239 resultados para internal reconstruction

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the standard tools used to understand the processes shaping trait evolution along the branches of a phylogenetic tree is the reconstruction of ancestral states (Pagel 1999). The purpose is to estimate the values of the trait of interest for every internal node of a phylogenetic tree based on the trait values of the extant species, a topology and, depending on the method used, branch lengths and a model of trait evolution (Ronquist 2004). This approach has been used in a variety of contexts such as biogeography (e.g., Nepokroeff et al. 2003, Blackburn 2008), ecological niche evolution (e.g., Smith and Beaulieu 2009, Evans et al. 2009) and metabolic pathway evolution (e.g., Gabaldón 2003, Christin et al. 2008). Investigations of the factors affecting the accuracy with which ancestral character states can be reconstructed have focused in particular on the choice of statistical framework (Ekman et al. 2008) and the selection of the best model of evolution (Cunningham et al. 1998, Mooers et al. 1999). However, other potential biases affecting these methods, such as the effect of tree shape (Mooers 2004), taxon sampling (Salisbury and Kim 2001) as well as reconstructing traits involved in species diversification (Goldberg and Igić 2008), have also received specific attention. Most of these studies conclude that ancestral character states reconstruction is still not perfect, and that further developments are necessary to improve its accuracy (e.g., Christin et al. 2010). Here, we examine how different estimations of branch lengths affect the accuracy of ancestral character state reconstruction. In particular, we tested the effect of using time-calibrated versus molecular branch lengths and provide guidelines to select the most appropriate branch lengths to reconstruct the ancestral state of a trait.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: When planning SIRT using 90Y microspheres, the partition model is used to refine the activity calculated by the body surface area (BSA) method to potentially improve the safety and efficacy of treatment. For this partition model dosimetry, accurate determination of mean tumor-to-normal liver ratio (TNR) is critical since it directly impacts absorbed dose estimates. This work aimed at developing and assessing a reliable methodology for the calculation of 99mTc-MAA SPECT/CT-derived TNR ratios based on phantom studies. Materials and methods: IQ NEMA (6 hot spheres) and Kyoto liver phantoms with different hot/background activity concentration ratios were imaged on a SPECT/CT (GE Infinia Hawkeye 4). For each reconstruction with the IQ phantom, TNR quantification was assessed in terms of relative recovery coefficients (RC) and image noise was evaluated in terms of coefficient of variation (COV) in the filled background. RCs were compared using OSEM with Hann, Butterworth and Gaussian filters, as well as FBP reconstruction algorithms. Regarding OSEM, RCs were assessed by varying different parameters independently, such as the number of iterations (i) and subsets (s) and the cut-off frequency of the filter (fc). The influence of the attenuation and diffusion corrections was also investigated. Furthermore, both 2D-ROIs and 3D-VOIs contouring were compared. For this purpose, dedicated Matlab© routines were developed in-house for automatic 2D-ROI/3D-VOI determination to reduce intra-user and intra-slice variability. Best reconstruction parameters and RCs obtained with the IQ phantom were used to recover corrected TNR in case of the Kyoto phantom for arbitrary hot-lesion size. In addition, we computed TNR volume histograms to better assess uptake heterogeneityResults: The highest RCs were obtained with OSEM (i=2, s=10) coupled with the Butterworth filter (fc=0.8). Indeed, we observed a global 20% RC improvement over other OSEM settings and a 50% increase as compared to the best FBP reconstruction. In any case, both attenuation and diffusion corrections must be applied, thus improving RC while preserving good image noise (COV<10%). Both 2D-ROI and 3D-VOI analysis lead to similar results. Nevertheless, we recommend using 3D-VOI since tumor uptake regions are intrinsically 3D. RC-corrected TNR values lie within 17% around the true value, substantially improving the evaluation of small volume (<15 mL) regions. Conclusions: This study reports the multi-parameter optimization of 99mTc MAA SPECT/CT images reconstruction in planning 90Y dosimetry for SIRT. In phantoms, accurate quantification of TNR was obtained using OSEM coupled with Butterworth and RC correction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: An operative technique is described as a salvage treatment for severe subglottic and supraglottic laryngeal stenosis. In addition to expansion of the laryngeal framework with an anterior cartilage graft, as used in a classical laryngotracheal reconstruction, the scar tissue obliterating the airway lumen is excised and a mucosal graft is placed to reconstruct the inner lining of the airway. The graft is harvested from buccal mucosa. METHODS: The operative technique is outlined. Three cases, 2 paediatric and one adult, with complete or near complete laryngeal stenosis are presented where this operative technique was employed. In all patients several surgeries had been performed previously which were unsuccessful. RESULTS: In all 3 patients a patent airway was achieved with decannulation of the tracheostomy in the 2 paediatric patients. CONCLUSIONS: In patients with severe subglottic or supraglottic airway stenosis where other surgeries have failed, excision of endoluminal scar tissue and placement of a buccal mucosal graft, in addition to conventional laryngotracheal reconstruction, is a promising technique. In revision cases of subglottic stenosis cricotracheal resection might not be an option because of scarring from previous surgeries. This operation is an alternative, which allows an increase in the airway lumen by excising the scar tissue then re-lining the exposed internal lumen. The buccal mucosa reduces granulation formation and re-stenosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: