6 resultados para hospital setting

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The treatment of status epilepticus (SE) is based on relatively little evidence although several guidelines have been published. A recent study reported a worse SE prognosis in a large urban setting as compared to a peripheral hospital, postulating better management in the latter. The aim of this study was to analyse SE episodes occurring in different settings and address possible explanatory variables regarding outcome, including treatment quality. METHODS: Over six months we prospectively recorded consecutive adults with SE (fit lasting five or more minutes) at the Centre Hospitalier Universitaire Vaudois (CHUV) and in six peripheral hospitals (PH) in the same region. Demographical, historical and clinical variables were collected, including SE severity estimation (STESS score) and adherence to Swiss SE treatment guidelines. Outcome at discharge was categorised as "good" (return to baseline), or "poor" (persistent neurological sequelae or death). RESULTS: Of 54 patients (CHUV: 36; PH 18), 33% had a poor outcome. Whilst age, SE severity, percentage of SE episodes lasting less than 30 minutes and total SE duration were similar, fewer patients had a good outcome at the CHUV (61% vs 83%; OR 3.57; 95% CI 0.8-22.1). Mortality was 14% at the CHUV and 5% at the PH. Most treatments were in agreement with national guidelines, although less often in PH (78% vs 97%, P = 0.04). CONCLUSION: Although not statistically significant, we observed a slightly worse SE prognosis in a large academic centre as compared to smaller hospitals. Since SE severity was similar in the two settings but adherence to national treatment guidelines was higher in the academic centre, further investigation on the prognostic role of SE treatment and outcome determinants is required.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

SETTING: A 950 bed teaching hospital in Switzerland. AIM: To describe the result of a contact investigation among health care workers (HCW) and patients after exposure to a physician with smear-positive pulmonary tuberculosis in a hospital setting using standard tuberculin skin tests (TST) and Interferon-gamma release assay (IGRA). METHOD: HCW with a negative or unknown TST at hiring had a TST two weeks after the last contact with the index case (T0), repeated six weeks later if negative (T6). All exposed HCW had a T-SPOT.TB at T0 and T6. Exposed patients had a TST six weeks after the last contact, and a T-SPOT.TB if the TST was positive. RESULTS: Among 101 HCW, 17/73 (22%) had a positive TST at T0. TST was repeated in 50 at T6 and converted from negative to positive in eight (16%). Twelve HCW had a positive T-SPOT.TB at T0 and ten converted from negative to positive at T6. Seven HCW with a positive T-SPOT.TB reverted to negative at T6 or at later controls, most of them with test values close to the cut-off. Among 27 exposed patients tested at six weeks, ten had a positive TST, five of them confirmed by a positive T-SPOT.TB. CONCLUSIONS: HCW tested twice after exposure to a case of smear-positive pulmonary TB demonstrated a possible conversion in 10% with T-SPOT and 16% with TST. Some T-SPOT.TB reverted from positive to negative during the follow-up, mostly tests with a value close to the cut-off. Due to the variability of the test results, it seems advisable to repeat the test with values close to the cut-off before diagnosing the presence of a tuberculous infection.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: Methicillin-resistant Staphylococcus aureus (MRSA) is a major cause of both hospital- and community-acquired infections worldwide. However, data about the molecular epidemiology of MRSA in North Africa are still scarce. METHODOLOGY: All MRSA isolates recovered between January 2006 and July 2011 from one Algerian hospital were genetically and phenotypically characterized. RESULTS: The predominance of a European community-associated-MRSA (CA-MRSA) clone (ST80-SCCmec IV-PVL positive) was revealed by this analysis. CONCLUSION: Our data suggest that a CA-MRSA clone recently invaded the hospital setting in Algiers and replaced a typical hospital-associated pandemic clone such as the Brazilian clone (ST239-SCCmec IIImercury-PVL negative).