14 resultados para high pressurization device

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Osteoporosis (OP) is a systemic skeletal disease characterized by a low bone mineral density (BMD) and a micro-architectural (MA) deterioration. Clinical risk factors (CRF) are often used as a MA approximation. MA is yet evaluable in daily practice by the Trabecular Bone Score (TBS) measure. TBS is a novel grey-level texture measurement reflecting bone micro-architecture based on the use of experimental variograms of 2D projection images. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis value, partially independent of CRF and BMD. The aim of the OsteoLaus cohort is to combine in daily practice the CRF and the information given by DXA (BMD, TBS and vertebral fracture assessment (VFA)) to better identify women at high fracture risk. Method: The OsteoLaus cohort (1400 women 50 to 80 years living in Lausanne, Switzerland) started in 2010. This study is derived from the cohort COLAUS who started in Lausanne in 2003. The main goals of COLAUS is to obtain information on the epidemiology and genetic determinants of cardiovascular risk in 6700 men and women. CRF for OP, bone ultrasound of the heel, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded in OsteoLaus. Preliminary results are reported. Results: We included 631 women: mean age 67.4±6.7 y, BMI 26.1±4.6, mean lumbar spine BMD 0.943±0.168 (T-score -1.4 SD), TBS 1.271±0.103. As expected, correlation between BMD and site matched TBS is low (r2=0.16). Prevalence of VFx grade 2/3, major OP Fx and all OP Fx is 8.4%, 17.0% and 26.0% respectively. Age- and BMI-adjusted ORs (per SD decrease) are 1.8 (1.2- 2.5), 1.6 (1.2-2.1), 1.3 (1.1-1.6) for BMD for the different categories of fractures and 2.0 (1.4-3.0), 1.9 (1.4-2.5), 1.4 (1.1-1.7) for TBS respectively. Only 32 to 37% of women with OP Fx have a BMD < -2.5 SD or a TBS < 1.200. If we combine a BMD < -2.5 SD or a TBS < 1.200, 54 to 60% of women with an osteoporotic Fx are identified. Conclusion: As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS subsequent to BMD increases significantly the identification of women with prevalent OP Fx which would have been miss-classified by BMD alone. For the first time we are able to have complementary information about fracture (VFA), density (BMD), micro- and macro architecture (TBS & HAS) from a simple, low ionizing radiation and cheap device: DXA. Such complementary information is very useful for the patient in the daily practice and moreover will likely have an impact on cost effectiveness analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Osteoporosis (OP) is a systemic skeletal disease characterized by a low bone mineral density (BMD) and a micro-architectural (MA) deterioration. Clinical risk factors (CRF) are often used as a MA approximation. MA is yet evaluable in daily practice by the trabecular bone score (TBS) measure. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis values, partially independent of CRF and BMD. The aim of the OsteoLaus cohort is to combine in daily practice the CRF and the information given by DXA (BMD, TBS and vertebral fracture assessment (VFA)) to better identify women at high fracture risk. The OsteoLaus cohort (1400 women 50 to 80 years living in Lausanne, Switzerland) started in 2010. This study is derived from the cohort COLAUS who started in Lausanne in 2003. The main goal of COLAUS is to obtain information on the epidemiology and genetic determinants of cardiovascular risk in 6700 men and women. CRF for OP, bone ultrasound of the heel, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded in OsteoLaus. Preliminary results are reported. We included 631 women: mean age 67.4 ± 6.7 years, BMI 26.1 ± 4.6, mean lumbar spine BMD 0.943 ± 0.168 (T-score − 1.4 SD), and TBS 1.271 ± 0.103. As expected, correlation between BMD and site matched TBS is low (r2 = 0.16). Prevalence of VFx grade 2/3, major OP Fx and all OP Fx is 8.4%, 17.0% and 26.0% respectively. Age- and BMI-adjusted ORs (per SD decrease) are 1.8 (1.2-2.5), 1.6 (1.2-2.1), and 1.3 (1.1-1.6) for BMD for the different categories of fractures and 2.0 (1.4-3.0), 1.9 (1.4-2.5), and 1.4 (1.1-1.7) for TBS respectively. Only 32 to 37% of women with OP Fx have a BMD < − 2.5 SD or a TBS < 1.200. If we combine a BMD < − 2.5 SD or a TBS < 1.200, 54 to 60% of women with an osteoporotic Fx are identified. As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS subsequent to BMD increases significantly the identification of women with prevalent OP Fx which would have been misclassified by BMD alone. For the first time we are able to have complementary information about fracture (VFA), density (BMD), micro- and macro architecture (TBS and HAS) from a simple, low ionizing radiation and cheap device: DXA. Such complementary information is very useful for the patient in the daily practice and moreover will likely have an impact on cost effectiveness analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use.