111 resultados para foreign material exclusion
em Université de Lausanne, Switzerland
Resumo:
A mycotic pseudoaneurysm of the popliteal artery is usually a consequence of septic embolization and often a result of bacterial endocarditis. Conventional treatment is surgical and avoids the placement of foreign material in infected sites. Here we report our treatment of a 59-year-old man who presented with a rupture of a mycotic pseudoaneurysm of the popliteal artery due to septic embolism from sternoclavicular infectious arthritis. Radiological investigations are included. This is the first documented case of septic arthritis complicated by a rupture of a mycotic popliteal false aneurysm and treated using an endovascular procedure. Combining endovascular stent grafts with evacuation of the joint abscess and antibiotic therapy can offer a safe alternative for frail and unstable patients.
Resumo:
A bioresorbable membrane made of sodium hyaluronate and carboxymethycellulose, has been reported to prevent peritoneal adhesion. This study was designed to test its efficiency in the prevention of pericardial adhesions. Two groups of six pigs (mean weight 72 +/- 8 kg) were chosen for the experiment. The heart was exposed through a left thoracotomy and a wide patch of pericardium was excised. In the test group (n = 6), the left ventricular area without pericardium was divided into two areas: area A where six stitches of Prolene were performed, and area B which was left intact. The membrane was applied on the both areas as well as on the adjacent area covered with pericardium (area C). In the control group (n = 6), the same protocol was performed except for the membrane application. The animals were sacrificed one month later. The adhesion status as well as the visibility of the coronary anatomy was assessed according to severity scores ranging from 0 to 3 for the adhesions and from 0 to 2 for the visibility. The difference between groups was considered significant when p < 0.05. The adhesion score of the area A was 1.7 +/- 0.5 in the test group versus 2.5 +/- 0.5 in the control group (p = 0.02) and the visibility score was 1.3 +/- 0.8 and 2 +/- 0 respectively (p = 0.07). In the area B, the adhesion score was 1 +/- 0 in the test group versus 2 +/- 0.6 in the control group (p = 0.03) and the visibility score was 0.7 +/- 0.5 and 2 +/- 0 respectively (p = 0.001). Lastly, in the area C, the adhesion score was 1 +/- 0 in both groups (n.s.) and the visibility score was 0.7 +/- 0.4 in the test group versus 0.5 +/- 0.5 in the control group (n.s.). In this animal model, the role of the bioresorbable membrane in the prevention of pericardial adhesions is limited to the areas without pericardial cover and without foreign material. The presence of foreign material neutralizes its effect.
Resumo:
BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.
Resumo:
Context: Foreign body aspiration (FbA) is a serious problem in children. Accurate clinical and radiographic diagnosis is important because missed or delayed diagnosis can result in respiratory difficulties ranging from life-treatening airway obstruction to chronic wheezing or recurrent pneumonia. Bronchoscopy also has risks and accurate clinical and radiographc diagnosis can support the decision of bronchoscopy. Objective: To rewiev the diagnostic accuracy of clinical presentation (CP) and pulmonary radiograph (PR) for the diagnosis of FbA. There is no previous rewievMethods: A search of Medline is conducted for articles containing data regarding CP and PR signes of FbA. Calculation of likelihood ratios (LR) and pre and post test probability using Bayes theorem were performed for all signs of CP and PR. Inclusion criteria: Articles containing prospective data regarding CP and PR of FbA. Exclusion criteria: Retrospectives studies. Articles containing incomplete data for calculation of LR. Results: Five prospectives studies are included with a total of 585 patients. Prevalence of FbA is 63% in children suspected of FbA. If CP is normal, probability of FbA is 25% and if PR is normal, probability is 14%. If CP is pathologic, probability of FbA is 69-76% with presence of cough (LR = 1.32) or dyspnea (LR = 1.84) or localized crackles (LR = 1.5). Probability is 81-88% if cyanosis (LR = 4.8) or decreased breaths sounds (LR = 4.3) or asymetric auscultation (LR = 2.9) or localized wheezing (LR = 2.5) are present. When CP is anormal and PR show mediatinal shift (LR = 100), pneumomediatin (LR = 100), radio opaque foreign body (LR = 100), lobar distention (LR = 4), atelectasis (LR = 2.5), inspiratory/expiratory abnormal (LR = 7), the probability of FbA is 96-100%. If CP is normal and PR is abnormal the probability is 40-100%. If CP is abnormal and PR is normal the probability is 55-75%. Conclusions: This rewiev of prospective studies demonstrates the importance of CP and PR and an algorithm can be proposed. When CP is abnormal with or without PR pathologic, the probability of FbA is high and bronchoscopy is indicated. When CP and PR are normal the probability of FbA is low and bronchoscopy is not necessary immediatly, observation should be proposed. This approach should be validated with prospective study.
Resumo:
Intermediate targets (IT) can modify the morphology of an entrance wound, the trajectory of the bullet, and contaminate the path with fragments or material from the target. The penetration into the body of big fragments or even of an entire IT is exceptional and only rarely reported in the literature. The interpretation of a gunshot wound after contact of the bullet with IT can sometimes be very tricky as the classical morphology can be missing. The presented case is a rare example of atypical entrance wound and path due to a surprising intermediate target of a gunshot fired against the head.