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Methicillin resistant Staphylococcus aureus (MRSA) bacteria have emerged in the early 1980's in numerous health care institutions around the world. The main transmission mechanism within hospitals and healthcare facilities is through the hands of health care workers. Resistant to several antibiotics, the MRSA is one of the most feared pathogens in the hospital setting since it is very difficult to eradicate with the standard treatments. There are still a limited number of anti-MRSA antibiotics but the first cases of resistance to these compounds have already been reported and their frequency is likely to increase in the coming years. Every year, the MRSA infections result in major human and financial costs, due to the high associated mortality and expenses related to the required care. Measures towards a faster detection of resistant bacteria and establishment of appropriate antibiotic treatment parameters are fundamental. Also as part as infection prevention, diminution of bacteria present on the commonly touched surfaces could also limit the spread and selection of antibiotic resistant bacteria. During my thesis, projects were developed around MRSA and antibiotic resistance investigation using innovative technologies. The thesis was subdivided in three main parts with the use of atomic force microscopy AFM for antibiotic resistance detection in part 1, the importance of the bacterial inoculum size in the selection of antibiotic resistance in part 2 and the testing of antimicrobial surfaces creating by sputtering copper onto polyester in part 3. In part 1 the AFM was used two different ways, first for the measurement of stiffness (elasticity) of bacteria and second as a nanosensor for antibiotic susceptibility testing. The stiffness of MRSA with different susceptibility profiles to vancomycin was investigated using the stiffness tomography mode of the AFM and results have demonstrated and increased stiffness in the vancomycin resistant strains that also paralleled with increased thickness of the bacterial cell wall. Parts of the AFM were also used to build a new antibiotic susceptibility-testing device. This nano sensor was able to measure vibrations emitted from living bacteria that ceased definitively upon antibiotic exposure to which they were susceptible but restarted after antibiotic removal to which they were resistant, allowing in a matter of minute the assessment of antibiotic susceptibility determination. In part 2 the inoculum effect (IE) of vancomycin, daptomycin and linezolid and its importance in antibiotic resistance selection was investigated with MRSA during a 15 days of cycling experiment. Results indicated that a high bacterial inoculum and a prolonged antibiotic exposure were two key factors in the in vitro antibiotic resistance selection in MRSA and should be taken into consideration when choosing the drug treatment. Finally in part 3 bactericidal textile surfaces were investigated against MRSA. Polyesters coated after 160 seconds of copper sputtering have demonstrated a high bactericidal activity reducing the bacterial load of at least 3 logio after one hour of contact. -- Au cours des dernières décennies, des bactéries multirésistantes aux antibiotiques (BMR) ont émergé dans les hôpitaux du monde entier. Depuis lors, le nombre de BMR et la prévalence des infections liées aux soins (IAS) continuent de croître et sont associés à une augmentation des taux de morbidité et de mortalité ainsi qu'à des coûts élevés. De plus, le nombre de résistance à différentes classes d'antibiotiques a également augmenté parmi les BMR, limitant ainsi les options thérapeutiques disponibles lorsqu'elles ont liées a des infections. Des mesures visant une détection plus rapide des bactéries résistantes ainsi que l'établissement des paramètres de traitement antibiotiques adéquats sont primordiales lors d'infections déjà présentes. Dans une optique de prévention, la diminution des bactéries présentes sur les surfaces communément touchées pourrait aussi freiner la dissémination et l'évolution des bactéries résistantes. Durant ma thèse, différents projets incluant des nouvelles technologies et évoluant autour de la résistance antibiotique ont été traités. Des nouvelles technologies telles que le microscope à force atomique (AFM) et la pulvérisation cathodique de cuivre (PCC) ont été utilisées, et le Staphylococcus aureus résistant à la méticilline (SARM) a été la principale BMR étudiée. Deux grandes lignes de recherche ont été développées; la première visant à détecter la résistance antibiotique plus rapidement avec l'AFM et la seconde visant à prévenir la dissémination des BMR avec des surfaces crées grâce à la PCC. L'AFM a tout d'abord été utilisé en tant que