39 resultados para generación beat
em Université de Lausanne, Switzerland
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
Mobile technologies have brought about major changes in police equipment and police work. If a utopian narrative remains strongly linked to the adoption of new technologies, often formulated as 'magic bullets' to real occupational problems, there are important tensions between their 'imagined' outcomes and the (unexpected) effects that accompany their daily 'practical' use by police officers. This article offers an analysis of police officers' perceptions and interactions with security devices. In so doing, it develops a conceptual typology of strategies for coping with new technology inspired by Le Bourhis and Lascoumes: challenging, neutralizing and diverting. To that purpose, we adopt an ethnographic approach that focuses on the discourses, practices and actions of police officers in relation to three security devices: the mobile digital terminal, the mobile phone and the body camera. Based on a case study of a North American municipal police department, the article addresses how these technological devices are perceived and experienced by police officers on the beat.
Resumo:
BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.
Resumo:
We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.
Resumo:
Cette année, six études utiles pour la pratique ont été retenues. L'indication à la mammographie entre 40 et 49 ans devrait être évaluée individuellement et en tenant compte des risques/bénéfices de cet examen. Au-delà de 65 ans, un dépistage systématique de la fibrillation auriculaire avec prise de pouls puis ECG (si pouls irrégulier) pourrait être réalisé de manière systématique. Les risques de complications postcolonoscopie existent, particulièrement suite à des biopsies/polypectomies, et ce risque devrait être discuté. Les inhibiteurs de la pompe à protons au long court sont un facteur de risque de fracture de hanche. S'il est important de prendre en charge des pressions artérielles élevées au-delà de 80 ans, il faut être prudent (orthostatisme). Une corticothérapie précoce suite à une paralysie faciale périphérique est efficace. This year we have selected six studies useful for the day to day practice. A mammography in women 40 to 49 years of age should be evaluated taking into account the patient's profile and the possible risks and benefits of this exam. In patients over 65 years of age, a systematic atrial fibrillation screening, with pulse rate measuring then ECG (if irregular beat) should be realised on a regular basis. The risks for complications following colonoscopies do exist, especially after biopsies/polypectomies and this risk should be discussed. Long term proton pump inhibitor treatment is a risk factor for hip fracture. It is important to treat high blood pressure problems in the elderly, but the orthostatic risks should be adressed. A corticoid treatment started quickly for Bell's palsy is efficient
Resumo:
Recently, we were faced with a request from a student photographer who wanted to take pictures of bodies donated to our institute and used for dissection courses for medical students or for scientific purposes. Students are expressly forbidden to take pictures in the dissection hall; however, we allowed this student photographer to do her diploma work in our institute. The reason why she was proposing such a topic was that her brother died young and her parents donated his body to science. To overcome this loss of a loved one, she wanted to know what happens to the donated bodies. She followed the procedure of embalming and different dissections that took place during the summer semester and she took pictures throughout. The outcome of this work was a very nice photographic document, called 'dissection', a book with many pictures but no figure legends. The image document shows the different steps in the preparation and preservation of bodies and the work of an anatomist in the dissection hall. As we impose rules on our students, we had also to give directives in the use of the photographs taken, especially for a photographer who will use the most prominent pictures for exhibitions, i.e. that the pictures do not show names or are used for publication on the internet, or show identification numbers of cadavers, or give indication ofn the institution and are relatively anonymous. This story tells how one can deal with death and at the same time advance one's personal career. The author represents the Swiss Anatomical Society SGAHE and is supported by the Swiss Academy of Science, ScNat.
Resumo:
Oxidative metabolism of the isolated embryonic heart of the chick has been determined using a spectrophotometric technique allowing global as well as localized micromeasurements of the O2 uptake. Entire hearts, excised from embryos of 10 somites (primordia fused, stage 10 HH) and 40 somites (S shaped, stage 20 HH) were placed in a special chamber under controlled metabolic conditions where they continued to beat spontaneously and regularly. During the 32 h of development, the O2 consumption of the whole heart increased from 0.9 +/- 0.1 to 5.3 +/- 0.8 nmol O2/h. These values corrected for protein content were, however, comparable (0.45 nmol O2.h-1.micrograms-1). At stage 10-12, the O2 uptake varied along the cardiac tube (from 0.74 to 1.0 nmol O2.h-1.mm-2). From stage 10 to 20, the O2 uptake per unit area of ventricle wall increased from 0.7 +/- 0.2 to 1.8 +/- 0.2 nmol O2.h-1.mm-2, and the O2 uptake per myocardial volume during one cardiac cycle varied from 7 to 2.5 nmol O2/cm3. These results indicate that, despite an intense morphogenesis, the cardiac tissue has a rather low and stable oxidative metabolism, although the O2 requirement of the whole heart increases significantly. Moreover, the normalized suprabasal aerobic energy expenditure decreases throughout early cardiogenesis. The functional integrity of the isolated embryonic heart combined with the experimental possibilities of the microtechnique make the preparation appropriate for studying the changes in cardiac metabolism during development.
