94 resultados para heart-rate variability

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Research regarding communication between pediatricians and parents in pediatric consultation has mainly focused on parental satisfaction, on its influence on compliance and on communication techniques used by pediatricians. However, there is paucity in research regarding parental stress levels during pediatric consultation. Therefore, the aim of our study was to measure parental heart rate variability related as a measure of stress levels during pediatric consultation. METHODS: Video recordings with simultaneous monitoring and recording of parental heart rate were obtained from 38 pediatric consultations in the ambulatory or hospital setting of the department of pediatrics (HFR, Fribourg, Switzerland). Pulse variation was measured every 5 seconds and heart rate variability (increase or decrease were analyzed) in relation to various sections of the consultation. RESULTS: Heart rate significantly decreased at the end of the consultation compared to the beginning of the consultation (p= 0.0567). In addition, heart rate significantly decreased at the beginning of clinical examination (p= 0.0476) compared to psychosocial history taking. During the discussion of laboratory findings and diagnosis, heart rate was significantly elevated compared to the discussion of the prognosis (p=0.0505). CONCLUSION: We conclude that pediatric consultation has a significant impact on parental stress levels shown by parental heart variability. In general, it can be shown that stress levels significantly decrease at the end of the consultation compared to the beginning of the consultation. In addition, stress levels decrease at the beginning of clinical examination and increase during psychosocial history taking and discussion of laboratory findings and diagnosis. Therefore, our findings highlight the importance of a thorough consultation which include a comprehensive clinical examination with special care taken regarding psychosocial issues and information given regarding the diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: On September 11, 2001, terrorists attacked the United States. By coincidence, a North Carolina highway patrol trooper was wearing an ambulatory ECG Holter monitor at this time as part of an air pollution study. METHODS: Heart rate variability parameters were analyzed: standard deviation of normal to normal beat intervals (SDNN) and percentage of interval differences >50 ms (PNN50). RESULTS: The trooper's heart rate variability changed immediately after learning about the terrorist attacks. Heart rate increased and PNN50 decreased, while SDNN increased strongly. CONCLUSIONS: These changes suggest strong emotional sympathetic stress associated with parasympathetic withdrawal in response to the news about the terrorist attack. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of a real-time adaptive trigger delay on image quality to correct for heart rate variability in 3D whole-heart coronary MR angiography (MRA). MATERIALS AND METHODS: Twelve healthy adults underwent 3D whole-heart coronary MRA with and without the use of an adaptive trigger delay. The moment of minimal coronary artery motion was visually determined on a high temporal resolution MRI. Throughout the scan performed without adaptive trigger delay, trigger delay was kept constant, whereas during the scan performed with adaptive trigger delay, trigger delay was continuously updated after each RR-interval using physiological modeling. Signal-to-noise, contrast-to-noise, vessel length, vessel sharpness, and subjective image quality were compared in a blinded manner. RESULTS: Vessel sharpness improved significantly for the middle segment of the right coronary artery (RCA) with the use of the adaptive trigger delay (52.3 +/- 7.1% versus 48.9 +/- 7.9%, P = 0.026). Subjective image quality was significantly better in the middle segments of the RCA and left anterior descending artery (LAD) when the scan was performed with adaptive trigger delay compared to constant trigger delay. CONCLUSION: Our results demonstrate that the use of an adaptive trigger delay to correct for heart rate variability improves image quality mainly in the middle segments of the RCA and LAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This