156 resultados para hologram recording
em Université de Lausanne, Switzerland
Resumo:
Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE
Resumo:
Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.
Resumo:
Ambulatory blood pressure (BP) was recorded in hypertensive patients whose physicians had been asked to reduce diastolic pressure measured in the office to 90 mm Hg or less. 34 hypertensive patients with a diastolic pressure measured by their physician of 95 mm Hg or more despite antihypertensive therapy had their treatment changed with the aim of achieving this pre-set goal within 3 months. At the beginning and the end of the study, ambulatory BP was monitored during the daytime with a portable non-invasive recorder. The results of the ambulatory recordings were not made available to the physicians until completion of the study. In half the patients the ambulatory diastolic pressure was already 90 mm Hg or less at the start. In these patients, treatment adjustment did not further decrease ambulatory BP. In contrast, patients who initially had an ambulatory diastolic pressure above 90 mm Hg had a significantly decreased ambulatory BP at the end of the study. Intensifying the therapy of hypertensive patients who have a normal ambulatory BP may result in overtreatment without any real gain in BP control.
Resumo:
The mammalian circadian timing system consists of a master pacemaker in the suprachiasmatic nucleus (SCN) in the hypothalamus, which is thought to set the phase of slave oscillators in virtually all body cells. However, due to the lack of appropriate in vivo recording technologies, it has been difficult to study how the SCN synchronizes oscillators in peripheral tissues. Here we describe the real-time recording of bioluminescence emitted by hepatocytes expressing circadian luciferase reporter genes in freely moving mice. The technology employs a device dubbed RT-Biolumicorder, which consists of a cylindrical cage with reflecting conical walls that channel photons toward a photomultiplier tube. The monitoring of circadian liver gene expression revealed that hepatocyte oscillators of SCN-lesioned mice synchronized more rapidly to feeding cycles than hepatocyte clocks of intact mice. Hence, the SCN uses signaling pathways that counteract those of feeding rhythms when their phase is in conflict with its own phase.
Resumo:
Chloride channels represent a group of targets for major clinical indications. However, molecular screening for chloride channel modulators has proven to be difficult and time-consuming as approaches essentially rely on the use of fluorescent dyes or invasive patch-clamp techniques which do not lend themselves to the screening of large sets of compounds. To address this problem, we have developed a non-invasive optical method, based on digital holographic microcopy (DHM), allowing monitoring of ion channel activity without using any electrode or fluorescent dye. To illustrate this approach, GABA(A) mediated chloride currents have been monitored with DHM. Practically, we show that DHM can non-invasively provide the quantitative determination of transmembrane chloride fluxes mediated by the activation of chloride channels associated with GABA(A) receptors. Indeed through an original algorithm, chloride currents elicited by application of appropriate agonists of the GABA(A) receptor can be derived from the quantitative phase signal recorded with DHM. Finally, chloride currents can be determined and pharmacologically characterized non-invasively simultaneously on a large cellular sampling by DHM.
Resumo:
INTRODUCTION The chemical senses smell and taste, detect and discriminate an enormous diversity of environmental stimuli and provide fascinating but challenging models to investigate how sensory cues are represented in the brain. Important stimulus-coding events occur in peripheral sensory neurons, which express specific combinations of chemosensory receptors with defined ligand-response profiles. These receptors convert ligand recognition into spatial and temporal patterns of neural activity that are transmitted to and interpreted in central brain regions. Drosophila provides an attractive model to study chemosensory coding, because it possesses relatively simple peripheral olfactory and gustatory systems that display many organizational parallels to those of vertebrates. Moreover, virtually all of the peripheral chemosensory neurons are easily accessible for physiological analysis, as they are exposed on the surface of sensory organs in specialized sensory hairs called sensilla. In recent years, improvements in microscopy and instrumentation for electrode manipulation have opened up the much smaller Drosophila system to electrophysiological techniques, powerfully complementing many years of molecular genetic studies. As with most electrophysiological methods, there is probably no substitute for learning this technique directly from a laboratory in which it is already established. This protocol describes the basics of setting up the electrophysiology rig and stimulus delivery device, sample preparation, and performing and analyzing recordings of stimulus-evoked activity from Drosophila taste sensilla.
Resumo:
Parameters of intrarectal pressure (surface area under pressure curve and peak pressure) recorded with a microsystem device during the second phase of labor showed no significant correlations with baby's weight or mode of delivery. AIM OF THE STUDY: Was to assess the biomechanical pressures delivered against pelvic floor structures during the second phase of labor in nulliparae women, and to correlate them with obstetrics parameters, i.e. baby'sweight and mode of delivery. MATERIAL: Using a microsystem device placed into the rectum at the beginning of the second phase of labor, two parameters were assessed during the bearing efforts in 59 nulliparae women: the surface area under the pressure curve and the peak pressure. RESULTS: During 11.5±9 bearing efforts of 99.1±16s duration, the mean value of surface area under the pressure curve was 32677±26058cm/s and the mean value of the peak pressure was 60.7±24cmH(2)O, exceeding 100cmH(2)O in 10% of women. These two parameters were not correlated with baby's weight (R: 0.19, P: 0.15 and R: 0.05, P: 0.71). In the same way, these two parameters were not correlated with the mode of delivery (spontaneous or forceps/vacuum-assisted). Furthermore, the individual values of these two parameters showed great variation from one woman to another. CONCLUSION: This study has showed that parameters of biomechanical pressures recorded into the rectum during second phase of labor had no significant correlations with obstetricals parameters, explaining why these latter have poor predicitive value of further pelvic floor problems.
