6 resultados para hands on
em Université de Lausanne, Switzerland
Resumo:
Different visual stimuli have been shown to recruit different mental imagery strategies. However the role of specific visual stimuli properties related to body context and posture in mental imagery is still under debate. Aiming to dissociate the behavioural correlates of mental processing of visual stimuli characterized by different body context, in the present study we investigated whether the mental rotation of stimuli showing either hands as attached to a body (hands-on-body) or not (hands-only), would be based on different mechanisms. We further examined the effects of postural changes on the mental rotation of both stimuli. Thirty healthy volunteers verbally judged the laterality of rotated hands-only and hands-on-body stimuli presented from the dorsum- or the palm-view, while positioning their hands on their knees (front postural condition) or behind their back (back postural condition). Mental rotation of hands-only, but not of hands-on-body, was modulated by the stimulus view and orientation. Additionally, only the hands-only stimuli were mentally rotated at different speeds according to the postural conditions. This indicates that different stimulus-related mechanisms are recruited in mental rotation by changing the bodily context in which a particular body part is presented. The present data suggest that, with respect to hands-only, mental rotation of hands-on-body is less dependent on biomechanical constraints and proprioceptive input. We interpret our results as evidence for preferential processing of visual- rather than kinesthetic-based mechanisms during mental transformation of hands-on-body and hands-only, respectively.
Resumo:
OBJECTIVE: The objective of this trial was to assess which type of warm-up has the highest effect on virtual reality (VR) laparoscopy performance. The following warm-up strategies were applied: a hands-on exercise (group 1), a cognitive exercise (group 2), and no warm-up (control, group 3). DESIGN: This is a 3-arm randomized controlled trial. SETTING: The trial was conducted at the department of surgery of the University Hospital Basel in Switzerland. PARTICIPANTS: A total of 94 participants, all laypersons without any surgical or VR experience, completed the study. RESULTS: A total of 96 participants were randomized, 31 to group 1, 31 to group 2, and 32 to group 3. There were 2 postrandomization exclusions. In the multivariate analysis, we found no evidence that the intervention had an effect on VR performance as represented by 6 calculated subscores of accuracy, time, and path length for (1) camera manipulation and (2) hand-eye coordination combined with 2-handed maneuvers (p = 0.795). Neither the comparison of the average of the intervention groups (groups 1 and 2) vs control (group 3) nor the pairwise comparisons revealed any significant differences in VR performance, neither multivariate nor univariate. VR performance improved with increasing performance score in the cognitive exercise warm-up (iPad 3D puzzle) for accuracy, time, and path length in the camera navigation task. CONCLUSIONS: We were unable to show an effect of the 2 tested warm-up strategies on VR performance in laypersons. We are currently designing a follow-up study including surgeons rather than laypersons with a longer warm-up exercise, which is more closely related to the final task.
Resumo:
Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.
Resumo:
In arson cases, the collection and detection of traces of ignitable liquids on a suspect's hands can provide information to a forensic investigation. Police forces currently lack a simple, robust, efficient and reliable solution to perform this type of swabbing. In this article, we describe a study undertaken to develop a procedure for the collection of ignitable liquid residues on the hands of arson suspects. Sixteen different collection supports were considered and their applicability for the collection of gasoline traces present on hands and their subsequent analysis in a laboratory was evaluated. Background contamination, consisting of volatiles emanating from the collection supports, and collection efficiencies of the different sampling materials were assessed by passive headspace extraction with an activated charcoal strip (DFLEX device) followed by gas chromatography-mass spectrometry (GC-MS) analysis. After statistical treatment of the results, non-powdered latex gloves were retained as the most suitable method of sampling. On the basis of the obtained results, a prototype sampling kit was designed and tested. This kit is made of a three compartment multilayer bag enclosed in a sealed metal can and containing three pairs of non-powdered latex gloves: one to be worn by the sampler, one consisting of a blank sample and the last one to be worn by the person suspected to have been in contact with ignitable liquids. The design of the kit was developed to be efficient in preventing external and cross-contaminations.
Resumo:
To what extent do Voting Advice Applications (VAA) have an influence on voting behaviour and to what extent should providers be hold accountable for such tools? This paper puts forward some empirical evidence from the Swiss VAA smartvote. The enormous popularity of smartvote in the last national elections in 2007 and the feedback of users and candidates let us come to the conclusion that smartvote is more than a toy and likely to have an influence on the voting decisions. Since Swiss citizens not only vote for parties but also for candidates, and the voting recommendation of smartvote is based on the political positions of the candidates, smartvote turns out to be particularly helpful. Political scientists must not keep their hands off such tools. Scientific research is needed to understand their functioning and possibilities to manipulate elections. On the bases of a legal study we come to the conclusion, that a science driven way of setting up such tools is essential for their legitimacy. However, we do not believe that there is a single best way of setting up such a tool and rather support a market like solution with different competing tools, provided they meet minimal standards like transparency and equal access for all parties and candidates. Once the process of selecting candidates and parties are directly linked to the act of voting, all these questions will become even more salient.
Resumo:
INTRODUCTION: Quantitative sensory testing (QST) is widely used in human research to investigate the integrity of the sensory function in patients with pain of neuropathic origin, or other causes such as low back pain. Reliability of QST has been evaluated on both sides of the face, hands and feet as well as on the trunk (Th3-L3). In order to apply these tests on other body-parts such as the lower lumbar spine, it is important first to establish reliability on healthy individuals. The aim of this study was to investigate intra-rater reliability of thermal QST in healthy adults, on two sites within the L5 dermatome of the lumbar spine and lower extremity. METHODS: Test-retest reliability of thermal QST was determined at the L5-level of the lumbar spine and in the same dermatome on the lower extremity in 30 healthy persons under 40 years of age. Results were analyzed using descriptive statistics and intraclass correlation coefficient (ICC). Values were compared to normative data, using Z-transformation. RESULTS: Mean intraindividual differences were small for cold and warm detection thresholds but larger for pain thresholds. ICC values showed excellent reliability for warm detection and heat pain threshold, good-to-excellent reliability for cold pain threshold and fair-to-excellent reliability for cold detection threshold. ICC had large ranges of confidence interval (95%). CONCLUSION: In healthy adults, thermal QST on the lumbar spine and lower extremity demonstrated fair-to-excellent test-retest reliability.