62 resultados para gridding accuracy
em Université de Lausanne, Switzerland
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
OBJECTIVE:: To examine the accuracy of brain multimodal monitoring-consisting of intracranial pressure, brain tissue PO2, and cerebral microdialysis-in detecting cerebral hypoperfusion in patients with severe traumatic brain injury. DESIGN:: Prospective single-center study. PATIENTS:: Patients with severe traumatic brain injury. SETTING:: Medico-surgical ICU, university hospital. INTERVENTION:: Intracranial pressure, brain tissue PO2, and cerebral microdialysis monitoring (right frontal lobe, apparently normal tissue) combined with cerebral blood flow measurements using perfusion CT. MEASUREMENTS AND MAIN RESULTS:: Cerebral blood flow was measured using perfusion CT in tissue area around intracranial monitoring (regional cerebral blood flow) and in bilateral supra-ventricular brain areas (global cerebral blood flow) and was matched to cerebral physiologic variables. The accuracy of intracranial monitoring to predict cerebral hypoperfusion (defined as an oligemic regional cerebral blood flow < 35 mL/100 g/min) was examined using area under the receiver-operating characteristic curves. Thirty perfusion CT scans (median, 27 hr [interquartile range, 20-45] after traumatic brain injury) were performed on 27 patients (age, 39 yr [24-54 yr]; Glasgow Coma Scale, 7 [6-8]; 24/27 [89%] with diffuse injury). Regional cerebral blood flow correlated significantly with global cerebral blood flow (Pearson r = 0.70, p < 0.01). Compared with normal regional cerebral blood flow (n = 16), low regional cerebral blood flow (n = 14) measurements had a higher proportion of samples with intracranial pressure more than 20 mm Hg (13% vs 30%), brain tissue PO2 less than 20 mm Hg (9% vs 20%), cerebral microdialysis glucose less than 1 mmol/L (22% vs 57%), and lactate/pyruvate ratio more than 40 (4% vs 14%; all p < 0.05). Compared with intracranial pressure monitoring alone (area under the receiver-operating characteristic curve, 0.74 [95% CI, 0.61-0.87]), monitoring intracranial pressure + brain tissue PO2 (area under the receiver-operating characteristic curve, 0.84 [0.74-0.93]) or intracranial pressure + brain tissue PO2+ cerebral microdialysis (area under the receiver-operating characteristic curve, 0.88 [0.79-0.96]) was significantly more accurate in predicting low regional cerebral blood flow (both p < 0.05). CONCLUSION:: Brain multimodal monitoring-including intracranial pressure, brain tissue PO2, and cerebral microdialysis-is more accurate than intracranial pressure monitoring alone in detecting cerebral hypoperfusion at the bedside in patients with severe traumatic brain injury and predominantly diffuse injury.
Resumo:
OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.
Resumo:
Introduction: As part of the MicroArray Quality Control (MAQC)-II project, this analysis examines how the choice of univariate feature-selection methods and classification algorithms may influence the performance of genomic predictors under varying degrees of prediction difficulty represented by three clinically relevant endpoints. Methods: We used gene-expression data from 230 breast cancers (grouped into training and independent validation sets), and we examined 40 predictors (five univariate feature-selection methods combined with eight different classifiers) for each of the three endpoints. Their classification performance was estimated on the training set by using two different resampling methods and compared with the accuracy observed in the independent validation set. Results: A ranking of the three classification problems was obtained, and the performance of 120 models was estimated and assessed on an independent validation set. The bootstrapping estimates were closer to the validation performance than were the cross-validation estimates. The required sample size for each endpoint was estimated, and both gene-level and pathway-level analyses were performed on the obtained models. Conclusions: We showed that genomic predictor accuracy is determined largely by an interplay between sample size and classification difficulty. Variations on univariate feature-selection methods and choice of classification algorithm have only a modest impact on predictor performance, and several statistically equally good predictors can be developed for any given classification problem.
Predictors and accuracy of abnormal CT perfusion in 1296 consecutive acute ischemic stroke patients.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
OBJECTIVE: To elucidate the diagnostic accuracy of granulocyte colony-stimulating factor (G-CSF), interleukin-8 (IL-8), and interleukin-1 receptor antagonist (IL-1ra) in identifying patients with sepsis among critically ill pediatric patients with suspected infection. DESIGN AND SETTING: Nested case-control study in a multidisciplinary neonatal and pediatric intensive care unit (PICU) PATIENTS: PICU patients during a 12-month period with suspected infection, and plasma available from the time of clinical suspicion (254 episodes, 190 patients). MEASUREMENTS AND RESULTS: Plasma levels of G-CSF, IL-8, and IL-1ra. Episodes classified on the basis of clinical and bacteriological findings into: culture-confirmed sepsis, probable sepsis, localized infection, viral infection, and no infection. Plasma levels were significantly higher in episodes of culture-confirmed sepsis than in episodes with ruled-out infection. The area under the receiver operating characteristic curve was higher for IL-8 and G-CSF than for IL-1ra. Combining IL-8 and G-CSF improved the diagnostic performance, particularly as to the detection of Gram-negative sepsis. Sensitivity was low (<50%) in detecting Staphylococcus epidermidis bacteremia or localized infections. CONCLUSIONS: In this heterogeneous population of critically ill children with suspected infection, a model combining plasma levels of IL-8 and G-CSF identified patients with sepsis. Negative results do not rule out S. epidermidis bacteremia or locally confined infectious processes. The model requires validation in an independent data-set.