longitudinal study aimed at comparing heart rate variability (HRV) in elite athletes identified either in 'fatigue' or in 'no-fatigue' state in 'real life' conditions. METHODS: 57 elite Nordic-skiers were surveyed over 4 years. R-R intervals were recorded supine (SU) and standing (ST). A fatigue state was quoted with a validated questionnaire. A multilevel linear regression model was used to analyze relationships between heart rate (HR) and HRV descriptors [total spectral power (TP), power in low (LF) and high frequency (HF) ranges expressed in ms(2) and normalized units (nu)] and the status without and with fatigue. The variables not distributed normally were transformed by taking their common logarithm (log10). RESULTS: 172 trials were identified as in a 'fatigue' and 891 as in 'no-fatigue' state. All supine HR and HRV parameters (Beta+/-SE) were significantly different (P<0.0001) between 'fatigue' and 'no-fatigue': HRSU (+6.27+/-0.61 bpm), logTPSU (-0.36+/-0.04), logLFSU (-0.27+/-0.04), logHFSU (-0.46+/-0.05), logLF/HFSU (+0.19+/-0.03), HFSU(nu) (-9.55+/-1.33). Differences were also significant (P<0.0001) in standing: HRST (+8.83+/-0.89), logTPST (-0.28+/-0.03), logLFST (-0.29+/-0.03), logHFST (-0.32+/-0.04). Also, intra-individual variance of HRV parameters was larger (P<0.05) in the 'fatigue' state (logTPSU: 0.26 vs. 0.07, logLFSU: 0.28 vs. 0.11, logHFSU: 0.32 vs. 0.08, logTPST: 0.13 vs. 0.07, logLFST: 0.16 vs. 0.07, logHFST: 0.25 vs. 0.14). CONCLUSION: HRV was significantly lower in 'fatigue' vs. 'no-fatigue' but accompanied with larger intra-individual variance of HRV parameters in 'fatigue'. The broader intra-individual variance of HRV parameters might encompass different changes from no-fatigue state, possibly reflecting different fatigue-induced alterations of HRV pattern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the effect of a change in second-hand smoke (SHS) exposure on heart rate variability (HRV) and pulse wave velocity (PWV), this study utilized a quasi-experimental setting when a smoking ban was introduced. METHODS: HRV, a quantitative marker of autonomic activity of the nervous system, and PWV, a marker of arterial stiffness, were measured in 55 non-smoking hospitality workers before and 3-12 months after a smoking ban and compared to a control group that did not experience an exposure change. SHS exposure was determined with a nicotine-specific badge and expressed as inhaled cigarette equivalents per day (CE/d). RESULTS: PWV and HRV parameters significantly changed in a dose-dependent manner in the intervention group as compared to the control group. A one CE/d decrease was associated with a 2.3 % (95 % CI 0.2-4.4; p = 0.031) higher root mean square of successive differences (RMSSD), a 5.7 % (95 % CI 0.9-10.2; p = 0.02) higher high-frequency component and a 0.72 % (95 % CI 0.40-1.05; p < 0.001) lower PWV. CONCLUSIONS: PWV and HRV significantly improved after introducing smoke-free workplaces indicating a decreased cardiovascular risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: A few studies have suggested an association between prenatal exposure to methylmercury and decreased heart rate variability (HRV) related to autonomic heart function, but no study has examined this association using baroreflex sensitivity (BRS). In this study we assessed the distribution of BRS and immediate orthostatic hypotension (IOH) in young Seychellois adults and their associations with exposure to prenatal and recent postnatal methylmercury. METHODS: Subjects in the Seychelles Child Development Study (SCDS) main cohort were evaluated at age 19 years. Non-invasive beat-to-beat blood pressure (BP) monitoring (Finapres, Ohmeda) was performed at rest and during active standing in 95 consecutive subjects. Recent postnatal mercury exposure was measured in subjects' hair at the age of 19 years and prenatal exposure in maternal hair grown during pregnancy. BRS was estimated by sequence analysis to identify spontaneous ascending and descending BP ramps. HRV was estimated by the following markers: PNN50 (relative numbers of normal-to-normal intervals which are shorter by more than 50 ms than the immediately following normal-to-normal intervals); rMSSD (root mean of the squared sum of successive interval differences); LF/HF (low