity is resistant to radio- or chemo-therapy, wide resection remains the treatment of choice. Case report: A 60 year old man presented to our service with a large mass in his right thigh, slowly evolving over the past 7 years. His main complaint was the volume of his thigh. Imaging showed a 23x13x14 cm tumour in the quadriceps, eroding the cortical bone and with potential contamination of the knee joint. The risk of a pathological fracture was estimated considerable. A CT-guided core-needle biopsy revealed a FNCLCC grade 2 EMC. A thoraco-abdominal CT scan showed multiple pulmonary metastases. Due to the palliative situation with a very slow disease progression, a wide extraarticular resection of the distal femur and reconstruction with a megaprosthesis were performed. Extensive skin necrosis necessitated three revision procedures for débridement and confection of a pediculated lateral gastrocnemius muscle flap. No complementary treatment was possible for the pulmonary metastases. At 18 months follow-up, he walked without crutches, was able to do his activities of daily living. He was painfree and highly satisfied with the result. During the follow-up, slow progression of the pulmonary metastases was noted, which remained asymptomatic. Conclusion: Extraskeletal myxoid chondrosarcoma is a rare soft tissue tumour, and wide excision remains the treatment of choice. Whenever possible, limb salvage should be proposed to preserve function and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Persisting metallic intraocular foreign bodies (IOFB) with a ferrous content have been associated with ocular siderosis and retinal degeneration. We describe two patients in whom a metallic IOFB containing iron was left embedded for many years in the choroid and sclera after having penetrated through the vitreous and the retina. HISTORY AND SIGNS: Two male patients, aged 41 and 48 years, presented with a metallic IOFB sustained during a work accident involving metal tools. THERAPY AND OUTCOME: For the first patient it was deemed unwise to operate, as the IOFB was also lodged very deeply in the choroid and sclera in the inferior temporal quadrant. The second patient underwent pars plana vitrectomy, but the IOFB could not be removed surgically as it was too deeply embedded in the sclera and choroid. After a period of 6 years (Case 1) and 4 years (Case 2) of follow-up, visual acuity remained at 1.0 and the IOFB was encased in a fibrotic capsule in both cases. Full-field and multifocal electroretinograms showed an inter-ocular asymmetry at baseline, which remained stable during the follow-up. CONCLUSIONS: Ocular siderosis may not develop in patients with a deeply embedded metallic IOFB. Regular monitoring of both visual function and the electroretinogram is mandatory when the IOFB is left inside the eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intraocular gas bubbles expand as patients move up to higher altitude. This may cause an acute intraocular pressure (IOP) rise with associated vascular obstructions and visual loss. MATERIALS AND METHODS: Two pseudophakic patients underwent a pars plana vitrectomy and 23% SF6 gas tamponade for a pseudophakic retinal detachment. During the immediate post-operative phase, the patients travelled daily up to their domicile, which was situated approximately 600 m higher than the level where they had been operated on. These travels were always without any pain or visual loss. However 1 week after surgery both patients developed severe ocular pain, and one patient had complete temporary loss of vision after ascending to altitude levels, which had previously presented no problem. Both episodes occurred in parallel with a change in barometric pressure. RESULTS: Treatment with acetazolamide reduced the increased IOP to normal levels, and visual acuity recovered. CONCLUSIONS: Although the post-operative size of an intraocular gas bubble decreases progressively over time, problems with bubble expansion may still occur even at a late stage if meteorological factors, that may increase the bubble size, change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cataract surgery is often performed in patients suffering from associated pathologies. Our goal is to develop a biodegradable drug delivery system (DDS) combined with the artificial intraocular lens (IOL). DDS were manufactured using poly(D,L-lactide-co-glycolide), or PLGA, and were loaded with triamcinolone acetonide (TA). The loading capacity was approximately 1050 microg of TA per DDS. The higher the molecular weight of PLGA (34,000, 48,000 and 80,000Da), the slower was the release of TA in vitro. Cataract surgery was performed on the right eye of rabbits. IOL was inserted with (i) no DDS, (ii) unloaded DDS PLGA48000, (iii) one loaded DDS PLGA48000, (iv) two loaded DDS. The number of inflammatory cells and the protein concentration were measured in the aqueous humor (AH). Unloaded DDS showed good ocular biocompatibility. One DDS PLGA48000 loaded with TA significantly reduced postoperative ocular inflammation. Two loaded DDS PLGA48000 was even more effective in inhibiting such inflammation. On long-term observation (days 63 and 84), reduction of inflammation could be obtained by insertion of one DDS PLGA48000 and a second DDS PLGA80000. Therefore, our "all in one" system is very promising since it could replace oral treatment and reduce the number of intraocular injections

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the mechanisms and treatment of ocular hypertension in patients with thyroid-associated orbitopathy and to differenciate it from glaucomatous damage. DESIGN: Three case reports. METHODS: Retrospective review of clinical findings, course, and treatment of the three patients. RESULTS: Elevated intraocular pressure in thyroid-associated orbitopathy observed in the three cases may involve different physiopathological abnormalities such as disturbances of venous circulation, compression by infiltrative muscles, and long corticosteroid use. In the first two cases, defects demonstrated in the perimetry are in consistent with glaucomatous damage. In the third case, visual field abnormalities may be compatible with a glaucomatous disease, but all defects resolved after therapy. Treatement was of the greatest difficulty for the three cases, associating antiglaucomatous medication, steroids, orbital radiotherapy, orbital decompression and extraocular muscle surgery. Intraocular pressure was controlled in all cases. CONCLUSIONS: Elevated intraocular pressure in thyroid-associated orbitopathy is distinguished from glaucomatous disease by its physiopathological mechanisms, clinical course, visual field defects, and treatment. The management of this hypertension is closely related to the treatment of dysthyroid orbitopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aims: To evaluate multifocal intraocular lens (MIOL) implantation in children. Methods: This is a retrospective study evaluating refractive, visual and safety results of MIOL in pediatric cataract surgery. Average follow-up was 25.73 ± 10.5 months. Surgery included 12 o'clock clear corneal incision, anterior capsulorhexis, lens material aspiration and MIOL implantation (SN6AD3; Alcon). Results: We included 34 cataract eyes of 26 pediatric patients aged 2-15 years, of which 14 (54%) were unilateral. Best near visual acuity (BNVA) and best distance visual acuity (BDVA) improved significantly in 100% of eyes (p = 0.0001). BDVA was above 0.8 in 31.25% (5/16) of bilateral cases. Significant stereopsis improvement was observed postoperatively in bilateral cases only (p = 0.01). Conclusion: MIOL implantation is a safe alternative to monofocal pseudophakia for pediatric cataract with a very low complication rate. Significant BNVA, BDVA and stereopsis improvement can be achieved, particularly in bilateral cases. Message: This study shows significant BDVA, BNVA and stereopsis improvement, especially in bilateral cases, after MIOL implantation for pediatric cataracts. © 2013 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.