160 resultados para fluid shift

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Obstructive sleep apnea is associated with significantly increased cardiovascular morbidity and mortality. Fluid overload may promote obstructive sleep apnea in patients with ESRD through an overnight fluid shift from the legs to the neck soft tissues. Body fluid shift and severity of obstructive sleep apnea before and after hemodialysis were compared in patients with ESRD. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Seventeen patients with hemodialysis and moderate to severe obstructive sleep apnea were included. Polysomnographies were performed the night before and after hemodialysis to assess obstructive sleep apnea, and bioimpedance was used to measure fluid overload and leg fluid volume. RESULTS: The mean overnight rostral fluid shift was 1.27±0.41 L prehemodialysis; it correlated positively with fluid overload volume (r=0.39; P=0.02) and was significantly lower posthemodialysis (0.78±0.38 L; P<0.001). There was no significant difference in the mean obstructive apnea-hypopnea index before and after hemodialysis (46.8±22.0 versus 42.1±18.6 per hour; P=0.21), but obstructive apnea-hypopnea index was significantly lower posthemodialysis (-10.1±10.8 per hour) in the group of 12 patients, with a concomitant reduction of fluid overload compared with participants without change in fluid overload (obstructive apnea-hypopnea index +8.2±16.1 per hour; P<0.01). A lower fluid overload after hemodialysis was significantly correlated (r=0.49; P=0.04) with a lower obstructive apnea-hypopnea index. Fluid overload-assessed by bioimpedance-was the best predictor of the change in obstructive apnea-hypopnea index observed after hemodialysis (standardized r=-0.68; P=0.01) in multivariate regression analysis. CONCLUSIONS: Fluid overload influences overnight rostral fluid shift and obstructive sleep apnea severity in patients with ESRD undergoing intermittent hemodialysis. Although no benefit of hemodialysis on obstructive sleep apnea severity was observed in the whole group, the change in obstructive apnea-hypopnea index was significantly correlated with the change in fluid overload after hemodialysis. Moreover, the subgroup with lower fluid overload posthemodialysis showed a significantly lower obstructive sleep apnea severity, which provides a strong incentive to further study whether optimizing fluid status in patients with obstructive sleep apnea and ESRD will improve the obstructive apnea-hypopnea index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE: A dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis is a well-documented neurobiological finding in major depression. Moreover, clinically effective therapy with antidepressant drugs may normalize the HPA axis activity. OBJECTIVE: The aim of this study was to test whether citalopram (R/S-CIT) affects the function of the HPA axis in patients with major depression (DSM IV). METHODS: Twenty depressed patients (11 women and 9 men) were challenged with a combined dexamethasone (DEX) suppression and corticotropin-releasing hormone (CRH) stimulation test (DEX/CRH test) following a placebo week and after 2, 4, and 16 weeks of 40 mg/day R/S-CIT treatment. RESULTS: The results show a time-dependent reduction of adrenocorticotrophic hormone (ACTH) and cortisol response during the DEX/CRH test both in treatment responders and nonresponders within 16 weeks. There was a significant relationship between post-DEX baseline cortisol levels (measured before administration of CRH) and severity of depression at pretreatment baseline. Multiple linear regression analyses were performed to identify the impact of psychopathology and hormonal stress responsiveness and R/S-CIT concentrations in plasma and cerebrospinal fluid (CSF). The magnitude of decrease in cortisol responsivity from pretreatment baseline to week 4 on drug [delta-area under the curve (AUC) cortisol] was a significant predictor (p<0.0001) of the degree of symptom improvement following 16 weeks on drug (i.e., decrease in HAM-D21 total score). The model demonstrated that the interaction of CSF S-CIT concentrations and clinical improvement was the most powerful predictor of AUC cortisol responsiveness. CONCLUSION: The present study shows that decreased AUC cortisol was highly associated with S-CIT concentrations in plasma and CSF. Therefore, our data suggest that the CSF or plasma S-CIT concentrations rather than the R/S-CIT dose should be considered as an indicator of the selective serotonergic reuptake inhibitors (SSRIs) effect on HPA axis responsiveness as measured by AUC cortisol response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Bradykinin (BK) was shown to stimulate the production of physiologically active metabolites, blood-brain barrier disruption, and brain edema. The aim of this prospective study was to measure BK concentrations in blood and cerebrospinal fluid (CSF) of patients with traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), intracerebral hemorrhage (ICH), and ischemic stroke and to correlate BK levels with the extent of cerebral edema and intracranial pressure (ICP). Blood and CSF samples of 29 patients suffering from acute cerebral lesions (TBI, 7; SAH,: 10; ICH, 8; ischemic stroke, 4) were collected for up to 8 days after insult. Seven patients with lumbar drainage were used as controls. Edema (5-point