Resumo:
BACKGROUND: Chest pain is a common complaint in primary care, with coronary heart disease (CHD) being the most concerning of many potential causes. Systematic reviews on the sensitivity and specificity of symptoms and signs summarize the evidence about which of them are most useful in making a diagnosis. Previous meta-analyses are dominated by studies of patients referred to specialists. Moreover, as the analysis is typically based on study-level data, the statistical analyses in these reviews are limited while meta-analyses based on individual patient data can provide additional information. Our patient-level meta-analysis has three unique aims. First, we strive to determine the diagnostic accuracy of symptoms and signs for myocardial ischemia in primary care. Second, we investigate associations between study- or patient-level characteristics and measures of diagnostic accuracy. Third, we aim to validate existing clinical prediction rules for diagnosing myocardial ischemia in primary care. This article describes the methods of our study and six prospective studies of primary care patients with chest pain. Later articles will describe the main results. METHODS/DESIGN: We will conduct a systematic review and IPD meta-analysis of studies evaluating the diagnostic accuracy of symptoms and signs for diagnosing coronary heart disease in primary care. We will perform bivariate analyses to determine the sensitivity, specificity and likelihood ratios of individual symptoms and signs and multivariate analyses to explore the diagnostic value of an optimal combination of all symptoms and signs based on all data of all studies. We will validate existing clinical prediction rules from each of the included studies by calculating measures of diagnostic accuracy separately by study. DISCUSSION: Our study will face several methodological challenges. First, the number of studies will be limited. Second, the investigators of original studies defined some outcomes and predictors differently. Third, the studies did not collect the same standard clinical data set. Fourth, missing data, varying from partly missing to fully missing, will have to be dealt with.Despite these limitations, we aim to summarize the available evidence regarding the diagnostic accuracy of symptoms and signs for diagnosing CHD in patients presenting with chest pain in primary care. REVIEW REGISTRATION: Centre for Reviews and Dissemination (University of York): CRD42011001170.
Resumo:
The purpose of this study was to determine the prognostic accuracy of perfusion computed tomography (CT), performed at the time of emergency room admission, in acute stroke patients. Accuracy was determined by comparison of perfusion CT with delayed magnetic resonance (MR) and by monitoring the evolution of each patient's clinical condition. Twenty-two acute stroke patients underwent perfusion CT covering four contiguous 10mm slices on admission, as well as delayed MR, performed after a median interval of 3 days after emergency room admission. Eight were treated with thrombolytic agents. Infarct size on the admission perfusion CT was compared with that on the delayed diffusion-weighted (DWI)-MR, chosen as the gold standard. Delayed magnetic resonance angiography and perfusion-weighted MR were used to detect recanalization. A potential recuperation ratio, defined as PRR = penumbra size/(penumbra size + infarct size) on the admission perfusion CT, was compared with the evolution in each patient's clinical condition, defined by the National Institutes of Health Stroke Scale (NIHSS). In the 8 cases with arterial recanalization, the size of the cerebral infarct on the delayed DWI-MR was larger than or equal to that of the infarct on the admission perfusion CT, but smaller than or equal to that of the ischemic lesion on the admission perfusion CT; and the observed improvement in the NIHSS correlated with the PRR (correlation coefficient = 0.833). In the 14 cases with persistent arterial occlusion, infarct size on the delayed DWI-MR correlated with ischemic lesion size on the admission perfusion CT (r = 0.958). In all 22 patients, the admission NIHSS correlated with the size of the ischemic area on the admission perfusion CT (r = 0.627). Based on these findings, we conclude that perfusion CT allows the accurate prediction of the final infarct size and the evaluation of clinical prognosis for acute stroke patients at the time of emergency evaluation. It may also provide information about the extent of the penumbra. Perfusion CT could therefore be a valuable tool in the early management of acute stroke patients.