Resumo:
We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.
Resumo:
OBJECTIVE: To assess the molecular epidemiology and risk factors of predominant clones and sporadic strains of methicillin-resistant Staphylococcus aureus (MRSA) in Swiss hospitals and to compare them with European strains of epidemic clones. MATERIAL AND METHODS: One-year national survey of MRSA cases. Analysis of epidemiological and molecular typing data (PFGE) of MRSA strains. RESULTS: In 1997, 385 cases of MRSA were recorded in the five Swiss university hospitals and in 47 community hospitals. Half of the cases were found in Geneva hospitals where MRSA was already known to be endemic. Molecular typing of 288 isolates (one per case) showed that 186 (65%) belong to four predominant clones, three of which were mostly present in Geneva hospitals. In contrast, the fourth clone (85 cases) was found in 23 hospitals (in one to 16 cases per hospital). The remaining 35% of the strains were clustered into 62 pulsed field gel electrophoresis types. They accounted for one to five patients per hospital and were defined as sporadic. Multivariate analysis revealed no independent risk factors for harboring a predominant versus a sporadic strain, except that transfer from a foreign hospital increases the risk of harboring a sporadic strain (OR, 42; 95% CI, 5-360). CONCLUSION: While cases with predominant clones were due to the local spread of these clones, most sporadic cases appear to be due to the continuous introduction of new strains into the country. With the exception of a transfer from a hospital outside Switzerland, no difference in the clinical or epidemiological characteristics was observed between patients harboring a predominant clone and those with a sporadic strain.
Resumo:
Treatment of retinal detachment frequently uses biocompatible materials to obtain scleral buckling. These materials are not devoid of consequences on surrounding tissues. In 3 eyes enucleated for failure of surgical treatment using scleral buckling materials, the changes prompted by episcleral implants could be observed. The sclera underwent both an inversion of its curvature and a reduction of its thickness under the material, as well as an encapsulation of the material was observed. While a silicone sponge was used in part to encircle one of these eyes, its capsular inner surface was regular and smooth. In contrast, hydrogel implants used in the three eyes showed a peripheral fragmentation prompting in two of them a typical foreign body giant cell granulomatous reaction. Changes in scleral curvature and scleral thinning were observed reflecting the consequences of the buckling procedure. The capsule formation occurred as it does for any nonabsorbable matérial implanted in tissues. Degradation and fragmentation of the hydrogel material suscitated a granuloma in response to fragments. These hydrogel specific changes should be recognized on microscopic examination of slides of either capsule or eyes previously in contact with this implanted material. They attested of the instability of hydrogel after implantation.
Resumo:
BACKGROUND: Persisting metallic intraocular foreign bodies (IOFB) with a ferrous content have been associated with ocular siderosis and retinal degeneration. We describe two patients in whom a metallic IOFB containing iron was left embedded for many years in the choroid and sclera after having penetrated through the vitreous and the retina. HISTORY AND SIGNS: Two male patients, aged 41 and 48 years, presented with a metallic IOFB sustained during a work accident involving metal tools. THERAPY AND OUTCOME: For the first patient it was deemed unwise to operate, as the IOFB was also lodged very deeply in the choroid and sclera in the inferior temporal quadrant. The second patient underwent pars plana vitrectomy, but the IOFB could not be removed surgically as it was too deeply embedded in the sclera and choroid. After a period of 6 years (Case 1) and 4 years (Case 2) of follow-up, visual acuity remained at 1.0 and the IOFB was encased in a fibrotic capsule in both cases. Full-field and multifocal electroretinograms showed an inter-ocular asymmetry at baseline, which remained stable during the follow-up. CONCLUSIONS: Ocular siderosis may not develop in patients with a deeply embedded metallic IOFB. Regular monitoring of both visual function and the electroretinogram is mandatory when the IOFB is left inside the eye.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
Nuclei bind yeast vacuoles via nucleus-vacuole (NV) junctions. Under nutrient restriction, NV junctions invaginate and release vesicles filled with nuclear material into vacuoles, resulting in piecemeal microautophagy of the nucleus (PMN). We show that the electrochemical gradient across the vacuolar membrane promotes invagination of NV junctions. Existing invaginations persist independently of the gradient, but final release of PMN vesicles requires again V-ATPase activity. We find that NV junctions form a diffusion barrier on the vacuolar membrane that excludes V-ATPase but is enriched in the VTC complex and accessible to other membrane-integral proteins. V-ATPase exclusion depends on the NV junction proteins Nvj1p,Vac8p, and the electrochemical gradient. It also depends on factors of lipid metabolism, such as the oxysterol binding protein Osh1p and the enoyl-CoA reductase Tsc13p, which are enriched in NV junctions, and on Lag1p and Fen1p. Our observations suggest that NV junctions form in two separable steps: Nvj1p and Vac8p suffice to establish contact between the two membranes. The electrochemical potential and lipid-modifying enzymes are needed to establish the vacuolar diffusion barrier, invaginate NV junctions, and form PMN vesicles.