scale), ICP, and the GCS (Glasgow Coma Score) at the time of sample withdrawal were correlated with BK concentrations. Though all plasma-BK samples were not significantly elevated, CSF-BK levels of all patients were significantly elevated in overall (n=73) and early (≤72 h) measurements (n=55; 4.3±6.9 and 5.6±8.9 fmol/mL), compared to 1.2±0.7 fmol/mL of controls (p=0.05 and 0.006). Within 72 h after ictus, patients suffering from TBI (p=0.01), ICH (p=0.001), and ischemic stroke (p=0.02) showed significant increases. CSF-BK concentrations correlated with extent of edema formation (r=0.53; p<0.001) and with ICP (r=0.49; p<0.001). Our results demonstrate that acute cerebral lesions are associated with increased CSF-BK levels. Especially after TBI, subarachnoid and intracerebral hemorrhage CSF-BK levels correlate with extent of edema evolution and ICP. BK-blocking agents may turn out to be effective remedies in brain injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Solid tumors are known to have an abnormal vasculature that limits the distribution of chemotherapy. We have recently shown that tumor vessel modulation by low-dose photodynamic therapy (L-PDT) could improve the uptake of macromolecular chemotherapeutic agents such as liposomal doxorubicin (Liporubicin) administered subsequently. However, how this occurs is unknown. Convection, the main mechanism for drug transport between the intravascular and extravascular spaces, is mostly related to interstitial fluid pressure (IFP) and tumor blood flow (TBF). Here, we determined the changes of tumor and surrounding lung IFP and TBF before, during, and after vascular L-PDT. We also evaluated the effect of these changes on the distribution of Liporubicin administered intravenously (IV) in a lung sarcoma metastasis model. MATERIALS AND METHODS: A syngeneic methylcholanthrene-induced sarcoma cell line was implanted subpleurally in the lung of Fischer rats. Tumor/surrounding lung IFP and TBF changes induced by L-PDT were determined using the wick-in-needle technique and laser Doppler flowmetry, respectively. The spatial distribution of Liporubicin in tumor and lung tissues following IV drug administration was then assessed in L-PDT-pretreated animals and controls (no L-PDT) by epifluorescence microscopy. RESULTS: L-PDT significantly decreased tumor but not lung IFP compared to controls (no L-PDT) without affecting TBF. These conditions were associated with a significant improvement in Liporubicin distribution in tumor tissues compared to controls (P < .05). DISCUSSION: L-PDT specifically enhanced convection in blood vessels of tumor but not of normal lung tissue, which was associated with a significant improvement of Liporubicin distribution in tumors compared to controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interplay of amyloid and mitochondrial function is considered crucial in the pathophysiology of Alzheimer's disease (AD). We tested the association of the putative marker of mitochondrial function N-acetylaspartate (NAA) as measured by proton magnetic resonance spectroscopy within the medial temporal lobe and cerebrospinal fluid amyoid-β42 (Aβ42), total Tau and pTau181. 109 patients were recruited in a multicenter study (40 mild AD patients, 14 non-AD dementia patients, 29 mild cognitive impairment (MCI) AD-type patients, 26 MCI of non-AD type patients). NAA correlated with Aβ42 within the AD group. Since the NAA concentration is coupled to neuronal mitochondrial function, the correlation between NAA and Aβ42 may reflect the interaction between disrupted mitochondrial pathways and amyloid production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metalworking fluid-associated hypersensitivity pneumonitis (MWF-HP) is a pulmonary disease caused by inhaling microorganisms present in the metalworking fluids used in the industrial sector. Mycobacterium immunogenum is the main etiological agent. Among the clinical, radiological and biological tools used for diagnosis, serological tests are important. The aim of this study was to identify immunogenic proteins in M. immunogenum and to use recombinant antigens for serological diagnosis of MWF-HP. Immunogenic proteins were detected by two-dimensional Western blot and candidate proteins were identified by mass spectrometry. Recombinant antigens were expressed in Escherichia coli and tested by enzyme-linked immunosorbent assay (ELISA) with the sera of 14 subjects with MWF-HP and 12 asymptomatic controls exposed to M. immunogenum. From the 350 spots visualized by two-dimensional gel electrophoresis with M. immunogenum extract, 6 immunogenic proteins were selected to be expressed as recombinant antigens. Acyl-CoA dehydrogenase antigen allowed for the best discrimination of MWF-HP cases against controls with an area under the receiver operating characteristics (ROC) curve of 0.930 (95% CI=0.820-1), a sensitivity of 100% and a specificity of 83% for the optimum threshold. Other recombinant antigens correspond to acyl-CoA dehydrogenase FadE, cytosol aminopeptidase, dihydrolipoyl dehydrogenase, serine hydroxymethyltransferase and superoxide dismutase. This is the first time that recombinant antigens have been used for the serodiagnosis of hypersensitivity pneumonitis. The availability of recombinant antigens makes it possible to develop standardized serological tests which in turn could simplify diagnosis, thus making it less