Resumo:
Sentinel lymph node dissection (SLND) identifies melanoma patients with metastatic disease who would benefit from radical lymph node dissection (RLND). Rarely, patients with melanoma have an underlying lymphoproliferative disease, and melanoma metastases might develop as collision tumours in the sentinel lymph node (SLN). The aim of this study was to measure the incidence and examine the effect of collision tumours on the accuracy of SLND and on the validity of staging in this setting. Between 1998 and 2012, 750 consecutive SLNDs were performed in melanoma patients using the triple technique (lymphoscintigraphy, gamma probe and blue dye). The validity of SLND in collision tumours was analysed. False negativity was reflected by the disease-free survival. The literature was reviewed on collision tumours in melanoma. Collision tumours of melanoma and chronic lymphocytic leukaemia (CLL) were found in two SLN and in one RLND (0.4%). Subsequent RLNDs of SLND-positive cases were negative for melanoma. The patient with negative SLND developed relapse after 28 months with an inguinal lymph node metastasis of melanoma; RLND showed collision tumours. The literature review identified 12 cases of collision tumours. CLL was associated with increased melanoma incidence and reduced overall survival. This is, to our knowledge, the first assessment of the clinical value of SLND when collision tumours of melanoma and CLL are found. In this small series of three patients with both malignancies present in the same lymph node basin, lymphocytic infiltration of the CLL did not alter radioisotope uptake into the SLN. No false-negative result was observed. Our data suggest the validity of SLND in collision tumours, but given the rarity of the problem, further studies are necessary to confirm this reliability.
Resumo:
Background: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) and the combined Pons-midbrain score quantify the extent of early ischemic changes in the posterior circulation. We compared the prognostic accuracy of both scores if applied to CT angiography (CTA) source images (CTA-SI) of patients in the Basilar Artery International Cooperation Study (BASICS).Methods: BASICS was a prospective, observational, multi-centre, registry of consecutive patients who presented with acute symptomatic basilar artery occlusion (BAO). Functional outcome was assessed at 1 month. We applied pc-ASPECTS and the combined Pons-midbrain score to CTA-SI by 3-reader-consensus. Readers were blinded to clinical data. We performed multivariable logistic regression analysis, adjusting for thrombolysis, baseline NIHSS score and age, and used the output to derive ROC curves to compare the ability of both scores to discriminate patients with favourable (modified Rankin Scale [mRS] scores 0-3) from patients with unfavourable (mRS scores 4-6) functional outcome.Results: We reviewed CTAs of 158 patients (64% men, mean age 65 _ 15 years, median NIHSS score 25 [0-38], median GCS score 7 [3-15], median onset-to-CTA time 234 minutes [11-7380]). At 1 month, 40 (25%) patients had a favourable outcome, 49 (31%) had an unfavourable outcome (mRS score 4-5) and 69 (44%) were deceased. Both techniques of assessing CTA-SI hypoattenuation in the posterior circulation showed equally good discriminative value in predicting final outcome (C-statistics; area under ROC curve 0.74 versus 0.75, respectively; p_0.37). Pc-ASPECTS dichotomized at _6 versus _6 was an independent predictor of favourable functional outcome (RR _ 2.2; CI95 1.1-4.7; p _ 0.034).Conclusion: Compared to the combined Pons-midbrain score, the pc-ASPECTS score has similar prognostic accuracy to identify patients with a favourable functional outcome in BASICS. Dichotomized pc-ASPECTS (_6 versus _6) is an independent predictor of favourable functional outcome in this population. Author Disclosures: V. Puetz: None. A. Khomenko: None. M.D. Hill: None. I. Dzialowski: None. P. Michel: None. C. Weimar: None. C.A.C. Wijman: None. H. Mattle: None. K. Muir: None. T. Pfefferkorn: None. D. Tanne: None. S. Engelter: None. K. Szabo: None. A. Algra: None. A.M. Demchuk: None. W.J. Schonewille: None.
Resumo:
BACKGROUND: Plasma free and urinary metanephrines are recognized biomarkers for the assessment of pheochromocytoma. Plasma total metanephrines with a long half-life may represent another useful biomarker. OBJECTIVE: The aim of this study is to evaluate the diagnostic performances of plasma total metanephrines alone or combined with free metanephrines and fractionated 24-h urinary metanephrines. METHODS: A retrospective, case-control diagnostic test study was conducted between 1999 and 2007 in two university hospitals in Switzerland and two institutions in France. The patients included 46 cases with histologically proven pheochromocytoma, and 181 controls suspected of tumor with negative investigations and 3-year follow-up. None had renal dysfunction. Sensitivity and specificity were compared after expressing each measurement result as a ratio over its upper reference limit, adding the ratios of normetanephrine and metanephrine, and defining cut-off values of 1 or 2 for this sum. RESULTS: Applying a cut-off value of 1, plasma free and total metanephrines and urinary fractionated metanephrines had similar sensitivities of 96% (95% confidence interval, 86-99%), 95% (85-99%), and 95% (84-99%) along with similar specificities of 89% (83-94%), 91% (84-95%), and 86% (80-91%). A cut-off of 2 for the sum of ratios over reference limit improves the specificity, and it can be used for a confirmation test based on another biomarker taken among the three biomarkers. CONCLUSION: All three metanephrine-based tests perform equivalently for diagnosing pheochromocytoma in the absence of renal insufficiency, and can be conveniently associated two by two for confirming/excluding tumor.
Resumo:
OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.