frequency/high frequency component ratio); ratio of the mean expiratory/inspiratory RR intervals (EI ratio); and the ratio between the longest RR interval 30 s after active standing and the shortest RR interval at 15 s (Max30/Min15). IOH was estimated by the deepest BP fall within the first 15 s after active standing up. RESULTS: Prenatal MeHg exposures were similar in boys and girls (6.7±4.3, 6.7±3.8 ng/g) but recent postnatal mercury levels were higher in males than females (11.2±5.8 vs 7.9±4.3 ng/g, p=0.003). Markers of autonomic heart rate control were within the normal range (BRS: 24.8±7 ms/mm Hg, PNN50: 24.9±6.8%, rMSSD: 68±22, LF/HF: 0.61±0.28) in both sexes. After standing, 51.4% of subjects had a transient systolic BP drop>40 mm Hg, but only 5.3% reported dizziness or had syncope. Prenatal and recent postnatal MeHg levels, overall, were not associated with BRS, E/I ratio, PNN50, rMSSD, LF/HF ratio, Max30/Min15 ratio, and IOH. CONCLUSIONS: This study provides no support for the hypothesis that prenatal or recent postnatal MeHg exposure from fish consumption is associated with impaired autonomic heart rate control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated changes in heart rate variability (HRV) in elite Nordic-skiers to characterize different types of "fatigue" in 27 men and 30 women surveyed from 2004 to 2008. R-R intervals were recorded at rest during 8 min supine (SU) followed by 7 min standing (ST). HRV parameters analysed were powers of low (LF), high (HF) frequencies, (LF+HF) (ms(2)) and heart rate (HR, bpm). In the 1 063 HRV tests performed, 172 corresponded to a "fatigue" state and the first were considered for analysis. 4 types of "fatigue" (F) were identified: 1. F(HF(-)LF(-))SU_ST for 42 tests: decrease in LFSU (- 46%), HFSU (- 70%), LFST (- 43%), HFST (- 53%) and increase in HRSU (+ 15%), HRST (+ 14%). 2. F(LF(+) SULF(-) ST) for 8 tests: increase in LFSU (+ 190%) decrease in LFST (- 84%) and increase in HRST (+ 21%). 3. F(HF(-) SUHF(+) ST) for 6 tests: decrease in HFSU (- 72%) and increase in HFST (+ 501%). 4. F(HF(+) SU) for only 1 test with an increase in HFSU (+ 2161%) and decrease in HRSU (- 15%). Supine and standing HRV patterns were independently modified by "fatigue". 4 "fatigue"-shifted HRV patterns were statistically sorted according to differently paired changes in the 2 postures. This characterization might be useful for further understanding autonomic rearrangements in different "fatigue" conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The most important adverse effect of BoNT-A is the systemic diffusion of the toxin. There is some evidence that the administration of high doses can increase the risk of systemic diffusion and the development of clinically evident adverse effects, however an international consensus does not exist about its maximum dose. AIM: The aim of this study was to evaluate changes in autonomic heart drive induced by high doses (higher than 600 units) of incobotulinumtoxinA injection in spastic stroke patients. Moreover, the treatment safety by monitoring adverse events occurrence was assessed. DESIGN: Case control study. POPULATION: Eleven stroke survivors with spastic hemiplegia. METHODS: Patients were treated with intramuscular focal injections of IncobotulinumtoxinA (NT 201; Xeomin®, Merz Pharmaceuticals GmbH, Frankfurt, Germany). Doses were below 12 units/Kg. Each patient underwent an ECG recording before injection and 10 days after treatment. Linear and non-linear Heart Rate variability (HRV) measures were derived from ECGs with a dedicated software. RESULTS: None of the variable considered showed statistically significant changes after BoNT-A injection. CONCLUSION: The use of incobotulinumtoxinA in adult patients at doses up to 12 units/kg seems to be safe regarding autonomic heart drive. CLINICAL REHABILITATION IMPACT: The use of IncobotulinumtoxinA up to 600 units could be a safe therapeutic option in spastic hemiplegic stroke survivors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We previously established that exogenous adenosine (ADO) induces transient arrhythmias in the developing heart via the adenosine A1 receptor (A1AR) and downstream activation of NADPH oxidase/ERK and PLC/PKC pathways. Here, we investigated the mechanisms by which accumulation of endogenous ADO and its