Resumo:
We present a new lab-on-a-chip system for electrophysiological measurements on Xenopus oocytes. Xenopus oocytes are widely used host cells in the field of pharmacological studies and drug development. We developed a novel non-invasive technique using immobilized non-devitellinized cells that replaces the traditional "two-electrode voltage-clamp" (TEVC) method. In particular, rapid fluidic exchange was implemented on-chip to allow recording of fast kinetic events of exogenous ion channels expressed in the cell membrane. Reducing fluidic exchange times of extracellular reagent solutions is a great challenge with these large millimetre-sized cells. Fluidic switching is obtained by shifting the laminar flow interface in a perfusion channel under the cell by means of integrated poly-dimethylsiloxane (PDMS) microvalves. Reagent solution exchange times down to 20 ms have been achieved. An on-chip purging system allows to perform complex pharmacological protocols, making the system suitable for screening of ion channel ligand libraries. The performance of the integrated rapid fluidic exchange system was demonstrated by investigating the self-inhibition of human epithelial sodium channels (ENaC). Our results show that the response time of this ion channel to a specific reactant is about an order of magnitude faster than could be estimated with the traditional TEVC technique.
Resumo:
Question: When multiple observers record the same spatial units of alpine vegetation, how much variation is there in the records and what are the consequences of this variation for monitoring schemes to detect change? Location: One test summit in Switzerland (Alps) and one test summit in Scotland (Cairngorm Mountains). Method: Eight observers used the GLORIA protocols for species composition and visual cover estimates in percent on large summit sections (>100 m2) and species composition and frequency in nested quadrats (1 m2). Results: The multiple records from the same spatial unit for species composition and species cover showed considerable variation in the two countries. Estimates of pseudoturnover of composition and coefficients of variation of cover estimates for vascular plant species in 1m x 1m quadrats showed less variation than in previously published reports whereas our results in larger sections were broadly in line with previous reports. In Scotland, estimates for bryophytes and lichens were more variable than for vascular plants. Conclusions: Statistical power calculations indicated that, unless large numbers of plots were used, changes in cover or frequency were only likely to be detected for abundant species (exceeding 10% cover) or if relative changes were large (50% or more). Lower variation could be reached with the point methods and with larger numbers of small plots. However, as summits often strongly differ from each other, supplementary summits cannot be considered as a way of increasing statistical power without introducing a supplementary component of variance into the analysis and hence the power calculations.
Resumo:
Nonverbal behavior coding is typically conducted by "hand". To remedy this time and resource intensive undertaking, we illustrate how nonverbal social sensing, defined as the automated recording and extracting of nonverbal behavior via ubiquitous social sensing platforms, can be achieved. More precisely, we show how and what kind of nonverbal cues can be extracted and to what extent automated extracted nonverbal cues can be validly obtained with an illustrative research example. In a job interview, the applicant's vocal and visual nonverbal immediacy behavior was automatically sensed and extracted. Results show that the applicant's nonverbal behavior can be validly extracted. Moreover, both visual and vocal applicant nonverbal behavior predict recruiter hiring decision, which is in line with previous findings on manually coded applicant nonverbal behavior. Finally, applicant average turn duration, tempo variation, and gazing best predict recruiter hiring decision. Results and implications of such a nonverbal social sensing for future research are discussed.
Resumo:
Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connecting different devices in many situations; however, this is often impractical, and sometimes impossible in outdoors situations. The aim of this paper is to describe a wireless system for outdoor use, allowing synchronization of different types of - potentially embedded and moving - devices. In this system, each synchronization device is composed of: (i) a GPS receiver (used as time reference), (ii) a radio transmitter, and (iii) a microcontroller. These components are used to provide synchronized trigger signals at the desired frequency to the measurement device connected. The synchronization devices communicate wirelessly, are very lightweight, battery-operated and thus very easy to set up. They are adaptable to every measurement device equipped with either trigger input or recording channel. The accuracy of the system was validated using an oscilloscope. The mean synchronization error was found to be 0.39 μs and pulses are generated with an accuracy of <2 μs. The system provides synchronization accuracy about two orders of magnitude better than commonly used post-processing methods, and does not suffer from any drift in trigger generation.
Resumo:
For many drugs, finding the balance between efficacy and toxicity requires monitoring their concentrations in the patient's blood. Quantifying drug levels at the bedside or at home would have advantages in terms of therapeutic outcome and convenience, but current techniques require the setting of a diagnostic laboratory. We have developed semisynthetic bioluminescent sensors that permit precise measurements of drug concentrations in patient samples by spotting minimal volumes on paper and recording the signal using a simple point-and-shoot camera. Our sensors have a modular design consisting of a protein-based and a synthetic part and can be engineered to selectively recognize a wide range of drugs, including immunosuppressants, antiepileptics, anticancer agents and antiarrhythmics. This low-cost point-of-care method could make therapies safer, increase the convenience of doctors and patients and make therapeutic drug monitoring available in regions with poor infrastructure.