Patients with anterior cruciate ligament (ACL) reconstruction and femoral catheter analgesia may develop quadriceps amyotrophy. We aimed to determine whether this amyotrophy might be related to a femoral neuropathy. Material and method: After Ethical Committee approval and patients' written informed consent, 17 patients ASA I and II scheduled to undergo ACL reconstruction were recruited. An electromyography (EMG) was performed before the operation in order to exclude a femoral neuropathy. A femoral nerve catheter was inserted before the surgery with the aid of a nerve stimulator, and 20 ml of 0.5% ropivacaine was injected. The operation was done under spinal or general anaesthesia. Postoperative analgesia was provided with 0.2% ropivacaine for 72 hours, in association with oxycodone, paracetamol and ibuprofen. A second EMG was performed 4 weeks after the ACL repair. A femoral neuropathy was defined as a reduction of the surface of the motor response of more than 20%, compared to the first EMG. A third EMG was performed at 6 months if a neuropathy was present. Results: Mean age of this group of patients was 27 years old (range 18-38 y.). Among the 17 patients, 4 developed a transient femoral neuropathy (incidence of 24%) without clinical complain. Conclusion: In this study, the incidence of subclinical femoral neuropathy after ACL reconstruction is high. This lesion may be caused by the femoral catheter (mechanical damage, toxicity of local anaesthesia) or by the Tourniquet. Further studies are needed to investigate the incidence of subclinical neuropathy, according to the type of analgesia (epidural analgesia, PCA) and surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Renal transplantation is considered the treatment of choice for end-stage renal disease. However, the association of occlusive aorto-iliac disease and chronic renal failure is frequent and aorto-iliac reconstruction may be necessary prior to renal transplantation. This retrospective study reviews the results of this operative strategy.Material and Methods: Between January 2001 and June 2010, 309 patients underwent renal transplantation at our institution and 8 patients had prior aorto-iliac reconstruction using prosthetic material. There were 6 men and 2 women with a median age of 62 years (range 51-70). Five aorto-bifemoral and 2 aorto-bi-iliac bypasses were performed for stage II (n=5), stage IV (n=1) and aortic aneurysm (n=1). In one patient, iliac kissing stents and an ilio-femoral bypass were implanted. 4 cadaveric and 4 living donor renal transplantations were performed with an interval of 2 months to 10 years after revascularization.The results were analysed with respect of graft and patients survival. Differences between groups were tested by the log rank method.Results: No complications and no death occurred in the post-operative period. All bypasses remained patent during follow-up. The median time of post transplantation follow-up was 46 months for all patients and 27 months for patients with prior revascularization. In the revascularized group and control group, the graft and patient survival at 1 year were respectively 100%/96%, 100%/99% and at 5 years 86%/86%, 86%/94%, without significant differences between both groups.Discussion: Our results suggest that renal transplantation following prior aorto-iliac revascularisation with prosthetic material is safe and effective. Patients with end-stage renal disease and concomitant aorto-iliac disease should therefore be considered for renal transplantation. However, caution in the interpretation of the results is indicated due to the small sample size of our study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Waveform tomographic imaging of crosshole georadar data is a powerful method to investigate the shallow subsurface because of its ability to provide images of pertinent petrophysical parameters with extremely high spatial resolution. All current crosshole georadar waveform inversion strategies are based on the assumption of frequency-independent electromagnetic constitutive parameters. However, in reality, these parameters are known to be frequency-dependent and complex and thus recorded georadar data may show significant dispersive behavior. In this paper, we evaluate synthetically the reconstruction limits of a recently published crosshole georadar waveform inversion scheme in the presence of varying degrees of dielectric dispersion. Our results indicate that, when combined with a source wavelet estimation procedure that provides a means of partially accounting for the frequency-dependent effects through an "effective" wavelet, the inversion algorithm performs remarkably well in weakly to moderately dispersive environments and has the ability to provide adequate tomographic reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'objectif de cette étude est d'examiner la structure factorielle et la consistance interne de la TAS-20 sur un échantillon d'adolescents (n = 264), ainsi que de décrire la distribution des caractéristiques alexithymiques dans cet échantillon. La structure à trois facteurs de la TAS-20 a été confirmée par notre analyse factorielle confirmatoire. La consistance interne, mesurée à l'aide d'alpha de Cronbach, est acceptable pour le premier facteur (difficulté à identifier les sentiments (DIF)), bonne pour le second (difficulté à verbaliser les sentiments (DDF)), mais en revanche, faible pour le troisième facteur (pensées orientées vers l'extérieur (EOT)). Les résultats d'une Anova mettent en évidence une tendance linéaire indiquant que plus l'âge augmente plus le niveau d'alexithymie (score total TAS-20), la difficulté à identifier les sentiments et les pensées orientées vers l'extérieur diminuent. En ce qui concerne la prévalence de l'alexithymie, on remarque en effet que 38,5 % des adolescents de moins de 16 ans sont considérés comme alexithymiques, contre 30,1 % des 16-17 ans et 22 % des plus de 17 ans. Notre étude indique donc que la TAS-20 est un instrument adéquat pour évaluer l'alexithymie à l'adolescence, tout en suggérant quelques précautions étant donné l'aspect développemental de cette période.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.