derived compound inosine (INO) in the interstitial compartment induce rhythm and conduction troubles. The validated model of the spontaneously beating heart obtained from 4-day-old chick embryos was used. Quantitative RT-PCR showed that enzymes involved in ADO and INO metabolism (CD39, CD73 and eADA) as well as equilibrative (ENT1, -3, -4) and concentrative (CNT3) nucleoside transporters were differentially expressed in atria, ventricle and outflow tract. Inactivation of ENTs by dipyridamole, 1) increased myocardial ADO level, 2) provoked atrial arrhythmias and atrio-ventricular blocks (AVB) in 70% of the hearts, 3) prolonged P wave and QT interval without altering contractility, and 4) increased ERK2 phosphorylation. Blockade of CD73-mediated phosphohydrolysis of AMP to ADO, MEK/ERK pathway inhibition or A1AR inhibition prevented these arrhythmias. Exposure to exogenous INO also caused atrial ectopy associated with AVB and ERK2 phosphorylation which were prevented by A1AR or A2AAR antagonists exclusively or by MEK/ERK inhibitor. Inhibition of ADA-mediated conversion of ADO to INO increased myocardial ADO and decreased INO as expected, but slightly augmented heart rate variability without provoking AVB. Thus, during cardiogenesis, disturbances of nucleosides metabolism and transport, can lead to interstitial accumulation of ADO and INO and provoke arrhythmias in an autocrine/paracrine manner through A1AR and A2AAR stimulation and ERK2 activation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The magnitude of coffee-induced thermogenesis and the influence of coffee ingestion on substrate oxidation were investigated in 10 lean and 10 obese women, over two 24-h periods in a respiratory chamber. On one occasion the subjects consumed caffeinated coffee and on the other occasion, decaffeinated coffee. The magnitude of thermogenesis was smaller in obese (4.9 +/- 2.0%) than in lean subjects (7.6 +/- 1.3%). The thermogeneic response to caffeine was prolonged during the night in lean women only. The coffee-induced stimulation of energy expenditure was mediated by a concomitant increase in lipid and carbohydrate oxidation. During the next day, in postabsorptive basal conditions, the thermogenic effect of coffee had vanished, but a significant increase in lipid oxidation was observed in both groups. The magnitude of this effect was, however, blunted in obese women (lipid oxidation increased by 29 and 10% in lean and obese women, respectively). Caffeine increased urinary epinephrine excretion. Whereas urinary caffeine excretion was similar in both groups, obese women excreted more theobromine, theophylline, and paraxanthine than lean women. Despite the high levels of urinary methylxanthine excretion, thermogenesis and lipid oxidation were less stimulated in obese than in lean subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We tested the hypothesis that elevation in heart rate (HR) during submaximal exercise in the heat is related, in part, to increased percentage of maximal O(2) uptake (%Vo(2 max)) utilized due to reduced maximal O(2) uptake (Vo(2 max)) measured after exercise under the same thermal conditions. Peak O(2) uptake (Vo(2 peak)), O(2) uptake, and HR during submaximal exercise were measured in 22 male and female runners under four environmental conditions designed to manipulate HR during submaximal exercise and Vo(2 peak). The conditions involved walking for 20 min at approximately 33% of control Vo(2 max) in 25, 35, 40, and 45 degrees C followed immediately by measurement of Vo(2 peak) in the same thermal environment. Vo(2 peak) decreased progressively (3.77 +/- 0.19, 3.61 +/- 0.18, 3.44 +/- 0.17, and 3.13 +/- 0.16 l/min) and HR at the end of the submaximal exercise increased progressively (107 +/- 2, 112 +/- 2, 120 +/- 2, and 137 +/- 2 beats/min) with increasing ambient temperature (T(a)). HR and %Vo(2 peak) increased in an identical fashion with increasing T(a). We conclude that elevation in HR during submaximal exercise in the heat is related, in part, to the increase in %Vo(2 peak) utilized, which is caused by reduced Vo(2 peak) measured during exercise in the heat. At high T(a), the dissociation of HR from %Vo(2 peak) measured after sustained submaximal exercise is less than if Vo(2 max) is assumed to be unchanged during exercise in the heat.