Resumo:
Ce travail décrit une étude, qui a visé à évaluer la performance d'un questionnaire de satisfaction en développement, destiné à mesurer l'opinion de patients infectés par le VIH suivis ambulatoirement. 1. Problématique. 1.1. La qualité des soins, une définition. 1.2. L'opinion des patients : comment la mesurer ? Le questionnaire, les questionnaires existants, le focus groups, description de la technique. 2. Patients et méthodes. 2.1. Critères d'inclusion et d'exclusion. 2.2. Les envois et les rappels. 2.3. Stabilité test-retest. 2.4. Le recrutement. 3. Résultats. 3.1. Acceptabilité du questionnaire : participation. 3.2. Représentativité de l'échantillon. 3.3. Scores par dimension. 3. 4. Evaluation de la validité du questionnaire, convergence des items par dimension et cohérence interne. 3.5. Les questions issues du questionnaire SF-36. 4. Discussion. 4.1. Coping et méthodes alternatives. 4.2. Impact sur les service d'une enquête sur la qualité des soins. 5.1. Le questionnaire de satisfaction élaboré. 5.2. Les différents questionnaires des Hospices : patients hospitalisés et ambulatoires. 5.3. Formulaire d'information de l'enquête par questionnaire. 5.4. Formulaire de consentement à l'enquête. 5.5. Lettre d'accompagnement du questionnaire. 5.6. Profil socio-démographique et résultats complets par item.
Resumo:
Validated in vitro methods for skin corrosion and irritation were adopted by the OECD and by the European Union during the last decade. In the EU, Switzerland and countries adopting the EU legislation, these assays may allow the full replacement of animal testing for identifying and classifying compounds as skin corrosives, skin irritants, and non irritants. In order to develop harmonised recommendations on the use of in vitro data for regulatory assessment purposes within the European framework, a workshop was organized by the Swiss Federal Office of Public Health together with ECVAM and the BfR. It comprised stakeholders from various European countries involved in the process from in vitro testing to the regulatory assessment of in vitro data. Discussions addressed the following questions: (1) the information requirements considered useful for regulatory assessment; (2) the applicability of in vitro skin corrosion data to assign the corrosive subcategories as implemented by the EU Classification, Labelling and Packaging Regulation; (3) the applicability of testing strategies for determining skin corrosion and irritation hazards; and (4) the applicability of the adopted in vitro assays to test mixtures, preparations and dilutions. Overall, a number of agreements and recommendations were achieved in order to clarify and facilitate the assessment and use of in vitro data from regulatory accepted methods, and ultimately help regulators and scientists facing with the new in vitro approaches to evaluate skin irritation and corrosion hazards and risks without animal data.
Resumo:
The present study investigates developmental changes in selective inhibition of symmetric movements with a lateralized switching task from bimanual to unimanual tapping in typically developing (TD) children and with Developmental Coordination Disorder (DCD) from 7 to 10 years old. Twelve right-handed TD children and twelve gender-matched children with DCD and probable DCD produce a motor switching task in which they have (1) to synchronize with the beat of an auditory metronome to produce bimanual symmetrical tapping and (2) to selectively inhibit their left finger's tapping while continuing their right finger's tapping and conversely. We assess (1) the development of the capacity to inhibit the stopping finger (number of supplementary taps after the stopping instruction) and (2) the development of the capacity to maintain the continuing finger (changes in the mean tempo and its variability for the continuing finger's tapping) and (3) the evolution of performance through trials. Results indicate that (1) TD children present an age-related increase in the capacity to inhibit and to maintain the left finger's tapping, (2) DCD exhibits persistent difficulties to inhibit the left finger's tapping, and (3) both groups improve their capacity to inhibit the left finger's movements through trials. In conclusion, the lateralized switching task provides a simple and fine tool to reveal differences in selective inhibition of symmetric movements in TD children and children with DCD. More theoretically, the specific improvement in selective inhibition of the left finger suggests a progressive development of inter-hemispheric communication during typical development that is absent or delayed in children with DCD.
Resumo:
The case of a 38-year old man with recurrent adenocarcinoma of the right lung and infiltration of the thoracic wall, who underwent a right pneumonectomy with thoracic wall resection, is described. Dissection of the right pulmonary hilous was extremely difficult due to the previous operations. The superior vena cava (SVC) was accidentally ligated, resulting in profound hypotension and increased venous pressure in the internal jugular vein. Immediate blood aspiration through a 8.5-French introducer sheath lowered the venous congestion. After the SVC was cross-clamped, the Bispectral Index (BIS) acutely decreased to 0 and remained low during the resuscitation. Over the next 5 hours, BIS was directly affected by mean arterial pressure. Four days postoperatively, the patient was neurologically intact.
Resumo:
BACKGROUND: On September 11, 2001, terrorists attacked the United States. By coincidence, a North Carolina highway patrol trooper was wearing an ambulatory ECG Holter monitor at this time as part of an air pollution study. METHODS: Heart rate variability parameters were analyzed: standard deviation of normal to normal beat intervals (SDNN) and percentage of interval differences >50 ms (PNN50). RESULTS: The trooper's heart rate variability changed immediately after learning about the terrorist attacks. Heart rate increased and PNN50 decreased, while SDNN increased strongly. CONCLUSIONS: These changes suggest strong emotional sympathetic stress associated with parasympathetic withdrawal in response to the news about the terrorist attack. [Authors]