microscope à sonde locale afin d'investiguer la résistance à la vancomycine chez les SARMs. Les résultats ont démontré que la rigidité de la paroi augmentait avec la résistance à la vancomycine et que celle-ci corrélait aussi avec une augmentation de l'épaisseur des parois, vérifiée grâce à la microscopie électronique. Des parties d'un AFM ont été ensuite utilisées afin de créer un nouveau dispositif de test de sensibilité aux antibiotiques, un nanocapteur. Ce nanocapteur mesure des vibrations produites par les bactéries vivantes. Après l'ajout d'antibiotique, les vibrations cessent définitivement chez les bactéries sensibles à l'antibiotique. En revanche pour les bactéries résistantes, les vibrations reprennent après le retrait de l'antibiotique dans le milieu permettant ainsi, en l'espace de minutes de détecter la sensibilité de la bactérie à un antibiotique. La PCC a été utilisée afin de créer des surfaces bactéricides pour la prévention de la viabilité des BMR sur des surfaces inertes. Des polyesters finement recouverts de cuivre (Cu), connu pour ses propriétés bactéricides, ont été produits et testés contre des SARMs. Une méthode de détection de viabilité des bactéries sur ces surfaces a été mise au point, et les polyesters obtenus après 160 secondes de pulvérisation au Cu ont démontré une excellente activité bactéricide, diminuant la charge bactérienne d'au moins 3 logio après une heure de contact. En conclusion, l'utilisation de nouvelles technologies nous a permis d'évoluer vers de méthodes de détection de la résistance antibiotique plus rapides ainsi que vers le développement d'un nouveau type de surface bactéricide, dans le but d'améliorer le diagnostic et la gestion des BMR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Breakthrough technologies which now enable the sequencing of individual genomes will irreversibly modify the way diseases are diagnosed, predicted, prevented and treated. For these technologies to reach their full potential requires, upstream, access to high-quality biomedical data and samples from large number of properly informed and consenting individuals and, downstream, the possibility to transform the emerging knowledge into a clinical utility. The Lausanne Institutional Biobank was designed as an integrated, highly versatile infrastructure to harness the power of these emerging technologies and catalyse the discovery and development of innovative therapeutics and biomarkers, and advance the field of personalised medicine. Described here are its rationale, design and governance, as well as parallel initiatives which have been launched locally to address the societal, ethical and technological issues associated with this new bio-resource. Since January 2013, inpatients admitted at Lausanne CHUV University Hospital have been systematically invited to provide a general consent for the use of their biomedical data and samples for research, to complete a standardised questionnaire, to donate a 10-ml sample of blood for future DNA extraction and to be re-contacted for future clinical trials. Over the first 18 months of operation, 14,459 patients were contacted, and 11,051 accepted to participate in the study. This initial 18-month experience illustrates that a systematic hospital-based biobank is feasible; it shows a strong engagement in research from the patient population in this University Hospital setting, and the need for a broad, integrated approach for the future of medicine to reach its full potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Because of its high prevalence, early screening for occupational asthma (OA) is crucial. We aimed to evaluate the screening performance of the Occupational Asthma Screening Questionnaire-11 items (OASQ-11) in a clinical setting. METHODS: Between January 2009 and December 2011, 169 workers referred for potential OA to our hospital completed the OASQ-11 and underwent workups to determine the final diagnosis. The discriminative abilities of the OASQ-11 as a whole and in relation to demographic and exposure parameters were determined by the area under the receiving operator characteristic curve (AUC). RESULTS: Model 1, consisting of the OASQ's items, showed fair discrimination (AUC, 0.69; 95% confidence interval, 0.58 to 0.80). Addition of age and exposure duration to model 1 improved discrimination (AUC, 0.80; confidence interval, 0.72 to 0.88). CONCLUSION: A simple model consisting of the OASQ-11's items, age, and exposure duration could well discriminate subjects with OA in a clinical setting.