invasive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Manifestations of external ventricular drain (EVD) - associated infections overlap with those of the underlying neurosurgical conditions. We analyzed characteristics of EVD-associated infections. METHODS: We included patients aged ≥18 years with EVD-associated infections from 1997 to 2008, using modified CDC criteria for nosocomial infections. Hospital charts were reviewed retrospectively and the in-hospital outcome was evaluated. RESULTS: Forty-eight patients with EVD-associated infections were included (median age, 52 years, range 20-74 years). The median EVD-indwelling time was 7 days (range, 1-39 days) and EVD-associated infection occurred 6 days after insertion (range, 1-17 days). In 23% of patients, meningitis occurred 1-10 days after EVD removal. Fever >38 °C was present in 79% of patients, but Glasgow Coma Scale (GCS) scores were reduced in only 29%, and headache, vomiting and/or neck stiffness were present in only 31%. The median cerebrospinal fluid (CSF) leukocyte count was higher at onset of EVD-associated infection than at EVD insertion (175 × 10(6)/l versus 46 × 10(6)/l, p = 0.021), but other CSF parameters did not differ significantly. The most commonly implicated organisms were coagulase-negative staphylococci (63%) and Propionibacterium acnes (15%). CONCLUSIONS: Fever and increased CSF leukocytes should raise the suspicion of EVD-associated infection, which may occur up to 10 days after removal of EVD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunocompetent microglia play an important role in the pathogenesis of Alzheimer's disease (AD). Antimicroglial antibodies in the cerebrospinal fluid (CSF) in clinically diagnosed AD patients have been previously recorded. Here, we report the results of the analysis of the CSF from 38 autopsy cases: 7 with definite AD; 14 with mild and 10 with moderate Alzheimer's type pathology; and 7 controls. Antimicroglial antibodies were identified in 70% of patients with definite AD, in 80% of patients with moderate and in 28% of patients with mild Alzheimer's type pathology. CSF antimicroglial antibodies were not observed in any of the control cases. The results show that CSF antimicroglial antibodies are present in the majority of patients with definite AD and also in cases with moderate Alzheimer's type changes. They may also indicate dysregulation of microglial function. Together with previous observations, these findings indicate that compromised immune defense mechanisms play an important role in the pathogenesis of AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Perioperative fluid accumulation determination is a challenge for the clinician. Bioelectrical impedance analysis (BIA) is a noninvasive method based on the electrical properties of tissues, which can assess body fluid compartments. The study aimed at assessing their changes in three types of surgery (thoracic, abdominal, and intracranial) requiring various regimens of fluid administration. DESIGN: Prospective descriptive trial. PATIENTS: A total of 26 patients scheduled for elective surgery were separated into three groups according to site of surgery: thoracic (n = 8), abdominal aortic (n = 8), and brain surgery (n = 10). SETTING: University teaching hospital. INTERVENTION: None. MEASUREMENTS: Whole body, segmental (arm, trunk, and legs) BIA at multiple frequency (0.5, 50, 100 kHz) was used to assess perioperative fluid accumulation after surgery. The fluid balances were calculated from the charts. RESULTS: The patients were aged 62+/-4 yrs. Fluid balances were 4.8+/-1.0 L, 4.1+/-0.5 L, and 1.9+/-0.3 L, respectively, in the three groups. In trunk surgery patients, fluid accumulation was detected as a drop in impedance in the operated area at all frequencies. In the operated area, there was an expansion of both intra- and extracellular compartments. A reduction in high frequencies' impedance in the legs was only detected after aortic surgery. Fluid accumulation and trunk impedance changes were strongly correlated. Neurosurgery only induced minor body fluid changes. CONCLUSIONS: Segmental BIA is able to detect and localize perioperative fluid accumulation. It may become a bedside tool to quantify and to localize fluid accumulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During fluorescence cystoscopy, it is observed that the acquired images are sometimes blurred by a greenish background originating from the bladder washout fluid. Several fluorophores are involved in this overall liquid fluorescence, and their exact origin and relative contributions remain unknown. In this study, the bladder washout fluid is sampled at different times during fluorescence cystoscopy examinations. In total, 32 samples from 12 patients are analyzed with a spectrofluorimeter (excitation range: 350-445 nm, emission range 380-700 nm). This study shows clearly that the position of the fluorescence peaks (excitation/emission wavelengths: 450/525 nm, 405/625 nm) and shoulder (440/525 nm) is reproducible between different patients. It also suggests that an excitation at wavelengths higher than 400 nm helps to suppress this solution background fluorescence. Additionally, the pH of the solution seems to influence the position of the fluorescence peaks, and this suggests that changing the pH of the examination liquid could help in avoiding the greenish background.